7P.25.8.275.0020 Finder Surge Protection Device SPD arresters 3ph

7P.25.8.275.0020 Finder Surge Protection Device SPD arresters 3ph

Finder 7P.25.8.275.0020 is a four-pole DIN rail-mounted Type 2 surge protection device for compatible 230/400 V AC three-phase TN-S electrical systems, featuring 275 V AC maximum continuous operating voltage, 20 kA nominal discharge current, 40 kA maximum discharge current, 1.2 kV voltage protection level, replaceable varistor cartridges and optical status indication without remote signalling.

SKU: 7P.25.8.275.0020Alt SKU: 7P2582750020MPN: 7P.25.8.275.0020
Price
List Price £155.97 ex VAT
Your Price (ex VAT) Save 25%
£116.98 25% OFF
You save £38.99 per unit
Manufacturer Lead Time Standard Manufacturer Lead Time 6-8 Weeks, Call For Express Delivery Options
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £116.98
Trade pricing is personalised to your account

Manufacturer Lead Time

£116.98

Why Choose the Finder 7P.25.8.275.0020 Type 2 Three-Phase Surge Protection Device?

The Finder 7P.25.8.275.0020 is a professional four-pole Type 2 surge protection device (SPD) designed to protect three-phase electrical installations against transient overvoltages caused by induced lightning surges and electrical switching operations. Part of the trusted Finder Series 7P, this DIN rail-mounted surge arrester provides protection for three-phase TN-S electrical distribution systems with separate neutral and protective earth conductors.

Engineered for standard 230/400 V AC three-phase electrical systems, the Finder 7P.25.8.275.0020 features a 275 V AC maximum continuous operating voltage (Uc), a 20 kA nominal discharge current (In) and a 40 kA maximum discharge current (Imax), measured using an 8/20 µs surge waveform. Its 1.2 kV voltage protection level (Up) helps limit transient overvoltages reaching connected equipment when the SPD is correctly selected, installed and coordinated with the electrical system.

The device incorporates four replaceable metal oxide varistor protection modules and integrated visual status indicators to simplify inspection and maintenance. Its compact four-module DIN rail construction, IP20 protection rating and wide operating temperature range make it suitable for industrial distribution boards, commercial electrical installations and three-phase automation systems. The 7P.25.8.275.0020 is the version without a remote signalling contact, making it a practical choice where local visual inspection is sufficient.

Key Advantages

  • Type 2 surge protection helps protect electrical equipment against induced lightning surges and switching transients.
  • Four-pole 3P+N configuration provides surge protection for three-phase TN-S electrical systems.
  • Suitable for 230/400 V AC three-phase installations commonly used in commercial and industrial electrical distribution.
  • 275 V AC maximum continuous operating voltage supports correct operation on compatible mains supplies.
  • 20 kA nominal discharge current provides substantial surge-handling capability.
  • 40 kA maximum discharge current supports protection against higher-energy transient events.
  • 1.2 kV voltage protection level helps limit residual surge voltage.
  • Four metal oxide varistor protection elements provide surge protection between L1, L2, L3, N and protective earth.
  • Replaceable varistor cartridges support straightforward maintenance without replacing the complete SPD assembly.
  • Visual protection status indicators enable quick identification of cartridges requiring replacement.
  • Compact four-module DIN rail format saves installation space inside electrical distribution boards.
  • 35 mm DIN rail mounting supports convenient installation in standard electrical enclosures.
  • −40 to +80 °C operating temperature range supports demanding industrial environments.
  • IP20 protection rating for installation inside suitable electrical cabinets.

Key Features

  • Finder Series 7P surge protection device.
  • 7P.25 four-pole Type 2 SPD configuration.
  • Three-phase plus neutral protection for TN-S systems.
  • Four metal oxide varistor (MOV) protection elements.
  • 230/400 V AC nominal three-phase system voltage.
  • 275 V AC maximum continuous operating voltage (Uc).
  • 350 V DC maximum continuous operating voltage characteristic.
  • 20 kA nominal discharge current (In) using an 8/20 µs waveform.
  • 40 kA maximum discharge current (Imax) using an 8/20 µs waveform.
  • 1.2 kV voltage protection level (Up).
  • 1.2 kV neutral-to-earth voltage protection level.
  • Replaceable varistor protection cartridges.
  • Optical varistor status indication for identifying protective elements requiring replacement.
  • No integrated remote signalling contact on this model.
  • 35 mm DIN rail mounting in accordance with EN 60715.
  • Four modular spacing units with approximately 71.8 mm overall width.
  • IP20 ingress protection rating.
  • −40 to +80 °C operating temperature range.
  • 50 kA short-circuit current rating (Isccr) under specified installation conditions.
  • Maximum associated backup fuse of 160 A, subject to manufacturer's coordination requirements.
  • IEC/EN 61643-11 Type 2 surge protection classification.

Reliable Type 2 Surge Protection for Three-Phase TN-S Systems

Three-phase electrical installations can be exposed to transient overvoltages caused by lightning activity, switching operations, inductive loads and disturbances within the electrical supply network. Although these voltage spikes are often extremely short, they can damage electronic equipment, interrupt industrial processes and reduce the reliability of connected electrical systems.

The Finder 7P.25.8.275.0020 Type 2 surge arrester is designed to help protect compatible 230/400 V AC three-phase TN-S systems. Its four-pole configuration provides protection for the three phase conductors and neutral relative to protective earth, helping limit transient voltages across the electrical installation.

The device uses metal oxide varistor technology, which responds to transient overvoltages by becoming conductive and diverting surge current through the intended protective path. With a 20 kA nominal discharge current, 40 kA maximum discharge current and 1.2 kV voltage protection level, the SPD provides defined surge protection characteristics for properly designed electrical distribution systems.

The Finder 7P.25.8.275.0020 is particularly suitable for installation in three-phase distribution boards where Type 2 protection is required downstream of the main electrical supply or as part of a coordinated surge protection arrangement. It is typically installed at the boundary between lightning protection zones LPZ 1 and LPZ 2, or at a higher protection zone, depending on the overall electrical installation design.

Effective surge protection depends on more than the SPD rating alone. The installation must also account for the earthing arrangement, upstream protective devices, connection lengths and coordination with any other surge protection devices. Installation should be carried out by a qualified electrical professional in accordance with Finder's instructions and applicable electrical regulations.

Replaceable Varistor Modules for Convenient Maintenance

Surge protection devices are exposed to repeated transient events throughout their operating life. Over time, these events can degrade the protective elements, eventually requiring replacement to maintain effective surge protection.

The Finder 7P.25.8.275.0020 incorporates four replaceable varistor cartridges, allowing maintenance personnel to replace individual protection elements without changing the complete SPD base, provided the base remains serviceable and the correct replacement modules are used.

Each protective element includes optical status indication. A red indication in the status window identifies a varistor cartridge requiring replacement, helping maintenance teams assess the condition of the installed SPD during routine inspections.

This model is supplied without a remote signalling contact. It is therefore well suited to installations where local inspection of surge protection status is sufficient and external monitoring through a building management system or PLC is not required.

Typical Applications

  • 230/400 V AC three-phase TN-S electrical distribution systems.
  • Industrial electrical distribution boards and switchgear assemblies.
  • Commercial building three-phase electrical installations.
  • Industrial automation and PLC control cabinets.
  • Manufacturing equipment and machinery electrical supplies.
  • Motor control centres and industrial process installations.
  • Building services electrical distribution systems.
  • Electrical installations exposed to induced lightning surges.
  • Three-phase power systems requiring protection against switching transients.
  • Industrial and commercial facilities using separate neutral and protective earth conductors.
  • DIN rail-mounted surge protection in electrical distribution enclosures.
  • Maintenance-friendly electrical installations using replaceable SPD cartridges.

Technical Specifications

Manufacturer Finder
Series 7P Surge Protection Devices
Model 7P.25.8.275.0020
Product type Three-phase Type 2 surge protection device
SPD classification Type 2
Number of poles 4 (3P+N)
Electrical configuration Three-phase plus neutral
Suitable earthing arrangement TN-S
Protection arrangement L1-PE, L2-PE, L3-PE and N-PE
Protection technology Four metal oxide varistors (MOV)
Nominal system voltage (Un) 230/400 V AC
Nominal phase-to-neutral voltage 230 V AC
Maximum continuous operating voltage (Uc), AC 275 V AC
Maximum continuous operating voltage, DC characteristic 350 V DC
Nominal discharge current (In) 20 kA (8/20 µs)
Maximum discharge current (Imax) 40 kA (8/20 µs)
Voltage protection level (Up) 1.2 kV
Neutral-to-earth voltage protection level 1.2 kV
Short-circuit current rating (Isccr) 50 kA, subject to specified installation conditions
Maximum associated backup fuse 160 A, subject to manufacturer coordination requirements
Integrated short-circuit protection No
Integrated backup fuse No
Protection elements Replaceable varistor cartridges
Local status indication Optical varistor status indicators
Integrated remote signalling contact No
Mounting method DIN rail
DIN rail size 35 mm
DIN rail standard EN 60715
Installation space 4 modular spacing units
Overall width Approximately 71.8 mm
Maximum rigid conductor cross-section 35 mm²
Maximum flexible conductor cross-section 25 mm²
Ingress protection IP20
Operating temperature −40 to +80 °C
Applicable standard IEC/EN 61643-11
Typical installation location LPZ 1 / LPZ 2 boundary or higher protection zone
EAN / GTIN 8012823398150

Frequently Asked Questions

What is the Finder 7P.25.8.275.0020 used for?

The Finder 7P.25.8.275.0020 is a four-pole Type 2 surge protection device designed to protect compatible three-phase TN-S electrical installations against transient overvoltages caused by induced lightning surges and electrical switching operations.

Is the Finder 7P.25.8.275.0020 a complete surge protection device?

Yes. The 7P.25.8.275.0020 is a complete DIN rail-mounted Type 2 surge protection assembly incorporating four replaceable varistor protection modules and optical protection status indication.

Which electrical earthing systems are suitable for the Finder 7P.25.8.275.0020?

The Finder 7P.25.8.275.0020 is designed for compatible three-phase TN-S electrical systems with separate neutral and protective earth conductors. The installation earthing arrangement must be verified before selecting the SPD.

What is the maximum continuous operating voltage of this surge protector?

The Finder 7P.25.8.275.0020 has a maximum continuous operating voltage (Uc) of 275 V AC and is designed for compatible 230/400 V AC three-phase electrical systems.

What is the nominal discharge current of the Finder 7P.25.8.275.0020?

The device has a 20 kA nominal discharge current (In), measured using the standard 8/20 µs surge current waveform.

What is the maximum discharge current of this Type 2 SPD?

The Finder 7P.25.8.275.0020 has a 40 kA maximum discharge current (Imax), measured using an 8/20 µs surge waveform.

What is the voltage protection level of the Finder 7P.25.8.275.0020?

The SPD has a specified 1.2 kV voltage protection level (Up), including a 1.2 kV neutral-to-earth protection level, indicating its surge voltage limitation performance under the applicable test conditions.

Does the Finder 7P.25.8.275.0020 have a remote signalling contact?

No. The Finder 7P.25.8.275.0020 does not include an integrated remote signalling contact. Protection status is monitored locally using the optical indicators on the varistor cartridges.

Does this surge protection device have visual status indicators?

Yes. The Finder 7P.25.8.275.0020 incorporates optical varistor status indicators. A red indication in a status window identifies a protective cartridge that requires replacement.

Can the varistor cartridges be replaced without changing the complete SPD?

Yes. The replaceable varistor modules allow individual protection cartridges to be changed while retaining the existing SPD base, provided the base remains serviceable and the correct Finder replacement modules are used.

How is the Finder 7P.25.8.275.0020 installed?

The device mounts onto a standard 35 mm DIN rail in accordance with EN 60715. It occupies four modular spacing units, measures approximately 71.8 mm wide and should be installed inside a suitable electrical enclosure.

Can the Finder 7P.25.8.275.0020 be used on a 230/400 V AC three-phase supply?

Yes. The Finder 7P.25.8.275.0020 is designed for compatible 230/400 V AC three-phase TN-S systems, with a maximum continuous operating voltage of 275 V AC. Correct selection and installation must be confirmed against the electrical system requirements.

What is the operating temperature range of this surge protection device?

The Finder 7P.25.8.275.0020 is designed for ambient operating temperatures from −40 to +80 °C, supporting use in a wide range of industrial and commercial electrical installations.

What is the difference between the Finder 7P.24.8.275.0020 and 7P.25.8.275.0020?

Both devices are Type 2 surge protection assemblies for compatible three-phase installations with a neutral conductor. The 7P.24.8.275.0020 uses varistor protection for the three phase conductors and a spark gap between neutral and protective earth, while the 7P.25.8.275.0020 uses four varistor protection elements and is intended for TN-S systems.

Trusted by Electrical Installation and Industrial Automation Professionals Worldwide

Finder Series 7P surge protection devices provide practical, modular solutions for protecting electrical installations against transient overvoltages. Combining four-pole metal oxide varistor technology, replaceable protection cartridges and clear visual status indication, the Finder 7P.25.8.275.0020 offers dependable Type 2 surge protection for compatible 230/400 V AC three-phase TN-S electrical distribution systems.