Finder 7P.24.8.275.0020 is a Type 2 three-phase surge protection device for TN-S and TT systems, featuring a 3+1 varistor and spark-gap configuration, 275 V AC maximum continuous operating voltage, 20 kA nominal discharge current, 40 kA maximum discharge current and replaceable protection modules.
£124.79
The Finder 7P.24.8.275.0020 is a Type 2 three-phase surge protection device (SPD) designed to protect low-voltage electrical installations against transient overvoltages caused by lightning-induced disturbances and electrical switching operations. Part of the Finder 7P Series, this surge arrester features a 3+1 protection configuration comprising three metal oxide varistors and one gas discharge spark gap, making it suitable for compatible TN-S and TT electrical distribution systems.
Designed for 230/400 V AC three-phase installations, the Finder 7P.24.8.275.0020 features a 275 V AC maximum continuous operating voltage (Uc), a 20 kA nominal discharge current (In) and a 40 kA maximum discharge current (Imax). Its protection arrangement helps limit transient overvoltages reaching connected electrical equipment, including power supplies, automation controllers, electronic switching equipment and industrial machinery.
The device incorporates replaceable varistor and spark-gap modules, visual protection status indication and a compact four-module housing. With 35 mm DIN rail mounting, IP20 protection and a wide operating temperature range, it provides a practical surge protection solution for industrial switchboards, commercial distribution boards and building electrical infrastructure. This specific .0020 version does not include a remote signalling contact.
The Finder 7P.24.8.275.0020 provides Type 2 transient overvoltage protection using a 3+1 circuit arrangement. Three metal oxide varistors are connected between the phase conductors and neutral, while a gas discharge spark gap provides protection between neutral and protective earth. This configuration is designed for compatible TN-S and TT electrical installations.
During a transient overvoltage event, the varistors become conductive and divert surge energy through the protective circuit. The gas discharge element provides the neutral-to-earth protection path, helping manage surge currents while supporting the intended earthing arrangement.
With a 20 kA nominal discharge current and 40 kA maximum discharge current, the device is suitable for electrical installations requiring protection against induced lightning surges and switching disturbances. Its 1.2 kV L–N and 1.5 kV N–PE voltage protection levels help reduce the voltage stress experienced by downstream equipment.
The Finder 7P.24.8.275.0020 incorporates replaceable surge protection modules, allowing individual varistor or spark-gap elements to be renewed when required. This modular design can simplify maintenance and reduce the need to replace the complete surge arrester assembly.
A visual varistor condition indicator provides local information about the protective element's operational status. The 7P.24.8.275.0020 is the version without a remote signalling contact, making it suitable for installations where local inspection is sufficient. Applications requiring remote SPD status monitoring should use an appropriately specified variant.
The device mounts onto a standard 35 mm DIN rail and occupies approximately four modular spaces. It is designed for installation at the boundary between lightning protection zones LPZ 1 and LPZ 2, or at other suitable locations determined by the electrical installation's protection strategy. Correct conductor routing, protective earthing and upstream overcurrent protection are essential for effective operation.
| Manufacturer | Finder |
|---|---|
| Series | 7P Series |
| Product family | 7P.24 |
| Model | 7P.24.8.275.0020 |
| Product type | Three-phase surge protection device |
| SPD classification | Type 2 |
| Protection configuration | 3+1 / 3+NPE |
| Number of protected conductors | 3 phases plus neutral |
| Compatible earthing arrangements | TN-S and TT |
| Protection technology | Three metal oxide varistors and one gas discharge spark gap |
| Phase protection paths | L1–N, L2–N and L3–N |
| Neutral protection path | N–PE |
| Nominal phase-to-neutral voltage | 230 V AC |
| Nominal three-phase system voltage | 230/400 V AC |
| Maximum continuous operating voltage (Uc), AC | 275 V AC |
| Maximum continuous operating voltage (Uc), DC | 350 V DC |
| Nominal discharge current (In), 8/20 µs | 20 kA |
| Maximum discharge current (Imax), 8/20 µs | 40 kA |
| Voltage protection level, L–N | 1.2 kV |
| Voltage protection level, N–PE | 1.5 kV |
| Short-circuit current rating (Isccr) | 50 kA |
| Maximum upstream backup fuse | 160 A for the specified parallel connection arrangement |
| Protection modules | Replaceable varistor and spark-gap cartridges |
| Local status indication | Optical varistor condition indicator |
| Remote signalling contact | Not included |
| Operating temperature | −40 to +80 °C |
| Ingress protection | IP20 |
| Mounting | 35 mm DIN rail |
| Mounting standard | EN 60715 |
| Housing width | Approximately 71.8 mm |
| Modular width | 4 DIN modules |
| Maximum rigid conductor cross-section | 35 mm² |
| Maximum flexible conductor cross-section | 25 mm² |
| Relevant standard | EN/IEC 61643-11 |
| EAN | 8012823398143 |
| Manufacturer part number | 7P.24.8.275.0020 |
The Finder 7P.24.8.275.0020 is a Type 2 three-phase surge protection device designed to protect compatible TN-S and TT electrical installations against transient overvoltages caused by induced lightning surges and electrical switching operations.
The device uses a 3+1 configuration comprising three metal oxide varistors connected between L1–N, L2–N and L3–N, plus one gas discharge spark gap connected between N–PE. This arrangement is suitable for compatible three-phase TN-S and TT systems.
The Finder 7P.24.8.275.0020 has a 275 V AC maximum continuous operating voltage, a 20 kA nominal discharge current and a 40 kA maximum discharge current, with discharge current ratings specified for an 8/20 µs surge waveform.
No. The 7P.24.8.275.0020 includes local visual varistor status indication but does not have an integrated remote signalling contact. A suitable alternative variant should be selected where remote monitoring is required.
Yes. The Finder 7P.24.8.275.0020 uses replaceable varistor and spark-gap modules. Replacement cartridges must be selected according to the manufacturer's specified part numbers and installed following appropriate electrical isolation and safety procedures.
Finder 7P Series surge protection devices provide dependable protection against transient overvoltages in industrial and commercial electrical installations. The 7P.24.8.275.0020 combines Type 2 protection, a three-varistor plus spark-gap configuration, 275 V AC maximum continuous operating voltage, 20 kA nominal discharge current, 40 kA maximum discharge current and replaceable modules for compatible three-phase TN-S and TT distribution systems.