7P.23.8.275.0020 Finder Surge Protection Device SPD arresters 3ph

7P.23.8.275.0020 Finder Surge Protection Device SPD arresters 3ph

Finder 7P.23.8.275.0020 is a three-pole Type 2 surge protection device for three-phase TN-C electrical systems, featuring 275 V AC maximum continuous operating voltage, 20 kA nominal discharge current, 40 kA maximum discharge current, replaceable varistor modules and local optical status indication without remote signalling.

SKU: 7P.23.8.275.0020Alt SKU: 7P2382750020MPN: 7P.23.8.275.0020
Price
List Price £116.25 ex VAT
Your Price (ex VAT) Save 25%
£87.19 25% OFF
You save £29.06 per unit
Manufacturer Lead Time Standard Manufacturer Lead Time 6-8 Weeks, Call For Express Delivery Options
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £87.19
Trade pricing is personalised to your account

Manufacturer Lead Time

£87.19

Why Choose the Finder 7P.23.8.275.0020 Type 2 Surge Protection Device?

The Finder 7P.23.8.275.0020 is a three-pole Type 2 surge protection device (SPD) designed to protect three-phase TN-C electrical distribution systems against transient overvoltages caused by switching operations and induced lightning surges. Part of the Finder 7P Series, this surge arrester features three metal oxide varistor protection paths and a compact DIN rail-mounted construction.

Designed for 230/400 V AC three-phase TN-C installations, the Finder 7P.23.8.275.0020 provides protection between the L1, L2 and L3 phase conductors and the combined protective earth and neutral (PEN) conductor. It has a 275 V AC maximum continuous operating voltage (Uc), a 20 kA nominal discharge current (In) and a 40 kA maximum discharge current (Imax), measured using the 8/20 µs surge waveform.

The device combines replaceable varistor cartridges with local optical condition indication, allowing maintenance personnel to identify when a protective module requires replacement. This .0020 version does not include a remote signalling contact, making it suitable for installations where local inspection is sufficient.

Key Advantages

  • Type 2 surge protection: Helps protect electrical equipment against induced lightning surges and switching transients.
  • Three-phase TN-C compatibility: Designed for systems using a combined protective earth and neutral conductor.
  • Three-pole protection: Provides varistor-based surge protection between L1, L2 and L3 and PEN.
  • 20 kA nominal discharge current: Offers substantial transient surge current handling capability.
  • 40 kA maximum discharge current: Supports protection against higher-energy surge events.
  • 275 V AC continuous operating voltage: Suitable for the specified 230/400 V AC distribution system.
  • 1.2 kV voltage protection level: Helps limit transient overvoltages reaching connected equipment.
  • Replaceable varistor modules: Simplifies maintenance without replacing the complete SPD assembly.
  • Visual status indication: Provides local Healthy/Replace indication of the protective elements.
  • 35 mm DIN rail mounting: Supports installation in standard electrical distribution enclosures.
  • Compact three-module construction: Occupies approximately 53.8 mm of DIN rail width.
  • Wide operating temperature range: Suitable for operation from −40 to +80 °C.
  • IP20 ingress protection: Suitable for installation within appropriately rated electrical enclosures.

Key Features

  • Finder 7P Series surge protection device.
  • Type 2 SPD classification.
  • Three-pole, 3+0 protection configuration.
  • Three metal oxide varistor protection paths.
  • Compatible with three-phase TN-C networks.
  • 230 V AC nominal phase voltage.
  • 275 V AC maximum continuous operating voltage (Uc).
  • 350 V DC maximum continuous operating voltage rating.
  • 20 kA nominal discharge current (In), 8/20 µs.
  • 40 kA maximum discharge current (Imax), 8/20 µs.
  • 1.2 kV voltage protection level (Up).
  • 0.9 kV voltage protection level at 5 kA.
  • 25 ns varistor response time.
  • Replaceable varistor cartridges.
  • Replacement module: Finder 7P.20.8.275.0020.
  • Optical Healthy/Replace status indication.
  • No remote signalling contact.
  • 35 mm DIN rail mounting according to EN 60715.
  • Three DIN-module construction.
  • IP20 ingress protection.
  • Compliance with EN 61643-11:2012.

Three-Phase TN-C Surge Protection for Electrical Distribution Systems

Electrical distribution networks can experience transient overvoltages resulting from lightning activity, switching operations and disturbances on the electrical supply. These short-duration voltage peaks can damage sensitive electronics, interrupt machinery operation and reduce the reliability of electrical installations. The Finder 7P.23.8.275.0020 Type 2 surge arrester is designed to limit these overvoltages in compatible three-phase TN-C systems.

Its three metal oxide varistor protection paths connect the phase conductors to the combined PEN conductor. During a transient surge event, the varistors respond rapidly to divert surge current and limit the voltage appearing across the protected circuit. The device's 20 kA nominal discharge current and 40 kA maximum discharge current support protection against induced lightning surges and electrical switching transients.

The Finder 7P.23.8.275.0020 is intended for installation at suitable surge protection zone boundaries, including LPZ 1 to LPZ 2, and can form part of a coordinated surge protection system. Its DIN rail-mounted construction makes it suitable for electrical distribution boards and control panels where space-efficient installation is required.

The replaceable Finder 7P.20.8.275.0020 varistor cartridges support straightforward maintenance when the visual Healthy/Replace indicator shows that a protective module has reached the end of its service life. The .0020 version provides local indication only; applications requiring remote status monitoring should use an appropriately specified Finder variant.

Installation consideration: This SPD is intended for TN-C systems with a combined PEN conductor and must not be assumed suitable for TT or TN-S installations with separate neutral and protective earth connections. Upstream protection, prospective short-circuit current, conductor lengths and coordination with other SPDs must be checked against the manufacturer's instructions. Installation should be carried out by a suitably qualified electrician.

Typical Applications

  • Three-phase TN-C electrical distribution networks.
  • Main and secondary electrical distribution boards.
  • Industrial electrical switchgear assemblies.
  • Commercial building electrical infrastructure.
  • Industrial automation and machinery supply protection.
  • Electrical installations using a combined PEN conductor.
  • Type 2 surge protection at LPZ 1 to LPZ 2 boundaries.
  • Electrical control panels and distribution cabinets.
  • Building services electrical distribution systems.
  • Lift and escalator electrical supply protection.
  • Road and tunnel lighting distribution infrastructure.
  • Industrial maintenance and electrical panel-building applications.

Technical Specifications

Manufacturer Finder
Series 7P Series
Model 7P.23.8.275.0020
Manufacturer part number 7P.23.8.275.0020
Product type Surge protection device
SPD classification Type 2
Electrical system Three-phase AC
Compatible earthing system TN-C
Number of poles 3
Protection configuration 3+0
Protection arrangement L1-PEN, L2-PEN, L3-PEN
Protection technology Metal oxide varistor
Nominal system voltage 230/400 V AC
Nominal phase voltage (Un) 230 V AC
Maximum continuous operating voltage (Uc), AC 275 V AC
Maximum continuous operating voltage (Uc), DC 350 V DC
Nominal discharge current (In), 8/20 µs 20 kA
Maximum discharge current (Imax), 8/20 µs 40 kA
Voltage protection level (Up) 1.2 kV
Voltage protection level at 5 kA (Up5) 0.9 kV
Response time 25 ns
Short-circuit current rating (ISCCR) 50 kA
Maximum upstream fuse rating 160 A gL/gG
Protection modules Replaceable varistor cartridges
Replacement module code 7P.20.8.275.0020
Local status indication Optical Healthy/Replace indicator
Remote signalling contact No
Mounting method 35 mm DIN rail
Mounting standard EN 60715
Modular width 3 DIN modules
Approximate overall width 53.8 mm
Solid conductor cross-section 1–35 mm²
Flexible conductor cross-section 1–25 mm²
Wire stripping length 12 mm
Terminal tightening torque 3 Nm
Operating ambient temperature −40 to +80 °C
Ingress protection IP20
Applicable standard EN 61643-11:2012
EAN 8012823400815

Frequently Asked Questions

What is the Finder 7P.23.8.275.0020 used for?

The Finder 7P.23.8.275.0020 is a three-pole Type 2 surge protection device designed to protect compatible three-phase TN-C electrical distribution systems against induced lightning surges and switching overvoltages.

Is the Finder 7P.23.8.275.0020 a Type 1 or Type 2 surge protector?

It is a Type 2 surge protection device, intended for protection against transient overvoltages caused by induced lightning activity and electrical switching operations.

Which earthing system is compatible with this SPD?

The Finder 7P.23.8.275.0020 is designed for three-phase TN-C systems with a combined protective earth and neutral (PEN) conductor. It provides protection between L1, L2 and L3 and PEN.

How many poles does the Finder 7P.23.8.275.0020 have?

The device has three poles and uses three varistor protection paths in a 3+0 configuration.

What is the maximum continuous operating voltage?

The Finder 7P.23.8.275.0020 has a maximum continuous operating voltage of 275 V AC, with a specified 350 V DC rating for the varistor protection paths.

What is the nominal discharge current of this surge arrester?

The device provides a 20 kA nominal discharge current (In), measured using the 8/20 µs surge waveform.

What is the maximum discharge current of the Finder 7P.23.8.275.0020?

The surge arrester has a 40 kA maximum discharge current (Imax), measured using the 8/20 µs surge waveform.

What voltage protection level does this SPD provide?

The Finder 7P.23.8.275.0020 has a specified 1.2 kV voltage protection level (Up) and a 0.9 kV protection level at 5 kA.

Does the Finder 7P.23.8.275.0020 have replaceable modules?

Yes. The device uses replaceable varistor cartridges. The specified replacement module is Finder 7P.20.8.275.0020.

Does the Finder 7P.23.8.275.0020 include remote signalling?

No. The 7P.23.8.275.0020 does not include a remote signalling contact. It provides local optical indication of varistor condition.

What is the difference between the Finder 7P.23.8.275.0020 and 7P.23.8.275.1020?

Both models are three-pole Type 2 surge protection devices for compatible TN-C systems. The 7P.23.8.275.0020 provides local optical indication without a remote signalling contact, while the 7P.23.8.275.1020 includes remote status signalling.

How is the Finder 7P.23.8.275.0020 mounted?

The surge arrester mounts on a 35 mm DIN rail according to EN 60715 and occupies approximately three DIN modules of width.

What upstream protection is required?

Finder specifies a maximum upstream fuse rating of 160 A gL/gG for the applicable protection arrangement. The actual backup protection must be selected according to the manufacturer's installation instructions and the electrical system design.

Can this SPD be used in a three-phase TN-S or TT installation?

This model is specifically designed for TN-C systems with a combined PEN conductor. Installations with separate neutral and protective earth conductors require an appropriately selected SPD, such as a compatible Finder 7P.24 or 7P.25 configuration.

What is the operating temperature range?

The Finder 7P.23.8.275.0020 is specified for operation between −40 and +80 °C.

Can the Finder 7P.23.8.275.0020 be installed outdoors?

The device has an IP20 ingress protection rating and should be installed inside an appropriately rated electrical enclosure. It is not suitable for unprotected outdoor mounting.

Trusted by Electrical Contractors, Panel Builders and Industrial Engineers

Finder 7P Series surge protection devices provide practical solutions for protecting electrical distribution systems against induced lightning surges and transient overvoltages. Combining Type 2 protection, three-pole TN-C compatibility, 275 V AC maximum continuous operating voltage, 20 kA nominal discharge current, 40 kA maximum discharge current, replaceable varistor modules and local optical status indication, the Finder 7P.23.8.275.0020 is suited to electrical contractors, industrial panel builders, consulting engineers and electrical maintenance professionals.