2CTB815710R5500 ABB OVR T1-T2 12.5-440s C QS Replacement Surge Protection Cartridge

2CTB815710R5500 ABB OVR T1-T2 12.5-440s C QS Replacement Surge Protection Cartridge

ABB OVR T1-T2 12.5-440s C QS is a pluggable replacement surge protection cartridge for compatible OVR T1-T2 QuickSafe devices, with 440 V AC maximum continuous operating voltage and 12.5 kA impulse-current capability.

SKU: 2CTB815710R5500MPN: 2CTB815710R5500
Price
List Price £148.43 ex VAT
Your Price (ex VAT) Save 25%
£111.32 25% OFF
You save £37.11 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £111.32
Trade pricing is personalised to your account

Manufacturer Lead Time

£111.32

Why Choose the ABB OVR T1-T2 12.5-440s C QS Replacement Cartridge?

The ABB OVR T1-T2 12.5-440s C QS, order code 2CTB815710R5500, is a replacement surge protection cartridge for compatible ABB OVR T1-T2 QuickSafe pluggable surge protective devices. Designed as part of ABB's combined Type 1 and Type 2 surge protection system, it restores the replaceable protection element without requiring the complete installed SPD base to be changed.

The cartridge is designed for compatible 440 V AC OVR T1-T2 QuickSafe assemblies and provides combined lightning-current and transient-overvoltage protection. Its plug-in format makes planned maintenance faster and helps reduce disruption when a protection cartridge reaches the end of its service life.

With a maximum continuous operating voltage (Uc) of 440 V AC and an impulse current (Iimp) of 12.5 kA for the 10/350 µs lightning-current waveform, the OVR T1-T2 12.5-440s C QS is engineered for demanding surge protection duties. QuickSafe technology provides clear condition indication and supports reliable end-of-life management in compatible ABB OVR installations.

Key Advantages

  • Genuine ABB replacement cartridge for compatible OVR T1-T2 QuickSafe surge protective devices.
  • Provides combined Type 1 and Type 2 surge protection when installed in the correct compatible base.
  • 12.5 kA impulse current (Iimp) capability for 10/350 µs lightning-current impulses.
  • 440 V AC maximum continuous operating voltage (Uc).
  • Plug-in construction allows the protection element to be replaced without changing the complete SPD assembly.
  • Supports rapid preventative and corrective maintenance of surge protection systems.
  • QuickSafe technology provides practical condition and end-of-life indication.
  • Helps restore surge protection after a compatible cartridge has reached the end of its service life.
  • Suitable for professional electrical distribution and control-panel applications.

Key Features

  • ABB OVR T1-T2 QuickSafe series.
  • Replacement surge protection cartridge.
  • Combined Type 1 + Type 2 protection element.
  • Maximum continuous operating voltage (Uc): 440 V AC.
  • Impulse current (Iimp, 10/350 µs): 12.5 kA.
  • Pluggable cartridge design for straightforward replacement.
  • QuickSafe condition indication for maintenance support.
  • Designed for use with compatible ABB OVR T1-T2 12.5-440s pluggable SPD assemblies.
  • Suitable for maintaining lightning-current and transient-overvoltage protection.
  • ABB order code 2CTB815710R5500 for precise replacement identification.

Reliable Replacement Protection for ABB OVR QuickSafe SPDs

Pluggable surge protective devices allow the active protection element to be replaced separately from the permanently wired base. The ABB OVR T1-T2 12.5-440s C QS provides this replaceable element for compatible 440 V AC OVR T1-T2 QuickSafe assemblies, helping restore combined Type 1 and Type 2 protection following end-of-life indication or scheduled maintenance.

Using the correct ABB replacement cartridge preserves the intended electrical characteristics and mechanical compatibility of the installed surge protection assembly. The plug-in design also reduces maintenance work because the existing compatible SPD base and its fixed wiring can remain installed while the cartridge is exchanged.

Typical Applications

  • Replacement cartridge for compatible ABB OVR T1-T2 12.5-440s SPDs.
  • Maintenance of main low-voltage electrical distribution boards.
  • Industrial control and power distribution panels.
  • Commercial and industrial electrical installations.
  • Buildings requiring combined Type 1 and Type 2 surge protection.
  • Preventative maintenance of ABB QuickSafe surge protection systems.
  • Replacement of an end-of-life compatible surge protection cartridge.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Replacement cartridge
Impulse Current Iimp (kA) 12.5 kA
Series OVR T1-T2 QuickSafe
ABB order code 2CTB815710R5500
Product type Replacement surge protection cartridge
SPD classification Type 1 + Type 2
Cartridge type Pluggable / replaceable
Maximum continuous operating voltage (Uc) 440 V AC
Impulse current (Iimp, 10/350 µs) 12.5 kA
Compatibility Compatible ABB OVR T1-T2 12.5-440s pluggable surge protective devices
Technology QuickSafe
Function Replacement lightning-current and transient-overvoltage protection element
ABB product group Surge Protection Devices

Frequently Asked Questions

What is the ABB OVR T1-T2 12.5-440s C QS?

It is a pluggable replacement surge protection cartridge for compatible ABB OVR T1-T2 QuickSafe surge protective devices, allowing the active protection element to be replaced without changing the complete compatible SPD assembly.

What is the maximum continuous operating voltage of the 2CTB815710R5500?

The OVR T1-T2 12.5-440s C QS has a maximum continuous operating voltage (Uc) of 440 V AC.

What impulse current is the cartridge designed for?

The cartridge has an impulse current (Iimp) rating of 12.5 kA for the 10/350 µs lightning-current waveform.

Is the OVR T1-T2 12.5-440s C QS a complete surge protective device?

No. It is the replaceable cartridge intended for installation in a compatible ABB OVR T1-T2 QuickSafe SPD base rather than a complete independently wired surge protective device.

Why use a genuine ABB replacement cartridge?

Using the specified ABB cartridge helps maintain the intended electrical performance, mechanical fit and coordinated Type 1 and Type 2 surge protection of the compatible OVR QuickSafe assembly.

Trusted Surge Protection from ABB

ABB OVR QuickSafe replacement cartridges provide a practical way to restore compatible pluggable surge protective devices, supporting efficient maintenance while preserving coordinated lightning-current and transient-overvoltage protection.