2CTB815710R2700 ABB OVR T1-T2 N 50-275s C QS Type 1+2 Surge Protection Cartridge

2CTB815710R2700 ABB OVR T1-T2 N 50-275s C QS Type 1+2 Surge Protection Cartridge

ABB OVR T1-T2 N 50-275s C QS is a combined Type 1+2 N-PE surge protection cartridge with 275 V AC maximum continuous operating voltage and 50 kA lightning impulse current for compatible ABB OVR QuickSafe surge protective devices.

SKU: 2CTB815710R2700MPN: 2CTB815710R2700
Price
List Price £206.81 ex VAT
Your Price (ex VAT) Save 25%
£155.11 25% OFF
You save £51.70 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £155.11
Trade pricing is personalised to your account

Manufacturer Lead Time

£155.11

Why Choose the ABB OVR T1-T2 N 50-275s C QS Surge Protection Cartridge?

The ABB OVR T1-T2 N 50-275s C QS is a high-performance combined Type 1+2 neutral surge protection cartridge designed for use with compatible ABB OVR QuickSafe surge protective devices. As part of the advanced ABB OVR QuickSafe surge protection range, it provides N-PE protection against lightning currents and transient overvoltages in low-voltage electrical installations.

Designed as a replaceable neutral protection cartridge, the OVR T1-T2 N 50-275s C QS enables the neutral-to-protective-earth protection element in compatible ABB OVR assemblies to be replaced without changing the complete surge protective device. This modular construction supports straightforward maintenance while retaining coordinated Type 1 and Type 2 protection within the installation.

With an impulse current (Iimp) of 50 kA using a 10/350 µs waveform and a 275 V AC maximum continuous operating voltage, the OVR T1-T2 N 50-275s C QS is designed for demanding N-PE lightning and surge protection applications. The cartridge is supplied under ABB order code 2CTB815710R2700.

Key Advantages

  • Combined Type 1+2 neutral surge protection cartridge.
  • Designed specifically for N-PE lightning current and surge protection.
  • 50 kA impulse current Iimp (10/350 µs) for high-energy lightning protection.
  • 275 V AC maximum continuous operating voltage.
  • ABB QuickSafe technology for dependable surge protection performance.
  • Replaceable cartridge format simplifies servicing of compatible ABB OVR assemblies.
  • Suitable for coordinated protection in low-voltage electrical distribution systems.
  • Compact modular construction for professional electrical installations.

Key Features

  • ABB OVR T1-T2 QuickSafe surge protection series.
  • Combined Type 1+2 protection technology.
  • N-PE neutral-to-protective-earth protection mode.
  • 50 kA Iimp lightning impulse current capability.
  • 275 V AC maximum continuous operating voltage (Uc).
  • Designed as a replaceable neutral cartridge.
  • Suitable for compatible ABB OVR QuickSafe surge protective device assemblies.
  • Designed to handle high-energy lightning currents as well as transient overvoltages.

Combined Lightning and Surge Protection for N-PE Applications

Combined Type 1+2 surge protection is designed to address both high-energy lightning currents and transient overvoltages within low-voltage electrical installations. Type 1 capability enables the protection system to handle lightning impulse currents characterised by a 10/350 µs waveform, while Type 2 protection helps limit lower-energy transient surges that could otherwise damage downstream electrical and electronic equipment.

The ABB OVR T1-T2 QuickSafe range provides modular protection for coordinated electrical installations. The OVR T1-T2 N 50-275s C QS serves as the N-PE protection cartridge in compatible assemblies, combining a high 50 kA lightning impulse current capability with replaceable construction for convenient maintenance.

Typical Applications

  • Replacement neutral cartridge for compatible ABB OVR QuickSafe surge protective devices.
  • N-PE lightning current and surge protection.
  • Main low-voltage electrical distribution boards.
  • Industrial electrical installations.
  • Commercial buildings and facilities.
  • Building services and infrastructure installations.
  • Installations requiring combined Type 1 and Type 2 protection.
  • Protection systems for sensitive electrical and electronic equipment.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Replacement cartridge
Impulse Current Iimp (kA) 50 kA
Series OVR T1-T2 QuickSafe
ABB order code 2CTB815710R2700
Product group Surge Protection Devices
Product type Combined Type 1+2 surge protection cartridge
Test class Type 1 + Type 2
Protection mode N-PE
Number of protected lines 1
Maximum continuous operating voltage (Uc) 275 V AC
Impulse current Iimp (10/350 µs) 50 kA
Replacement type Neutral protection cartridge
Construction Pluggable / replaceable module
Application Neutral-to-protective-earth lightning and surge protection

Frequently Asked Questions

What is the ABB OVR T1-T2 N 50-275s C QS used for?

This product is a combined Type 1+2 neutral surge protection cartridge designed to provide N-PE lightning current and transient overvoltage protection when installed in a compatible ABB OVR QuickSafe surge protective device.

What is the impulse current rating of the OVR T1-T2 N 50-275s C QS?

The cartridge has an impulse current Iimp of 50 kA using a 10/350 µs waveform, enabling it to handle high-energy lightning currents in suitable surge protection assemblies.

What is the maximum continuous operating voltage?

The ABB OVR T1-T2 N 50-275s C QS has a maximum continuous operating voltage Uc of 275 V AC.

What protection mode does this cartridge provide?

The OVR T1-T2 N 50-275s C QS provides N-PE neutral-to-protective-earth protection as part of a compatible coordinated surge protection assembly.

What is the ABB order code for the OVR T1-T2 N 50-275s C QS?

The ABB order code is 2CTB815710R2700.

Trusted ABB Lightning and Surge Protection Technology

ABB OVR QuickSafe combined Type 1+2 surge protection products are designed to protect low-voltage installations against lightning currents and transient overvoltages, providing coordinated protection for electrical and electronic equipment in industrial, commercial and infrastructure applications.