2CTB815710R1800 ABB OVR T1-T2 3L 12.5-275s P QS Combined Surge Protective Device

2CTB815710R1800 ABB OVR T1-T2 3L 12.5-275s P QS Combined Surge Protective Device

ABB OVR T1-T2 3L 12.5-275s P QS is a three-pole combined Type 1 and Type 2 pluggable surge protective device rated at 230/400 V AC with 12.5 kA impulse current, 80 kA maximum discharge current and a 1.1 kV protection level.

SKU: 2CTB815710R1800MPN: 2CTB815710R1800
Price
List Price £407.61 ex VAT
Your Price (ex VAT) Save 25%
£305.71 25% OFF
You save £101.90 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £305.71
Trade pricing is personalised to your account

Manufacturer Lead Time

£305.71

Why Choose the ABB OVR T1-T2 3L 12.5-275s P QS Surge Protective Device?

The ABB OVR T1-T2 3L 12.5-275s P QS, order code 2CTB815710R1800, is a combined Type 1 and Type 2 surge protective device (SPD) designed to protect three-phase low-voltage electrical installations against high-energy lightning currents and transient overvoltages. Part of the ABB OVR QuickSafe surge protection range, it combines Type 1 lightning-current protection with Type 2 overvoltage protection in a compact three-pole DIN-rail-mounted assembly.

The device protects L1, L2 and L3 and is rated for 230/400 V AC systems. Its pluggable construction enables protection modules to be replaced when required, while ABB QuickSafe technology incorporates an end-of-life indicator and patented Safety Reserve system to support preventive maintenance and dependable operation.

With a maximum continuous operating voltage (Uc) of 275 V AC, an impulse current (Iimp) of 12.5 kA using a 10/350 µs waveform, a maximum discharge current (Imax) of 80 kA and a nominal discharge current (In) of 30 kA, the OVR T1-T2 3L 12.5-275s P QS provides substantial surge-handling capability. Its low 1.1 kV voltage protection level (Up) helps limit the residual voltage presented to downstream electrical equipment.

Key Advantages

  • Combined Type 1 and Type 2 surge protection in one compact device.
  • 12.5 kA impulse current (Iimp) for 10/350 µs lightning-current impulses.
  • 80 kA maximum discharge current (Imax) for high transient-current capability.
  • 30 kA nominal discharge current (In) for 8/20 µs surge currents.
  • Low 1.1 kV voltage protection level (Up) helps protect downstream equipment.
  • 275 V AC maximum continuous operating voltage (Uc).
  • Three-pole design protects L1, L2 and L3 in three-phase installations.
  • Pluggable protection modules simplify servicing and replacement.
  • QuickSafe end-of-life indication and Safety Reserve support planned maintenance.

Key Features

  • ABB OVR T1-T2 QuickSafe surge protective device series.
  • Combined Type 1 + Type 2 SPD.
  • Three-pole (3L) configuration.
  • Nominal voltage (Un): 230/400 V AC.
  • Maximum continuous operating voltage (Uc): 275 V AC.
  • Impulse current (Iimp, 10/350 µs): 12.5 kA.
  • Maximum discharge current (Imax, 8/20 µs): 80 kA.
  • Nominal discharge current (In, 8/20 µs): 30 kA.
  • Voltage protection level (Up): 1.1 kV.
  • Combined spark-gap and varistor surge-protection technology.
  • Pluggable, replaceable protection modules.
  • QuickSafe end-of-life indication with Safety Reserve.
  • DIN-rail mounting for System pro M compact installations.
  • IP20 degree of protection.

Combined Lightning and Surge Protection for Three-Phase Systems

Type 1 surge protective devices are designed to discharge high-energy currents associated with lightning, while Type 2 devices protect against lower-energy transient overvoltages caused by indirect lightning effects and switching operations. The ABB OVR T1-T2 3L 12.5-275s P QS combines both functions, allowing it to provide coordinated protection at main or appropriate sub-distribution boards.

Its 1.1 kV protection level combines with high lightning-current and surge-current capability to help protect downstream installations. Pluggable modules simplify maintenance, while ABB's QuickSafe end-of-life indication and Safety Reserve system help maintenance personnel identify deterioration and plan replacement before complete loss of surge protection.

Typical Applications

  • Three-phase 230/400 V AC electrical distribution systems.
  • Main distribution boards requiring combined Type 1 and Type 2 protection.
  • Industrial control and power distribution panels.
  • Commercial and industrial buildings.
  • Buildings with external lightning protection systems.
  • Manufacturing and production facilities.
  • Electrical installations exposed to lightning-induced and switching overvoltages.

Technical Specifications

Tick the specs you need, then view products that match.

Remote Signal No
Device Type Surge protection device
SPD Type Type 1+2
Poles 3-pole
Earthing System TN-C
Impulse Current Iimp (kA) 12.5 kA
Series OVR T1-T2 QuickSafe
ABB order code 2CTB815710R1800
Product type Combined lightning-current and surge protective device (SPD)
SPD classification Type 1 + Type 2
Configuration 3L
Protected lines L1, L2, L3
Number of modules 3
Nominal voltage (Un) 230/400 V AC
Maximum continuous operating voltage (Uc) 275 V AC
Impulse current (Iimp, 10/350 µs) 12.5 kA
Maximum discharge current (Imax, 8/20 µs) 80 kA
Nominal discharge current (In, 8/20 µs) 30 kA
Voltage protection level (Up) 1.1 kV
Technology Spark gap / varistor
Protection modules Pluggable / replaceable
Safety Reserve Yes
End-of-life indication Yes, QuickSafe indicator
Remote auxiliary contact No
Protection rating IP20
Operating temperature −40 to +80 °C
Storage temperature −40 to +80 °C
Maximum solid Cu conductor 50 mm²
Maximum flexible Cu conductor 35 mm²
Tightening torque 3.5 Nm
Mounting type DIN rail
Width 53.4 mm
Weight approx. 0.45 kg
Standard EN / IEC 61643-11
EAN 3660308524980

Frequently Asked Questions

What is the ABB OVR T1-T2 3L 12.5-275s P QS used for?

It is a combined Type 1 and Type 2 surge protective device designed to protect three-phase electrical installations against high-energy lightning currents and transient overvoltages.

What surge currents can the 2CTB815710R1800 handle?

It has an impulse current (Iimp) of 12.5 kA for a 10/350 µs waveform, a nominal discharge current (In) of 30 kA and a maximum discharge current (Imax) of 80 kA for an 8/20 µs waveform.

What is the voltage protection level of this ABB SPD?

The OVR T1-T2 3L 12.5-275s P QS has a voltage protection level (Up) of 1.1 kV.

Are the surge protection modules replaceable?

Yes. The device uses pluggable, replaceable protection modules and incorporates ABB QuickSafe end-of-life indication and Safety Reserve technology to support maintenance.

Does the 2CTB815710R1800 have a remote signalling contact?

No. This P QS version does not incorporate an auxiliary remote signalling contact; the corresponding TS variant is used where remote status signalling is required.

Trusted Surge Protection from ABB

ABB OVR QuickSafe surge protective devices combine high lightning-current capability, low residual voltage, pluggable construction and practical condition indication to provide dependable protection for modern low-voltage electrical installations.