2CTB815710R1300 ABB OVR T1-T2 1N 12.5-275s P QS Type 1+2 Surge Protective Device

2CTB815710R1300 ABB OVR T1-T2 1N 12.5-275s P QS Type 1+2 Surge Protective Device

ABB OVR T1-T2 1N 12.5-275s P QS is a 1+1 combined Type 1+2 surge protective device for single-phase 230 V AC installations with 275 V AC maximum continuous operating voltage and 12.5 kA impulse current per pole.

SKU: 2CTB815710R1300MPN: 2CTB815710R1300
Price
List Price £277.06 ex VAT
Your Price (ex VAT) Save 25%
£207.80 25% OFF
You save £69.27 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £207.80
Trade pricing is personalised to your account

Manufacturer Lead Time

£207.80

Why Choose the ABB OVR T1-T2 1N 12.5-275s P QS Surge Protective Device?

The ABB OVR T1-T2 1N 12.5-275s P QS is a high-performance combined Type 1+2 surge protective device (SPD) designed to protect single-phase low-voltage electrical installations against lightning currents and transient overvoltages. As part of the advanced ABB OVR QuickSafe surge protection range, it combines Type 1 lightning current protection and Type 2 surge protection in a compact 1+1 configuration.

Designed for single-phase installations with neutral, the OVR T1-T2 1N 12.5-275s P QS provides coordinated protection between line, neutral and protective earth. Its pluggable construction allows straightforward servicing and replacement of protection modules, while ABB QuickSafe technology provides dependable status indication and enhanced protection throughout the service life of the device.

With an impulse current (Iimp) of 12.5 kA per pole using a 10/350 µs waveform, maximum discharge current (Imax) of 80 kA using an 8/20 µs waveform and 275 V AC maximum continuous operating voltage on the line protection path, the OVR T1-T2 1N 12.5-275s P QS provides robust protection for single-phase 230 V AC electrical systems. The device is supplied under ABB order code 2CTB815710R1300.

Key Advantages

  • Combined Type 1+2 surge protective device for lightning current and transient overvoltage protection.
  • 1+1 configuration for single-phase electrical systems with neutral.
  • 12.5 kA impulse current Iimp (10/350 µs) per pole.
  • 80 kA maximum discharge current Imax (8/20 µs).
  • 275 V AC maximum continuous operating voltage on the line protection path.
  • Designed for 230 V AC single-phase installations.
  • ABB QuickSafe technology for reliable surge protection performance and status indication.
  • Pluggable protection modules simplify inspection, servicing and replacement.
  • DIN-rail mounting enables straightforward installation in electrical distribution boards.

Key Features

  • ABB OVR T1-T2 QuickSafe surge protection series.
  • Combined Type 1+2 surge protective device.
  • 1+1 protection configuration for line, neutral and protective earth.
  • 12.5 kA Iimp per pole lightning impulse current capability.
  • 80 kA Imax maximum discharge current.
  • 275 V AC maximum continuous operating voltage (Uc) for the L-N protection path.
  • Designed for 230 V AC nominal systems.
  • Pluggable construction for convenient maintenance.
  • Visual status indication for straightforward inspection.
  • Compact DIN-rail format for low-voltage distribution equipment.

Combined Lightning and Surge Protection for Single-Phase Installations

Combined Type 1+2 surge protective devices provide protection against both high-energy lightning currents and transient overvoltages. Type 1 capability enables the SPD to discharge lightning impulse currents characterised by a 10/350 µs waveform, while Type 2 performance limits surge currents characterised by an 8/20 µs waveform, helping protect downstream electrical and electronic equipment.

The ABB OVR T1-T2 QuickSafe range is designed for coordinated protection of low-voltage installations. The OVR T1-T2 1N 12.5-275s P QS combines line-to-neutral and neutral-to-earth protection in a 1+1 arrangement, making it suitable for single-phase installations where coordinated lightning and surge protection is required at the electrical distribution board.

Typical Applications

  • Single-phase low-voltage electrical distribution boards.
  • 230 V AC electrical installations.
  • Residential and commercial electrical distribution systems.
  • Industrial single-phase electrical circuits.
  • Installations requiring combined lightning current and surge protection.
  • Building services and infrastructure systems.
  • Machine and automation electrical panels.
  • Protection of sensitive electrical and electronic equipment.

Technical Specifications

Tick the specs you need, then view products that match.

Remote Signal No
Device Type Surge protection device
SPD Type Type 1+2
Poles 1-pole + N
Earthing System TN-S, TT
Impulse Current Iimp (kA) 12.5 kA
Series OVR T1-T2 QuickSafe
ABB order code 2CTB815710R1300
Product group Surge Protection Devices
Product type Combined Type 1+2 surge protective device
Test class Type 1 + Type 2
Configuration 1+1
Application Single-phase system with neutral
Nominal system voltage 230 V AC
Maximum continuous operating voltage Uc (L-N) 275 V AC
Impulse current Iimp (10/350 µs) 12.5 kA per pole
Maximum discharge current Imax (8/20 µs) 80 kA
Construction Pluggable
Status indication Visual
Mounting type DIN rail

Frequently Asked Questions

What is the ABB OVR T1-T2 1N 12.5-275s P QS used for?

This device provides combined Type 1+2 lightning current and surge protection for single-phase low-voltage electrical installations, helping protect downstream equipment against lightning effects and transient overvoltages.

What is the impulse current rating of the OVR T1-T2 1N 12.5-275s P QS?

The device provides an impulse current Iimp of 12.5 kA per pole using a 10/350 µs waveform, providing Type 1 lightning current protection alongside Type 2 surge protection.

What supply system is the OVR T1-T2 1N 12.5-275s P QS designed for?

The device uses a 1+1 protection configuration designed for single-phase electrical systems with neutral, including nominal 230 V AC installations.

What is the maximum continuous operating voltage?

The line-to-neutral protection path of the ABB OVR T1-T2 1N 12.5-275s P QS has a maximum continuous operating voltage Uc of 275 V AC.

What is the ABB order code for the OVR T1-T2 1N 12.5-275s P QS?

The ABB order code is 2CTB815710R1300.

Trusted ABB Lightning and Surge Protection Technology

ABB OVR QuickSafe combined Type 1+2 surge protective devices are designed to protect low-voltage installations against lightning currents and transient overvoltages, providing coordinated protection for electrical and electronic equipment in residential, commercial, industrial and infrastructure applications.