2CTB815710R1200 ABB OVR T1-T2 12.5-275s P QS Type 1+2 Surge Protective Device

2CTB815710R1200 ABB OVR T1-T2 12.5-275s P QS Type 1+2 Surge Protective Device

ABB OVR T1-T2 12.5-275s P QS is a single-pole combined Type 1+2 surge protective device for 230 V AC installations with 275 V AC maximum continuous operating voltage, 12.5 kA impulse current and 80 kA maximum discharge current.

SKU: 2CTB815710R1200MPN: 2CTB815710R1200
Price
List Price £169.03 ex VAT
Your Price (ex VAT) Save 25%
£126.77 25% OFF
You save £42.26 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £126.77
Trade pricing is personalised to your account

Manufacturer Lead Time

£126.77

Why Choose the ABB OVR T1-T2 12.5-275s P QS Surge Protective Device?

The ABB OVR T1-T2 12.5-275s P QS is a high-performance combined Type 1+2 surge protective device (SPD) designed to protect low-voltage electrical installations against lightning currents and transient overvoltages. As part of the advanced ABB OVR QuickSafe surge protection range, it combines Type 1 lightning current protection and Type 2 surge protection in a compact single-pole device.

Designed for use in suitable TT, TN-S and TN-C distribution systems, the OVR T1-T2 12.5-275s P QS uses spark-gap and varistor technology with a replaceable protection module and ABB QuickSafe end-of-life indication. Its safety reserve and pluggable construction help simplify maintenance while providing dependable protection for industrial, commercial and building electrical installations.

With an impulse current (Iimp) of 12.5 kA using a 10/350 µs waveform, maximum discharge current (Imax) of 80 kA using an 8/20 µs waveform and 275 V AC maximum continuous operating voltage, the OVR T1-T2 12.5-275s P QS provides robust protection for 230 V AC systems. The device is supplied under ABB order code 2CTB815710R1200.

Key Advantages

  • Combined Type 1+2 surge protective device for lightning current and transient overvoltage protection.
  • 12.5 kA impulse current Iimp (10/350 µs).
  • 80 kA maximum discharge current Imax (8/20 µs).
  • 30 kA nominal discharge current In (8/20 µs).
  • 275 V AC maximum continuous operating voltage.
  • 1.1 kV voltage protection level (Up).
  • ABB QuickSafe end-of-life indication and safety reserve.
  • Replaceable protection module simplifies servicing and maintenance.
  • Compact single-module DIN-rail design for electrical distribution boards.

Key Features

  • ABB OVR T1-T2 QuickSafe surge protection series.
  • Combined Type 1+2 surge protective device.
  • Single-pole L1 configuration.
  • 12.5 kA Iimp lightning impulse current capability.
  • 80 kA Imax maximum discharge current.
  • 30 kA In nominal discharge current.
  • 230 V AC nominal voltage.
  • 275 V AC maximum continuous operating voltage (Uc).
  • 1.1 kV voltage protection level (Up).
  • Spark-gap and varistor surge protection technology.
  • Replaceable protection module with QuickSafe end-of-life indication.
  • DIN-rail mounting for straightforward integration into distribution boards.

Combined Lightning and Surge Protection for Electrical Installations

Combined Type 1+2 surge protective devices provide protection against both high-energy lightning currents and transient overvoltages. Type 1 capability enables the SPD to discharge lightning impulse currents characterised by a 10/350 µs waveform, while Type 2 performance handles surge currents characterised by an 8/20 µs waveform, helping protect downstream electrical and electronic equipment.

The ABB OVR T1-T2 QuickSafe range is designed for coordinated protection of low-voltage installations. The OVR T1-T2 12.5-275s P QS combines high discharge capability, replaceable protection technology, a safety reserve and QuickSafe end-of-life indication in a compact DIN-rail device suitable for use in appropriate TT, TN-S and TN-C systems.

Typical Applications

  • Main low-voltage electrical distribution boards.
  • 230 V AC electrical distribution systems.
  • TT, TN-S and TN-C electrical installations.
  • Industrial electrical installations.
  • Commercial buildings and facilities.
  • Installations requiring combined lightning current and surge protection.
  • Machine and automation electrical panels.
  • Protection of sensitive electrical and electronic equipment.

Technical Specifications

Tick the specs you need, then view products that match.

Remote Signal No
Device Type Surge protection device
SPD Type Type 1+2
Impulse Current Iimp (kA) 12.5 kA
Series OVR T1-T2 QuickSafe
ABB order code 2CTB815710R1200
Product group Surge Protection Devices
Product type Combined Type 1+2 surge protective device
Test class Type 1 + Type 2
Variant L1
Number of modules 1
Number of protected lines 1
Distribution systems TT (L-N), TN-S, TN-C
Nominal voltage (Un) 230 V AC
Maximum continuous operating voltage (Uc) 275 V AC
Impulse current Iimp (10/350 µs) 12.5 kA
Nominal discharge current In (8/20 µs) 30 kA
Maximum discharge current Imax (8/20 µs) 80 kA
Voltage protection level (Up) 1.1 kV
Technology Spark gap / varistor
Replaceable module Yes
Safety reserve Yes
QuickSafe end-of-life indicator Yes
Auxiliary contact No
Maximum backup fuse 160 A
Maximum backup circuit breaker 125 A
Solid Cu conductor capacity up to 50 mm²
Flexible Cu conductor capacity up to 35 mm²
Tightening torque 3.5 Nm
Ambient operating temperature -40 to +80 °C
Storage temperature -40 to +80 °C
Protection rating IP20
Standard EN 61643-11
Mounting type DIN rail
Dimensions (H × W × D) approx. 85 × 17.8 × 69.4 mm
Weight approx. 0.15 kg

Frequently Asked Questions

What is the ABB OVR T1-T2 12.5-275s P QS used for?

This device provides combined Type 1+2 lightning current and surge protection for low-voltage electrical installations, helping protect downstream equipment against lightning effects and transient overvoltages.

What is the impulse current rating of the OVR T1-T2 12.5-275s P QS?

The device has an impulse current Iimp of 12.5 kA using a 10/350 µs waveform and a maximum discharge current Imax of 80 kA using an 8/20 µs waveform.

What is the maximum continuous operating voltage?

The ABB OVR T1-T2 12.5-275s P QS has a maximum continuous operating voltage Uc of 275 V AC and a nominal voltage Un of 230 V AC.

Does the OVR T1-T2 12.5-275s P QS have a replaceable module?

Yes. The device has a replaceable protection module and incorporates ABB QuickSafe end-of-life indication and a safety reserve to support straightforward inspection and maintenance.

What is the ABB order code for the OVR T1-T2 12.5-275s P QS?

The ABB order code is 2CTB815710R1200.

Trusted ABB Lightning and Surge Protection Technology

ABB OVR QuickSafe combined Type 1+2 surge protective devices are designed to protect low-voltage installations against lightning currents and transient overvoltages, providing coordinated protection for electrical and electronic equipment in industrial, commercial and infrastructure applications.