ABB OVR T1-T2 4L 12.5-275s P TS QS 2CTB815710R1100 is a four-pole pluggable Type 1 + Type 2 surge protective device for 230/400 V AC TN-S systems with 12.5 kA impulse current per pole, 80 kA maximum discharge current and remote signalling.
£316.01
The ABB OVR T1-T2 4L 12.5-275s P TS QS is a high-performance combined Type 1 + Type 2 surge protective device (SPD) designed to protect three-phase TN-S low-voltage electrical installations against lightning currents and transient overvoltages. Identified by ABB order code 2CTB815710R1100, this four-pole device forms part of the ABB OVR QuickSafe surge protection range and combines lightning-current discharge and secondary surge protection in one compact assembly.
Designed for 230/400 V AC TN-S distribution systems, the OVR T1-T2 4L 12.5-275s P TS QS provides an impulse current capability of 12.5 kA per pole using a 10/350 µs waveform and 50 kA total impulse current. It also provides a 20 kA nominal discharge current and 80 kA maximum discharge current, making it suitable for installations requiring protection against both lightning currents and switching or induced transient surges.
The device incorporates ABB QuickSafe technology, a Safety Reserve function, visual status indication and pluggable protection cartridges for straightforward maintenance. The TS version includes auxiliary signalling contacts for remote condition monitoring, while its four-module DIN-rail format integrates readily into main distribution boards and ABB System pro M compact installations.
Combined Type 1 + Type 2 SPDs are designed to handle both high-energy lightning currents and transient overvoltages within a coordinated protection device. The ABB OVR T1-T2 4L 12.5-275s P TS QS is tested with the 10/350 µs lightning-current waveform associated with Type 1 protection as well as the 8/20 µs discharge-current waveform used for Type 2 surge protection.
Its four-pole architecture is designed for TN-S installations, while the pluggable QuickSafe construction simplifies maintenance of the surge-protection system. Visual status indication provides local condition information, and the TS auxiliary contacts allow the SPD status to be monitored remotely by building-management, control or supervisory systems.
Tick the specs you need, then view products that match.
| Remote Signal | Yes | |
|---|---|---|
| Device Type | Surge protection device | |
| SPD Type | Type 1+2 | |
| Poles | 4-pole | |
| Earthing System | TN-S | |
| Impulse Current Iimp (kA) | 12.5 kA | |
| Series | OVR QuickSafe | |
| ABB order code | 2CTB815710R1100 | |
| EAN | 3660308524942 | |
| Product group | Surge Protection Devices | |
| Product type | Combined Type 1 + Type 2 surge protective device | |
| SPD classification | Type 1 + Type 2 / Class I + II | |
| Number of poles | 4 | |
| Number of protected poles | 4 | |
| Low-voltage distribution system | TN-S | |
| Nominal AC system voltage | 230 / 400 V | |
| Maximum continuous operating voltage (L-PE) | 275 V AC | |
| Maximum continuous operating voltage (L-L) | 440 V AC | |
| Maximum continuous operating voltage (L-N) | 440 V AC | |
| Maximum continuous operating voltage (N-PE) | 275 V AC | |
| Impulse current (Iimp, 10/350 µs) | 12.5 kA | |
| Total impulse current (10/350 µs) | 50 kA | |
| Nominal discharge current (In, 8/20 µs) | 20 kA | |
| Maximum discharge current (Imax, 8/20 µs) | 80 kA | |
| Total discharge current | 320 kA | |
| Voltage protection level (Up L-N) | 2.8 kV | |
| Voltage protection level (Up L-PE) | 1.4 kV | |
| Voltage protection level (Up N-PE) | 1.4 kV | |
| Short-circuit withstand | 100 kA | |
| Status indicator | Yes | |
| Preventive-maintenance function | Yes | |
| Remote signalling | Yes | |
| Auxiliary contacts | 1 NO + 1 NC | |
| Construction | Plug-in / pluggable | |
| Mounting | DIN rail | |
| Protection rating | IP20 | |
| Width in modular spacings | 4 modules | |
| Dimensions (H × W × D) | 95.8 × 71.2 × 76.7 mm | |
| Weight | 0.6 kg | |
| Maximum operating altitude | 5,000 m | |
| Power loss | 63 mW | |
| Standards | IEC 61643-11 / EN 61643-11 |
It is a combined Type 1 + Type 2 surge protective device designed to protect three-phase TN-S low-voltage systems against lightning currents and transient overvoltages.
The device has an impulse current rating of 12.5 kA per pole using a 10/350 µs waveform and a total impulse current capability of 50 kA.
The OVR T1-T2 4L 12.5-275s P TS QS has a maximum discharge current Imax of 80 kA using an 8/20 µs waveform and a nominal discharge current of 20 kA.
Yes. The TS version provides one normally open and one normally closed auxiliary contact for remote monitoring of the surge protective device's operating status.
It is typically installed on a DIN rail in the main distribution board of a TN-S electrical installation, particularly where combined lightning-current and transient-overvoltage protection is required.
ABB OVR Type 1 + Type 2 surge protective devices combine high lightning-current handling, transient surge protection, QuickSafe technology, pluggable maintenance and remote status signalling for dependable protection of modern low-voltage electrical installations.