2CTB815708R4100 ABB OVR T2 80-440s P QS Type 2 Surge Protective Device

2CTB815708R4100 ABB OVR T2 80-440s P QS Type 2 Surge Protective Device

ABB OVR T2 80-440s P QS is a single-pole Type 2 pluggable surge protective device with 440 V AC maximum continuous operating voltage and 80 kA maximum discharge current for low-voltage electrical installations.

SKU: 2CTB815708R4100MPN: 2CTB815708R4100
Price
List Price £136.22 ex VAT
Your Price (ex VAT) Save 25%
£102.17 25% OFF
You save £34.06 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £102.17
Trade pricing is personalised to your account

Manufacturer Lead Time

£102.17

Why Choose the ABB OVR T2 80-440s P QS Surge Protective Device?

The ABB OVR T2 80-440s P QS, order code 2CTB815708R4100, is a high-performance Type 2 surge protective device (SPD) designed to protect low-voltage electrical installations and sensitive equipment against transient overvoltages caused by indirect lightning effects and switching events. As part of the ABB OVR QuickSafe surge protection range, this single-pole device combines high surge-current capability with a compact, pluggable DIN-rail design for dependable protection in electrical distribution systems.

The OVR T2 80-440s P QS uses varistor-based surge protection and incorporates an integrated thermal disconnector, end-of-life indication and ABB's QuickSafe safety reserve technology. Its replaceable protection module simplifies servicing, while the mechanical status indicator provides straightforward visual confirmation of the device's operating condition.

With a maximum continuous operating voltage (Uc) of 440 V AC, nominal discharge current (In) of 20 kA and maximum discharge current (Imax) of 80 kA, this Type 2 SPD provides substantial protection against 8/20 µs surge currents. Its 1.8 kV voltage protection level (Up) helps limit transient voltages reaching downstream equipment in 400 V AC electrical systems.

Key Advantages

  • High-performance Type 2 surge protection for low-voltage electrical installations.
  • 80 kA maximum discharge current (Imax) for robust protection against transient surge events.
  • 20 kA nominal discharge current (In) with an 8/20 µs waveform.
  • 440 V AC maximum continuous operating voltage (Uc).
  • Low 1.8 kV voltage protection level (Up) helps protect downstream equipment.
  • QuickSafe technology with integrated thermal disconnection and safety reserve.
  • Plug-in protection module enables straightforward replacement and maintenance.
  • Mechanical end-of-life indicator provides convenient local status checking.
  • Compact single-module design for efficient DIN-rail installation.

Key Features

  • ABB OVR T2 QuickSafe surge protective device series.
  • Type 2 / Class II surge protection.
  • Single-pole, one protected-line configuration.
  • Maximum discharge current (Imax): 80 kA.
  • Nominal discharge current (In): 20 kA.
  • Impulse current (Iimp): 6.25 kA.
  • Maximum continuous operating voltage (Uc): 440 V AC.
  • Voltage protection level (Up): 1.8 kV.
  • Suitable for nominal 400 V AC networks.
  • Integrated thermal disconnector and end-of-life indicator.
  • Pluggable, replaceable protection module.
  • DIN-rail mounting and System pro M compact compatibility.
  • IP20 degree of protection.
  • Designed and tested as a Type 2 SPD according to IEC 61643-11.

Reliable Surge Protection for Electrical Distribution Systems

Type 2 surge protective devices are designed to discharge transient currents generated by indirect lightning strikes and switching operations before damaging overvoltages can reach sensitive downstream equipment. The ABB OVR T2 80-440s P QS safely handles surge currents with the characteristic 8/20 µs waveform while limiting the residual voltage presented to the protected installation.

The ABB OVR QuickSafe design combines high surge-current capability with practical maintenance features. Its pluggable module can be replaced without changing the complete base assembly, while the integrated thermal disconnector, safety reserve and mechanical end-of-life indication support dependable operation and straightforward maintenance in distribution boards.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Sub-distribution boards and final electrical circuits.
  • Industrial control panels and automation installations.
  • Commercial and industrial buildings.
  • Machinery and production equipment power distribution.
  • 400 V AC electrical networks requiring Type 2 surge protection.
  • Protection against indirect lightning-induced and switching overvoltages.

Technical Specifications

Tick the specs you need, then view products that match.

Remote Signal No
Device Type Surge protection device
SPD Type Type 2
Poles 1-pole
Impulse Current Iimp (kA) 6.25 kA
Series OVR T2 QuickSafe
ABB order code 2CTB815708R4100
Product type Surge protective device (SPD)
SPD classification Type 2 / Class II
Number of protected lines 1
Protection mode L-N / L-PE
Nominal voltage (Un) 400 V AC
Maximum continuous operating voltage (Uc) 440 V AC
Maximum continuous operating voltage DC 560 V DC
Nominal discharge current (In, 8/20 µs) 20 kA
Maximum discharge current (Imax, 8/20 µs) 80 kA
Impulse current (Iimp, 10/350 µs) 6.25 kA
Voltage protection level (Up) 1.8 kV
AC frequency 47–63 Hz
Short-circuit current rating 100 kA
Integrated thermal disconnector Yes
End-of-life indicator Yes
Safety reserve Yes
Response time <25 ns
Protection rating IP20
Mounting type DIN rail
Solid conductor range 2.5–35 mm²
Stranded conductor range 2.5–25 mm²
Dimensions (H × W × D) 88 × 17.8 × 69.4 mm
Weight approx. 150 g
Maximum installation altitude 2000 m
Fire resistance UL 94 V-0
Standard IEC 61643-11
EAN 3660308525604

Frequently Asked Questions

What is the ABB OVR T2 80-440s P QS used for?

It is a Type 2 surge protective device designed to protect low-voltage electrical installations and sensitive equipment against transient overvoltages caused by indirect lightning effects and electrical switching events.

What is the maximum discharge current of the 2CTB815708R4100?

The ABB OVR T2 80-440s P QS has a maximum discharge current (Imax) of 80 kA for an 8/20 µs surge-current waveform.

What is the maximum continuous operating voltage?

The device has a maximum continuous operating voltage (Uc) of 440 V AC and is designed for use on appropriate 400 V AC electrical networks.

Is the ABB OVR T2 80-440s P QS replaceable?

Yes. The device has a pluggable protection module, allowing the protection cartridge to be replaced while retaining the installed base.

Where is the ABB OVR T2 80-440s P QS installed?

It is designed for DIN-rail installation in main and sub-distribution boards and can be used to provide Type 2 surge protection for low-voltage electrical equipment and circuits.

Trusted Surge Protection from ABB

ABB OVR QuickSafe surge protective devices combine high surge-current capability, pluggable construction and integrated condition indication to provide dependable protection for modern low-voltage electrical distribution systems.