2CTB815708R0600 ABB OVR T2 3L 80-275s P TS QS Surge Protective Device

2CTB815708R0600 ABB OVR T2 3L 80-275s P TS QS Surge Protective Device

ABB OVR T2 3L 80-275s P TS QS is a three-pole pluggable Type 2 surge protective device for 230/400 V AC TN-C systems, with Safety Reserve technology, 20 kA nominal discharge current, 80 kA maximum discharge current, 275 V AC maximum continuous operating voltage and remote status signalling.

SKU: 2CTB815708R0600MPN: 2CTB815708R0600
Price
List Price £518.39 ex VAT
Your Price (ex VAT) Save 25%
£388.79 25% OFF
You save £129.60 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £388.79
Trade pricing is personalised to your account

Manufacturer Lead Time

£388.79

Why Choose the ABB OVR T2 3L 80-275s P TS QS Surge Protective Device?

The ABB OVR T2 3L 80-275s P TS QS, order code 2CTB815708R0600, is a high-capacity Type 2 surge protective device (SPD) designed for three-phase 230/400 V AC TN-C electrical systems. Installed in main distribution boards or sub-distribution boards, it protects electrical installations and connected equipment against transient overvoltages caused by indirect lightning effects and switching events.

The OVR T2 3L 80-275s P TS QS provides three protected L-PEN paths with a maximum continuous operating voltage of 275 V AC. It has a nominal discharge current In of 20 kA and a high maximum discharge current Imax of 80 kA using the 8/20 µs waveform, together with an impulse-current capability Iimp of 6.25 kA using the 10/350 µs waveform.

ABB's patented Safety Reserve system provides a preventive-maintenance function that helps extend protection availability, while QuickSafe technology supports dependable end-of-life disconnection. Pluggable construction, visual status indication and TS remote signalling with one normally open and one normally closed auxiliary contact make this SPD particularly suitable for demanding commercial and industrial installations where local and remote condition monitoring are required.

Key Advantages

  • High-capacity Type 2 / Class II surge protection for three-phase TN-C systems.
  • Exceptional 80 kA maximum discharge current using the 8/20 µs waveform.
  • 20 kA nominal discharge current for effective transient surge suppression.
  • 6.25 kA impulse-current capability using the 10/350 µs waveform.
  • Low 1.4 kV voltage protection level helps safeguard downstream equipment.
  • Safety Reserve system supports preventive maintenance and increased protection availability.
  • Patented QuickSafe technology provides improved operational safety.
  • TS remote signalling enables connection to monitoring and alarm systems.
  • Pluggable construction simplifies servicing and replacement.
  • 100 kA short-circuit withstand capability supports demanding distribution applications.

Key Features

  • ABB OVR T2 QuickSafe series.
  • Type 2 / Class II surge protective device.
  • Three protected lines.
  • Designed for TN-C low-voltage distribution systems.
  • L-PEN protection mode.
  • 230 V AC rated voltage.
  • 230/400 V AC nominal system voltage.
  • 275 V AC maximum continuous operating voltage.
  • 20 kA nominal discharge current In.
  • 80 kA maximum discharge current Imax.
  • 6.25 kA impulse current Iimp.
  • 1.4 kV voltage protection level Up.
  • Safety Reserve preventive-maintenance function.
  • Pluggable construction with visual status indication.
  • 1 NO + 1 NC auxiliary contacts for remote signalling.

High-Capacity Type 2 Protection with Safety Reserve Technology

Type 2 SPDs are designed to discharge surge currents associated with indirect lightning effects and switching operations before damaging transient voltages reach connected equipment. With an 80 kA maximum 8/20 µs discharge-current rating, the ABB OVR T2 3L 80-275s P TS QS provides particularly high surge-current capability while maintaining a low 1.4 kV protection level for downstream equipment.

ABB's patented Safety Reserve system is designed to extend protection availability and support planned preventive maintenance, helping reduce the risk of downtime. The pluggable architecture simplifies replacement, while local status indication and TS auxiliary contacts allow maintenance personnel to monitor the SPD both at the switchboard and through suitable remote monitoring or alarm equipment.

Typical Applications

  • Three-phase 230/400 V AC TN-C electrical systems.
  • Main low-voltage distribution switchboards.
  • Industrial sub-distribution boards.
  • Commercial building electrical panels.
  • Manufacturing and process-control installations.
  • Protection of industrial automation and electronic equipment.
  • Installations exposed to significant transient surge currents.
  • Applications requiring preventive SPD maintenance indication.
  • Systems requiring remote surge-protection status monitoring.

Technical Specifications

Tick the specs you need, then view products that match.

Remote Signal Yes
Device Type Surge protection device
SPD Type Type 2
Poles 3-pole
Earthing System TN-C
Impulse Current Iimp (kA) 6.25 kA
Series OVR T2 QuickSafe
ABB order code 2CTB815708R0600
EAN / GTIN 3660308525437
Product group Surge Protection Devices
Product type Type 2 surge protective device
SPD classification Type 2 / Class II
Standards IEC 61643-11 / EN 61643-11
Low-voltage distribution system TN-C
Protection mode L-PEN
Number of poles 3
Number of protected lines 3
Rated voltage 230 V AC
Nominal system voltage 230 / 400 V AC
Frequency 45–65 Hz
Maximum continuous operating voltage Uc 275 V AC
Impulse current Iimp (10/350 µs) 6.25 kA
Nominal discharge current In (8/20 µs) 20 kA
Maximum discharge current Imax (8/20 µs) 80 kA
Voltage protection level Up 1.4 kV
Short-circuit withstand capability 100 kA
Rated service short-circuit breaking capacity Ics 100 kA
Maximum backup fuse 160 A
Maximum backup circuit breaker 125 A
Preventive maintenance function Yes
Safety Reserve Yes
QuickSafe technology Yes
Status indicator Yes
Remote signalling Yes
Normally open auxiliary contacts 1
Normally closed auxiliary contacts 1
Construction Pluggable
Replacement cartridge OVR T2 80-275s C QS
Replacement cartridge order code 2CTB815708R2600
Degree of protection IP20
Operating temperature -40 to +80 °C
Maximum operating altitude 5000 m
Power loss 49 mW
Mounting type DIN rail
Width 53.4 mm
Height 95.8 mm
Depth 76.7 mm
Weight 0.45 kg

Frequently Asked Questions

What is the ABB OVR T2 3L 80-275s P TS QS used for?

It is a Type 2 surge protective device designed for three-phase 230/400 V AC TN-C systems, protecting electrical installations and connected equipment against transient overvoltages caused by indirect lightning effects and electrical switching events.

What are the discharge-current ratings of the OVR T2 3L 80-275s P TS QS?

The device has a nominal discharge current In of 20 kA and a maximum discharge current Imax of 80 kA using the 8/20 µs waveform, together with a 6.25 kA impulse-current capability using the 10/350 µs waveform.

What does the “s” mean in OVR T2 3L 80-275s?

The “s” identifies the Safety Reserve version. ABB's patented Safety Reserve system provides a preventive-maintenance function designed to extend protection availability and help maintenance personnel plan cartridge replacement.

What does TS mean on the OVR T2 3L 80-275s P TS QS?

The TS version includes remote signalling through one normally open and one normally closed auxiliary contact, allowing SPD condition information to be integrated with suitable monitoring or alarm systems.

Can the protection cartridges be replaced?

Yes. The OVR T2 3L 80-275s P TS QS has a pluggable construction and uses the ABB OVR T2 80-275s C QS replacement cartridge, order code 2CTB815708R2600.

Trusted ABB Surge Protection Technology

ABB OVR Type 2 surge protective devices combine high surge-current capability, patented QuickSafe technology and pluggable construction, with the OVR T2 3L 80-275s P TS QS delivering 80 kA maximum discharge capability, Safety Reserve preventive maintenance and remote status signalling for demanding three-phase TN-C electrical installations.