Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB OVR T2 3N 40-440s P TS QS is a pluggable 3+1 Type 2 surge protective device for 400/690 V AC TN-S and TT systems, with Safety Reserve technology, 20 kA nominal discharge current, 40 kA maximum discharge current, 440 V AC maximum continuous operating voltage and remote status signalling.
£488.69
The ABB OVR T2 3N 40-440s P TS QS, order code 2CTB815704R3700, is a high-performance Type 2 surge protective device (SPD) designed for three-phase plus neutral 400/690 V AC TN-S and TT electrical systems. Installed in main or sub-distribution switchboards, it protects low-voltage installations and sensitive equipment against transient overvoltages caused by indirect lightning effects and electrical switching events.
The OVR T2 3N 40-440s P TS QS uses a 3+1 protection configuration and has a maximum continuous operating voltage Uc of 440 V AC. It provides a nominal discharge current In of 20 kA and a maximum discharge current Imax of 40 kA using the 8/20 µs waveform, with a total maximum discharge-current capability of 160 kA.
ABB's Safety Reserve technology provides an additional protection stage to maintain basic surge protection when the primary varistor reaches end of life, while QuickSafe technology supports reliable thermal disconnection. Pluggable cartridges, visual condition indication and TS remote signalling with one normally open and one normally closed contact make the device particularly suitable for installations where straightforward maintenance and remote SPD monitoring are required.
Type 2 SPDs are designed to discharge transient currents generated by indirect lightning effects and electrical switching before damaging overvoltages reach downstream equipment. The ABB OVR T2 3N 40-440s P TS QS combines 20 kA nominal and 40 kA maximum discharge-current ratings with a coordinated 3+1 topology for three-phase plus neutral TN-S and TT systems.
The Safety Reserve function increases protection availability by retaining a basic level of surge protection when the primary varistor protection stage reaches end of life. Together with visual indication, individually replaceable cartridges and TS auxiliary contacts, this enables maintenance personnel to identify deterioration, remotely monitor SPD status and schedule replacement without unnecessarily changing the complete surge protection assembly.
Tick the specs you need, then view products that match.
| Remote Signal | Yes | |
|---|---|---|
| SPD Type | Type 2 | |
| Poles | 3-pole + N | |
| Earthing System | TN-S, TT | |
| Device Type | Surge protection device | |
| Impulse Current Iimp (kA) | 2 kA | |
| Series | OVR T2 QuickSafe | |
| ABB order code | 2CTB815704R3700 | |
| EAN / GTIN | 3660308525376 | |
| Product group | Surge Protection Devices | |
| Product type | Type 2 surge protective device | |
| SPD classification | Type 2 / Class II | |
| Standards | IEC 61643-11 / EN 61643-11 | |
| Low-voltage distribution systems | TN-S / TT | |
| Configuration | 3+1 | |
| Number of poles | 4 | |
| Nominal system voltage | 400 / 690 V AC | |
| Frequency | 45–65 Hz | |
| Maximum continuous operating voltage Uc | 440 V AC | |
| Impulse current Iimp (10/350 µs) | 2 kA | |
| Nominal discharge current In (8/20 µs) | 20 kA | |
| Maximum discharge current Imax (8/20 µs) | 40 kA | |
| Total maximum discharge current | 160 kA | |
| Voltage protection level Up, L-N | 1.8 kV | |
| Voltage protection level Up, N-PE | 1.4 kV | |
| Voltage protection level Up, L-PE | 2.1 kV | |
| Temporary overvoltage withstand | 581 / 1200 V | |
| Response time | <26 ns | |
| Short-circuit withstand capability Isccr | 100 kA | |
| Maximum backup fuse | 160 A | |
| Maximum backup circuit breaker | 125 A | |
| Safety Reserve | Yes | |
| QuickSafe technology | Yes | |
| Status indication | Yes | |
| Remote signalling | Yes | |
| Normally open auxiliary contacts | 1 | |
| Normally closed auxiliary contacts | 1 | |
| Minimum auxiliary contact load | 12 V DC / 10 mA | |
| Maximum auxiliary contact load | 250 V AC / 1 A | |
| Solid conductor connection | 2.5–25 mm² | |
| Stranded conductor connection | 2.5–35 mm² | |
| Wire stripping length | 12.5 mm | |
| Construction | Pluggable | |
| Phase replacement cartridge | OVR T2 40-440s C QS | |
| Phase replacement cartridge order code | 2CTB815704R5500 | |
| Neutral replacement cartridge | OVR T2 N 80-440s C QS | |
| Neutral replacement cartridge order code | 2CTB815708R5700 | |
| Degree of protection | IP20 | |
| Flammability rating | V-0 | |
| Operating temperature | -40 to +80 °C | |
| Mounting type | 35 mm DIN rail | |
| Module width | 4 modules | |
| Dimensions (H × W × D) | 95.8 × 71.2 × 76.7 mm |
It is a Type 2 surge protective device for three-phase plus neutral 400/690 V AC TN-S and TT systems, designed to protect electrical installations and sensitive equipment against transient overvoltages caused by indirect lightning effects and switching events.
The device has a nominal discharge current In of 20 kA and a maximum discharge current Imax of 40 kA using the 8/20 µs waveform, with a total maximum discharge-current capability of 160 kA across the complete assembly.
The “s” identifies the Safety Reserve version. ABB's reserve-varistor design maintains basic surge protection when the primary protection stage reaches end of life, helping keep the installation protected until the affected cartridge is replaced.
The TS version includes remote signalling through one normally open and one normally closed auxiliary contact, allowing SPD status to be integrated into suitable monitoring, alarm or building-management systems.
Yes. The device uses pluggable cartridges. The phase replacement is the ABB OVR T2 40-440s C QS, order code 2CTB815704R5500, while the neutral replacement is the ABB OVR T2 N 80-440s C QS, order code 2CTB815708R5700.
ABB OVR Type 2 surge protective devices combine high surge-current capability, QuickSafe technology and pluggable construction, with the OVR T2 3N 40-440s P TS QS adding Safety Reserve functionality and remote status signalling for dependable protection of three-phase plus neutral commercial and industrial electrical systems.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.