2CTB815704R2900 ABB OVR T2 40-440s P TS QS Surge Protective Device

2CTB815704R2900 ABB OVR T2 40-440s P TS QS Surge Protective Device

ABB OVR T2 40-440s P TS QS is a single-pole pluggable Type 2 surge protective device with Safety Reserve technology, 20 kA nominal discharge current, 40 kA maximum discharge current, 440 V AC maximum continuous operating voltage and remote status signalling.

SKU: 2CTB815704R2900MPN: 2CTB815704R2900
Price
List Price £153.98 ex VAT
Your Price (ex VAT) Save 25%
£115.49 25% OFF
You save £38.50 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £115.49
Trade pricing is personalised to your account

Manufacturer Lead Time

£115.49

Why Choose the ABB OVR T2 40-440s P TS QS Surge Protective Device?

The ABB OVR T2 40-440s P TS QS, order code 2CTB815704R2900, is a compact Type 2 surge protective device (SPD) designed to protect low-voltage electrical installations against transient overvoltages caused by indirect lightning effects and switching events. Its single-pole design is suitable for coordinated protection in TT, TN-C, TN-S and IT distribution systems.

Designed for 400 V AC applications and 400/690 V AC systems, the OVR T2 40-440s P TS QS has a maximum continuous operating voltage Uc of 440 V AC. It provides a nominal discharge current In of 20 kA and a maximum discharge current Imax of 40 kA using the 8/20 µs waveform, together with a voltage protection level Up of 1.8 kV.

The device combines ABB QuickSafe technology with a Safety Reserve preventive-maintenance function, pluggable construction and visual status indication. The TS remote-signalling contacts provide one normally open and one normally closed auxiliary contact for remote condition monitoring, while the compact 17.8 mm DIN-rail width makes the SPD easy to integrate into space-conscious switchboards.

Key Advantages

  • Reliable Type 2 / Class II surge protection against indirect lightning and switching transients.
  • 40 kA maximum discharge current using the 8/20 µs waveform.
  • 20 kA nominal discharge current for effective transient surge suppression.
  • 440 V AC maximum continuous operating voltage for higher-voltage AC networks.
  • 1.8 kV voltage protection level helps limit transient stress on downstream equipment.
  • Safety Reserve functionality provides preventive-maintenance indication and increased protection availability.
  • ABB QuickSafe technology provides rapid and dependable end-of-life disconnection.
  • TS remote signalling enables integration with monitoring and alarm systems.
  • Pluggable cartridge construction simplifies servicing and replacement.
  • 100 kA short-circuit withstand capability supports demanding installations.

Key Features

  • ABB OVR T2 QuickSafe series.
  • Type 2 / Class II surge protective device.
  • Single-pole, single protected-line configuration.
  • Suitable for TT, TN-C, TN-S and IT systems.
  • 400 V AC rated voltage.
  • 400/690 V AC nominal system voltage.
  • 440 V AC maximum continuous operating voltage Uc.
  • 2 kA impulse current Iimp using a 10/350 µs waveform.
  • 20 kA nominal discharge current In.
  • 40 kA maximum discharge current Imax.
  • 1.8 kV voltage protection level Up.
  • Safety Reserve preventive-maintenance function.
  • Pluggable protection cartridge with visual status indication.
  • 1 NO + 1 NC auxiliary contacts for remote signalling.

Safety Reserve Type 2 Protection for Higher-Voltage AC Networks

Type 2 SPDs are designed to discharge transient currents associated with indirect lightning events and switching operations before damaging overvoltages reach connected equipment. The ABB OVR T2 40-440s P TS QS combines a 20 kA nominal discharge current, 40 kA maximum discharge current and 1.8 kV protection level with a 440 V AC continuous operating rating for higher-voltage distribution applications.

The Safety Reserve feature supports preventive maintenance and increased surge-protection availability, while the pluggable cartridge allows the protection module to be replaced without changing the complete base assembly. Visual indication provides local status information, and the TS auxiliary contacts allow the SPD condition to be incorporated into remote monitoring, alarm or building-management systems.

Typical Applications

  • 400/690 V AC low-voltage distribution systems.
  • Industrial main and sub-distribution boards.
  • Commercial building switchboards.
  • TN-C and TN-S electrical networks.
  • TT distribution systems using the appropriate protection arrangement.
  • IT electrical distribution systems.
  • Industrial automation and control panels.
  • Protection of sensitive electrical and electronic equipment.
  • Installations requiring preventive SPD maintenance indication.
  • Systems requiring remote surge-protection status monitoring.

Technical Specifications

Tick the specs you need, then view products that match.

Remote Signal Yes
SPD Type Type 2
Poles 1-pole
Device Type Surge protection device
Impulse Current Iimp (kA) 2 kA
Series OVR T2 QuickSafe
ABB order code 2CTB815704R2900
EAN / GTIN 3660308525369
Product group Surge Protection Devices
Product type Type 2 surge protective device
SPD classification Type 2 / Class II
Standards IEC 61643-11 / EN 61643-11
Protection technology Varistor
Low-voltage distribution systems TT / TN-C / TN-S / IT
Number of poles 1
Number of protected poles 1
Rated voltage 400 V AC
Nominal system voltage 400 / 690 V AC
Voltage rating DC 560 V DC
Frequency 45–65 Hz
Maximum continuous operating voltage Uc 440 V AC
Impulse current Iimp (10/350 µs) 2 kA
Nominal discharge current In (8/20 µs) 20 kA
Maximum discharge current Imax (8/20 µs) 40 kA
Voltage protection level Up 1.8 kV
Short-circuit withstand capability 100 kA
Rated service short-circuit breaking capacity Ics 100 kA
Maximum backup fuse or circuit breaker 125 A
Response time ≤25 ns
Preventive maintenance function Yes
Safety Reserve Yes
QuickSafe technology Yes
Status indicator Yes
Remote signalling Yes
Normally open auxiliary contacts 1
Normally closed auxiliary contacts 1
Minimum auxiliary contact load 12 V DC / 10 mA
Maximum auxiliary contact load 250 V AC / 1 A
Construction Pluggable
Replacement cartridge OVR T2 40-440s C QS
Replacement cartridge order code 2CTB815704R5500
Degree of protection IP20
Flammability rating UL 94 V-0
Operating temperature -40 to +80 °C
Maximum operating altitude 5000 m
Mounting type DIN rail
Module width 1 module
Dimensions (H × W × D) 95.8 × 17.8 × 76.7 mm
Weight 0.15 kg

Frequently Asked Questions

What is the ABB OVR T2 40-440s P TS QS used for?

It is a Type 2 surge protective device designed to protect low-voltage electrical installations against transient overvoltages caused by indirect lightning effects and electrical switching events, particularly in higher-voltage AC distribution systems.

What are the discharge-current ratings of the OVR T2 40-440s P TS QS?

The device has a nominal discharge current In of 20 kA and a maximum discharge current Imax of 40 kA using the 8/20 µs waveform, together with a 2 kA impulse-current capability using the 10/350 µs waveform.

What does the “s” mean in OVR T2 40-440s?

The “s” identifies the Safety Reserve version, which incorporates a preventive-maintenance function designed to increase protection availability and provide an indication when SPD maintenance or cartridge replacement is required.

What does TS mean on the OVR T2 40-440s P TS QS?

The TS version includes remote signalling through one normally open and one normally closed auxiliary contact, allowing the SPD condition to be integrated with suitable monitoring, alarm or building-management systems.

Can the protection cartridge be replaced?

Yes. The OVR T2 40-440s P TS QS has a pluggable protection cartridge. The compatible replacement is the ABB OVR T2 40-440s C QS, order code 2CTB815704R5500.

Trusted ABB Surge Protection Technology

ABB OVR Type 2 surge protective devices combine high surge-current capability, QuickSafe technology and pluggable construction, with the OVR T2 40-440s P TS QS adding Safety Reserve functionality and remote status signalling for dependable surge protection in higher-voltage commercial and industrial electrical installations.