2CTB815704R1400 ABB OVR T2 1N 40-275s P QS Surge Protective Device

2CTB815704R1400 ABB OVR T2 1N 40-275s P QS Surge Protective Device

ABB OVR T2 1N 40-275s P QS is a pluggable 1+1 Type 2 surge protective device for 230 V AC TN-S and TT systems, with Safety Reserve technology, 20 kA nominal discharge current, 40 kA maximum discharge current, 275 V AC maximum continuous operating voltage and a 1.4 kV protection level.

SKU: 2CTB815704R1400MPN: 2CTB815704R1400
Price
List Price £232.48 ex VAT
Your Price (ex VAT) Save 25%
£174.36 25% OFF
You save £58.12 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £174.36
Trade pricing is personalised to your account

Manufacturer Lead Time

£174.36

Why Choose the ABB OVR T2 1N 40-275s P QS Surge Protective Device?

The ABB OVR T2 1N 40-275s P QS, order code 2CTB815704R1400, is a Type 2 surge protective device (SPD) designed for single-phase plus neutral 230 V AC TN-S and TT electrical systems. It protects low-voltage installations and sensitive electrical equipment against transient overvoltages caused by indirect lightning effects and switching events.

The OVR T2 1N 40-275s P QS provides a nominal discharge current In of 20 kA and a maximum discharge current Imax of 40 kA using the 8/20 µs waveform. It has a maximum continuous operating voltage Uc of 275 V AC, an impulse-current capability Iimp of 2 kA using the 10/350 µs waveform and a voltage protection level Up of 1.4 kV.

Its 1+1 configuration combines phase and neutral protection in a compact two-module assembly. ABB's Safety Reserve function provides preventive-maintenance capability by retaining basic protection through a reserve varistor when the primary protection stage reaches end of life, while QuickSafe technology, pluggable cartridges and visual status indication simplify inspection and servicing.

Key Advantages

  • Reliable Type 2 / Class II surge protection for single-phase plus neutral installations.
  • Designed for 230 V AC TN-S and TT systems.
  • 40 kA maximum discharge current using the 8/20 µs waveform.
  • 20 kA nominal discharge current for effective transient surge suppression.
  • 1.4 kV voltage protection level helps limit transient stress on downstream equipment.
  • Safety Reserve technology provides continued basic protection after the primary protection stage reaches end of life.
  • ABB QuickSafe technology supports safe and reliable end-of-life disconnection.
  • Pluggable phase and neutral cartridges simplify maintenance.
  • 100 kA short-circuit withstand capability supports demanding installations.
  • Compact 35.6 mm two-module width conserves distribution-board space.

Key Features

  • ABB OVR T2 QuickSafe series.
  • Type 2 / Class II surge protective device.
  • 1+1 protected-line configuration.
  • Suitable for TN-S and TT low-voltage networks.
  • 230 V AC nominal voltage.
  • 230/400 V AC nominal system voltage.
  • 275 V AC maximum continuous operating voltage Uc.
  • 2 kA impulse current Iimp using a 10/350 µs waveform.
  • 20 kA nominal discharge current In.
  • 40 kA maximum discharge current Imax.
  • 1.4 kV voltage protection level Up.
  • Safety Reserve preventive-maintenance function.
  • Pluggable protection cartridges with visual status indication.
  • IP20 degree of protection.

Safety Reserve Surge Protection for Single-Phase TN-S and TT Systems

Type 2 surge protective devices are designed to discharge transient currents associated with indirect lightning effects and switching operations before damaging overvoltages reach connected equipment. The ABB OVR T2 1N 40-275s P QS combines a 20 kA nominal discharge current, 40 kA maximum discharge current and 1.4 kV protection level in a compact 1+1 configuration for single-phase plus neutral installations.

The Safety Reserve design provides an important preventive-maintenance benefit. When the primary varistor reaches the end of its service life, a smaller reserve varistor maintains basic surge protection until replacement can be carried out. Visual status indication and individually pluggable phase and neutral cartridges make it easier to identify and replace the affected protection element without replacing the complete SPD assembly.

Typical Applications

  • Single-phase 230 V AC TN-S electrical installations.
  • Single-phase 230 V AC TT electrical installations.
  • Residential consumer units and distribution boards.
  • Commercial building distribution panels.
  • Industrial sub-distribution boards.
  • Protection of sensitive electronic equipment.
  • Building automation, control and communication equipment.
  • Installations requiring preventive SPD maintenance indication.
  • Coordinated ABB OVR surge protection systems.

Technical Specifications

Tick the specs you need, then view products that match.

Remote Signal No
Device Type Surge protection device
SPD Type Type 2
Poles 1-pole + N
Earthing System TN-S, TT
Impulse Current Iimp (kA) 2 kA
Series OVR T2 QuickSafe
ABB order code 2CTB815704R1400
EAN / GTIN 3660308525307
Product group Surge Protection Devices
Product type Type 2 surge protective device
SPD classification Type 2 / Class II
Standards IEC 61643-11 / EN 61643-11
Low-voltage distribution systems TN-S / TT
Protected lines 1+1
Number of poles 2
Number of protected poles 2
Nominal voltage Un 230 V AC
Nominal system voltage 230 / 400 V AC
Maximum continuous operating voltage Uc 275 V AC
Impulse current Iimp (10/350 µs) 2 kA
Nominal discharge current In (8/20 µs) 20 kA
Maximum discharge current Imax (8/20 µs) 40 kA
Voltage protection level Up 1.4 kV
Short-circuit withstand capability Isccr 100 kA
Rated service short-circuit breaking capacity Ics 100 kA
Maximum backup circuit breaker 125 A, B or C curve
Preventive maintenance function Yes
Safety Reserve Yes
QuickSafe technology Yes
Status indicator Yes
Remote signalling No
Construction Pluggable
Phase replacement cartridge OVR T2 40-275s C QS
Phase replacement cartridge order code 2CTB815704R2600
Neutral replacement cartridge OVR T2 N 80-275s C QS
Neutral replacement cartridge order code 2CTB815708R2800
Degree of protection IP20
Operating temperature -40 to +80 °C
Maximum operating altitude 5000 m
Power loss 28 mW
Mounting type 35 mm DIN rail
Module width 2 modules
Dimensions (H × W × D) 95.8 × 35.6 × 76.7 mm
Weight approx. 0.30 kg

Frequently Asked Questions

What is the ABB OVR T2 1N 40-275s P QS used for?

It is a Type 2 surge protective device for single-phase plus neutral 230 V AC TN-S and TT systems, protecting electrical installations and sensitive equipment against transient overvoltages caused by indirect lightning effects and switching events.

What are the discharge-current ratings of the OVR T2 1N 40-275s P QS?

The device has a nominal discharge current In of 20 kA and a maximum discharge current Imax of 40 kA using the 8/20 µs waveform, together with a 2 kA impulse-current capability using the 10/350 µs waveform.

What does the “s” mean in OVR T2 1N 40-275s?

The “s” identifies the Safety Reserve version. A reserve varistor maintains basic surge protection after the primary protection stage reaches end of life, allowing the cartridge to be replaced while the installation retains a level of protection.

Does the OVR T2 1N 40-275s P QS have remote signalling?

No. ABB order code 2CTB815704R1400 does not include auxiliary remote-signalling contacts. The OVR T2 1N 40-275s P TS QS version is available where remote SPD status monitoring is required.

Can the phase and neutral protection cartridges be replaced?

Yes. The SPD uses pluggable cartridges. The phase replacement cartridge is the OVR T2 40-275s C QS, order code 2CTB815704R2600, while the neutral replacement cartridge is the OVR T2 N 80-275s C QS, order code 2CTB815708R2800.

Trusted ABB Surge Protection Technology

ABB OVR Type 2 surge protective devices combine high surge-current capability, QuickSafe technology and pluggable construction, with the OVR T2 1N 40-275s P QS adding Safety Reserve functionality for dependable single-phase plus neutral surge protection and planned preventive maintenance.