2CTB813012R2300 ABB OVR T1-T2 N 100-255 C Type 1+2 Surge Protection Cartridge

2CTB813012R2300 ABB OVR T1-T2 N 100-255 C Type 1+2 Surge Protection Cartridge

ABB OVR T1-T2 N 100-255 C is a replaceable Type 1+2 neutral-to-earth surge protection cartridge with 100 kA impulse current, 60 kA maximum discharge current, 25 kA nominal discharge current and 255 V AC maximum continuous operating voltage for compatible TT and TN-S electrical systems.

SKU: 2CTB813012R2300MPN: 2CTB813012R2300
Price
List Price £631.10 ex VAT
Your Price (ex VAT) Save 25%
£473.33 25% OFF
You save £157.78 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £473.33
Trade pricing is personalised to your account

Manufacturer Lead Time

£473.33

Why Choose the ABB OVR T1-T2 N 100-255 C Surge Protection Cartridge?

The ABB OVR T1-T2 N 100-255 C, order code 2CTB813012R2300, is a replaceable Type 1+2 surge protection cartridge designed for neutral-to-earth protection in compatible ABB OVR surge protection assemblies. Intended for low-voltage TT and TN-S electrical systems, it provides high-capacity protection against lightning currents and transient overvoltages.

Designed for systems with nominal AC voltages from 233–400 V AC, the OVR T1-T2 N 100-255 C has a maximum continuous operating voltage (Uc) of 255 V AC between N-PE. It provides a substantial 100 kA impulse current (Iimp) with a 10/350 µs waveform, alongside a 25 kA nominal discharge current (In) and 60 kA maximum discharge current (Imax) with an 8/20 µs waveform.

With a 1.5 kV voltage protection level, 100 kA short-circuit withstand capability and compact replaceable construction, the cartridge provides a straightforward way to restore compatible ABB OVR Type 1+2 surge protection devices after the protection element reaches the end of its service life.

Key Advantages

  • Replaceable Type 1+2 neutral-to-earth surge protection cartridge.
  • High 100 kA impulse current (Iimp) with a 10/350 µs waveform.
  • 60 kA maximum discharge current (Imax) with an 8/20 µs waveform.
  • 25 kA nominal discharge current (In) with an 8/20 µs waveform.
  • 1.5 kV voltage protection level (Up) helps limit transient overvoltages.
  • 255 V AC maximum continuous operating voltage between neutral and protective earth.
  • 100 kA short-circuit withstand capability for demanding low-voltage installations.
  • Replaceable cartridge design enables servicing without replacing the complete compatible SPD assembly.

Key Features

  • ABB OVR T1-T2 surge protection range.
  • Type 1+2 surge protection cartridge.
  • Single-pole neutral-to-earth (N-PE) protection.
  • Suitable for TT and TN-S low-voltage distribution systems.
  • 100 kA impulse current (10/350 µs).
  • 60 kA maximum discharge current (8/20 µs).
  • 25 kA nominal discharge current (8/20 µs).
  • 255 V AC maximum continuous operating voltage.
  • 1.5 kV voltage protection level.
  • 100 kA rated service short-circuit breaking capacity.
  • 100 kA short-circuit withstand.
  • Compact replaceable cartridge construction.
  • Compliant with IEC 61643-11, EN 61643-11 and UL 1449 5th Edition.

High-Capacity Replacement Protection for TT and TN-S Systems

Type 1+2 surge protection combines the ability to handle high-energy lightning-current impulses with protection against transient overvoltages generated by indirect lightning and switching events. Neutral-to-earth protection is particularly important within compatible TT and TN-S surge protection arrangements, providing a controlled discharge path between neutral and protective earth during transient events.

The ABB OVR T1-T2 N 100-255 C provides a 100 kA 10/350 µs impulse-current capability together with 60 kA maximum 8/20 µs discharge current. As a replaceable cartridge, it allows compatible ABB OVR assemblies to be serviced efficiently while retaining the existing SPD base and associated installation wiring.

Typical Applications

  • Replacement cartridge for compatible ABB OVR T1-T2 surge protection assemblies.
  • TT low-voltage electrical distribution systems.
  • TN-S low-voltage electrical distribution systems.
  • Neutral-to-earth protection in coordinated SPD installations.
  • Main electrical distribution boards.
  • Commercial building electrical systems.
  • Industrial low-voltage distribution installations.
  • Protection against lightning currents and transient overvoltages.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Replacement cartridge
Impulse Current Iimp (kA) 100 kA
Series OVR T1-T2
Order code / MPN 2CTB813012R2300
Product group Surge Protection Devices
Product type Replacement surge protection cartridge
SPD classification Type 1+2
Protection mode N-PE
Number of poles 1
Number of protected poles 1
Low-voltage distribution systems TT, TN-S
Nominal AC system voltage 233–400 V AC
Maximum continuous operating voltage (Uc, N-PE) 255 V AC
Impulse current (Iimp, 10/350 µs) 100 kA
Nominal discharge current (In, 8/20 µs) 25 kA
Maximum discharge current (Imax, 8/20 µs) 60 kA
Voltage protection level (Up) 1.5 kV
Temporary overvoltage withstand (N-PE) 1200 V / 200 ms
Rated service short-circuit breaking capacity (Ics) 100 kA
Short-circuit withstand (Icc) 100 kA
Operating temperature -40 to +70 °C
Maximum operating altitude 2000 m
Standards IEC 61643-11, EN 61643-11, UL 1449 5th Edition
Dimensions (H × W × D) 45 × 36 × 61 mm
Weight 0.15 kg
Construction Replaceable cartridge

Frequently Asked Questions

What is the ABB OVR T1-T2 N 100-255 C used for?

The ABB OVR T1-T2 N 100-255 C is a replaceable Type 1+2 neutral-to-earth surge protection cartridge designed for compatible ABB OVR surge protection assemblies used in TT and TN-S low-voltage electrical systems.

What is the impulse current rating of the OVR T1-T2 N 100-255 C?

The cartridge has an impulse current (Iimp) rating of 100 kA with a 10/350 µs waveform, providing high-capacity protection against lightning-current impulses.

What are the discharge current ratings of this ABB surge protection cartridge?

The OVR T1-T2 N 100-255 C has a 25 kA nominal discharge current (In) and a 60 kA maximum discharge current (Imax), measured using an 8/20 µs waveform.

What is the maximum continuous operating voltage of the cartridge?

The ABB OVR T1-T2 N 100-255 C has a maximum continuous operating voltage (Uc) of 255 V AC between neutral and protective earth and a voltage protection level (Up) of 1.5 kV.

Which ABB surge protection devices use the OVR T1-T2 N 100-255 C cartridge?

The OVR T1-T2 N 100-255 C, order code 2CTB813012R2300, is specified by ABB as the replacement cartridge for compatible OVR T1-T2 N 100-255 P and OVR T1-T2 N 100-255 P TS surge protection assemblies.

Trusted Surge Protection from ABB

ABB OVR surge protection devices and replacement cartridges provide coordinated protection for low-voltage electrical installations, helping maintain protection against high-energy lightning currents and damaging transient overvoltages.