2CTB813010R2300 ABB OVR T1-T2 N 100-255 P Surge Protective Device

2CTB813010R2300 ABB OVR T1-T2 N 100-255 P Surge Protective Device

ABB OVR T1-T2 N 100-255 P is a pluggable spark-gap combined Type 1 and Type 2 neutral-to-earth surge protective device for 230/400 V AC TN-S and TT systems, with 100 kA impulse-current capability, 255 V AC maximum continuous operating voltage and a protection level of 1.5 kV or less.

SKU: 2CTB813010R2300MPN: 2CTB813010R2300
Price
List Price £620.94 ex VAT
Your Price (ex VAT) Save 25%
£465.71 25% OFF
You save £155.24 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £465.71
Trade pricing is personalised to your account

Manufacturer Lead Time

£465.71

Why Choose the ABB OVR T1-T2 N 100-255 P Surge Protective Device?

The ABB OVR T1-T2 N 100-255 P, order code 2CTB813010R2300, is a high-capacity combined Type 1 and Type 2 neutral-to-earth surge protective device (SPD) designed for TN-S and TT low-voltage networks. Using spark-gap technology, it is intended for installation in main AC distribution switchboards and sub-distribution boards where substantial lightning-current and transient-overvoltage protection is required.

Designed for 230/400 V AC electrical systems, the OVR T1-T2 N 100-255 P provides an exceptional 100 kA impulse-current capability using the 10/350 µs lightning-current waveform. It also provides a nominal discharge current of 100 kA on the N-PE protection path and limits the voltage protection level to 1.5 kV.

The device provides a dedicated neutral-to-earth (N-PE) protection path with a maximum continuous operating voltage of 255 V AC. Its pluggable construction allows the protection module to be replaced when required, while the compact two-module DIN-rail format makes it straightforward to integrate into coordinated lightning and surge protection systems.

Key Advantages

  • Combined Type 1 + Type 2 / Class I + II protection in a single device.
  • High 100 kA lightning impulse-current capability using a 10/350 µs waveform.
  • Dedicated N-PE protection for TN-S and TT electrical networks.
  • 100 kA nominal discharge current on the neutral-to-earth protection path.
  • Low 1.5 kV voltage protection level helps limit transient stress on downstream equipment.
  • 255 V AC maximum continuous operating voltage.
  • Spark-gap technology designed for high-energy lightning-current discharge.
  • Pluggable construction simplifies maintenance and module replacement.
  • Compact 36 mm width occupies only two DIN-rail modules.

Key Features

  • ABB OVR T1-T2 series.
  • Type 1 + Type 2 / Class I + II SPD.
  • Dedicated neutral-to-earth protection.
  • Suitable for TN-S and TT systems.
  • Single protected N-PE line.
  • Spark-gap protection technology.
  • 100 kA impulse current Iimp using a 10/350 µs waveform.
  • 100 kA nominal discharge current In on the N-PE path.
  • 1.5 kV voltage protection level Up.
  • 255 V AC maximum continuous operating voltage Uc.
  • Response time of less than 100 ns.
  • Pluggable protection module construction.
  • IP20 degree of protection.
  • 35 mm DIN-rail mounting.

High-Capacity Neutral-to-Earth Lightning and Surge Protection

In TN-S and TT electrical systems, the neutral-to-earth protection path plays an important role in a coordinated surge protection arrangement. The ABB OVR T1-T2 N 100-255 P uses spark-gap technology to conduct high-energy lightning currents between neutral and protective earth while maintaining electrical separation during normal operation.

Its exceptional 100 kA 10/350 µs impulse-current capability makes it suitable for demanding lightning protection applications at the origin of an installation. When combined with suitable line protection SPDs, it can form part of a coordinated Type 1 and Type 2 protection system for main switchboards, helping reduce transient stress on downstream distribution equipment and sensitive electronic loads.

Typical Applications

  • Main AC distribution switchboards.
  • Sub-distribution boards requiring high-capacity surge protection.
  • 230/400 V AC TN-S electrical installations.
  • 230/400 V AC TT electrical installations.
  • Commercial and industrial buildings.
  • Manufacturing plants and industrial facilities.
  • Installations equipped with external lightning protection systems.
  • Coordinated line-to-neutral and neutral-to-earth surge protection assemblies.

Technical Specifications

Tick the specs you need, then view products that match.

Remote Signal No
Device Type Surge protection device
SPD Type Type 1+2
Poles 1-pole
Impulse Current Iimp (kA) 100 kA
Series OVR T1-T2
ABB order code 2CTB813010R2300
EAN / GTIN 4053546053234
Product group Surge Protection Devices
Product type Combined Type 1 + Type 2 neutral surge protective device
SPD classification Type 1 + Type 2 / Class I + II
Standards IEC 61643-11 / EN 61643-11 / UL 1449 5th Edition
Technology Spark gap
Low-voltage distribution systems TN-S / TT
Protection mode N-PE
Number of poles 1
Number of protected lines 1
Nominal system voltage 230 / 400 V AC
Maximum continuous operating voltage Uc 255 V AC
System frequency 47–63 Hz
Impulse current Iimp (10/350 µs), N-PE 100 kA
Nominal discharge current In (8/20 µs), N-PE 100 kA
Voltage protection level Up, N-PE ≤ 1.5 kV
Maximum prospective short-circuit current, N-PE 0.1 kA
Follow-current interrupting capability Ifi, N-PE 0.1 kA
Leakage current Ipe <1 mA
Response time <100 ns
TOV withstand, N-PE 1200 V for 200 ms
Remote signalling No
Construction Pluggable
Degree of protection IP20
Maximum operating altitude 2000 m
Operating temperature -40 to +70 °C
Mounting type DIN rail
Module width 2 modules
Dimensions (H × W × D) 90 × 36 × 73 mm
Weight approx. 0.30 kg

Frequently Asked Questions

What is the ABB OVR T1-T2 N 100-255 P used for?

It is a combined Type 1 and Type 2 neutral-to-earth surge protective device designed to discharge high-energy lightning currents and transient surges in TN-S and TT low-voltage electrical systems.

What is the impulse-current rating of the OVR T1-T2 N 100-255 P?

The device has an N-PE impulse-current rating Iimp of 100 kA using the 10/350 µs lightning-current waveform.

What is the voltage protection level of this SPD?

The OVR T1-T2 N 100-255 P provides an N-PE voltage protection level Up of 1.5 kV or less.

Which electrical networks is the OVR T1-T2 N 100-255 P designed for?

It is designed for TN-S and TT low-voltage distribution systems and provides a dedicated neutral-to-earth protection path.

Does the OVR T1-T2 N 100-255 P have remote signalling?

No. ABB order code 2CTB813010R2300 is the version without an auxiliary remote-signalling contact; ABB also offers a separate TS version where remote status signalling is required.

Trusted ABB Lightning and Surge Protection Technology

ABB OVR combined Type 1 and Type 2 surge protective devices provide high-capacity lightning-current discharge and effective transient-overvoltage limitation, with the OVR T1-T2 N 100-255 P delivering dedicated spark-gap neutral-to-earth protection for demanding TN-S and TT electrical installations.