ABB OVR T1-T2 3L 75-255 P TS is a pluggable three-pole combined Type 1 and Type 2 surge protective device for 230/400 V AC TN-C networks, with 25 kA impulse current per pole, 75 kA total impulse-current capability, 60 kA maximum discharge current and remote status signalling.

SKU: 2CTB812751R2300MPN: 2CTB812751R2300
Price
List Price £1,466.55 ex VAT
Your Price (ex VAT) Save 25%
£1,099.91 25% OFF
You save £366.64 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,099.91
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,099.91

Why Choose the ABB OVR T1-T2 3L 75-255 P TS Surge Protective Device?

The ABB OVR T1-T2 3L 75-255 P TS is a high-performance combined Type 1 and Type 2 surge protective device (SPD) designed for three-phase TN-C low-voltage networks. Installed at the origin or main distribution board, it provides protection against high-energy lightning currents and transient overvoltages that could otherwise damage electrical distribution equipment and sensitive downstream loads.

Designed for 230/400 V AC systems, the OVR T1-T2 3L 75-255 P TS provides an impulse current Iimp of 25 kA per pole using the 10/350 µs lightning-current waveform and a total impulse-current capability of 75 kA. It also provides a nominal discharge current of 25 kA and a maximum discharge current of 60 kA using the 8/20 µs waveform.

The device provides three protected poles for L1, L2 and L3 to PEN protection and incorporates pluggable protection modules, visual status indication and TS remote signalling. With a voltage protection level of 1.5 kV, a follow-current interrupting capability of 50 kA and robust DIN-rail construction, it is well suited to demanding commercial and industrial main-distribution applications.

Key Advantages

  • Combined Type 1 + Type 2 protection against lightning currents and transient overvoltages.
  • Purpose-designed for 230/400 V AC TN-C networks.
  • 25 kA impulse current Iimp per pole using a 10/350 µs waveform.
  • 75 kA total impulse-current capability across all three poles.
  • 25 kA nominal discharge current using an 8/20 µs waveform.
  • 60 kA maximum discharge current for high-capacity surge protection.
  • Low 1.5 kV voltage protection level helps safeguard downstream equipment.
  • TS remote signalling contact enables integration with monitoring and alarm systems.
  • Pluggable construction simplifies servicing and replacement.
  • Visual status indication allows convenient local condition monitoring.

Key Features

  • ABB OVR T1-T2 series.
  • Combined Type 1 + Type 2 / Class I + II surge protective device.
  • Three-pole configuration for TN-C electrical systems.
  • L-PEN protection mode.
  • 25 kA impulse current Iimp per pole.
  • 75 kA total impulse current Itotal.
  • 25 kA nominal discharge current In.
  • 60 kA maximum discharge current Imax.
  • 1.5 kV voltage protection level Up.
  • 264 V AC maximum continuous operating voltage Uc.
  • 50 kA follow-current interrupting capability Ifi.
  • Pluggable protection modules with visual status indication.
  • 1 NO + 1 NC auxiliary contacts for remote signalling.
  • 35 mm DIN-rail mounting for main distribution boards and switchgear.

Combined Lightning-Current and Surge Protection for TN-C Networks

Type 1 surge protective devices are designed to conduct the high-energy 10/350 µs impulse currents associated with lightning events, while Type 2 protection limits transient overvoltages represented by the 8/20 µs waveform. The ABB OVR T1-T2 3L 75-255 P TS combines both functions in a single three-pole assembly for coordinated protection at the entrance to a TN-C electrical installation.

Its 75 kA total impulse-current capability, 60 kA maximum discharge current and 1.5 kV protection level provide robust protection for downstream switchgear and electrical equipment. Pluggable construction, local visual indication and TS remote contacts also simplify maintenance and enable the SPD's operating condition to be incorporated into remote monitoring systems.

Typical Applications

  • Main distribution boards in 230/400 V AC installations.
  • Three-phase TN-C electrical distribution systems.
  • Commercial and industrial buildings.
  • Manufacturing plants and industrial facilities.
  • Main switchboards and electrical switchgear assemblies.
  • Installations exposed to lightning-current surges.
  • Protection of downstream automation and electronic equipment.
  • Installations requiring remote SPD status monitoring.

Technical Specifications

Tick the specs you need, then view products that match.

Remote Signal Yes
Device Type Surge protection device
SPD Type Type 1+2
Poles 3-pole
Earthing System TN-C
Impulse Current Iimp (kA) 25 kA
Series OVR T1-T2
ABB order code 2CTB812751R2300
GTIN / EAN 4053546114621
Product group Surge Protection Devices
Product type Combined Type 1 + Type 2 surge protective device
SPD classification Type 1 + Type 2 / Class I + II
Standards IEC 61643-11 / EN 61643-11 / UL 1449 5th Edition
Technology Spark gap
Low-voltage distribution system TN-C
Protection mode L-PEN
Number of poles 3
Number of protected poles 3
Nominal system voltage 230 / 400 V AC
Frequency 47–63 Hz
Maximum continuous operating voltage Uc 264 V AC
Impulse current Iimp per pole (10/350 µs) 25 kA
Total impulse current Itotal (10/350 µs) 75 kA
Nominal discharge current In (8/20 µs) 25 kA
Maximum discharge current Imax (8/20 µs) 60 kA
Follow-current interrupting capability Ifi 50 kA
Voltage protection level Up (L-PE) 1.5 kV
Short-circuit current rating Isccr 50 kA
Maximum overcurrent protection, series connection 125 A gG
Maximum overcurrent protection, parallel connection 315 A gG
Remote signalling Yes
Normally open auxiliary contacts 1
Normally closed auxiliary contacts 1
Remote contact rating 250 V AC / 0.5 A
Status indicator Yes
Construction Pluggable
Protection rating IP20
Operating temperature -40 to +80 °C
Maximum operating altitude 2000 m
Mounting type 35 mm DIN rail
Dimensions (H × W × D) 90 × 108 × 73 mm
Weight approx. 0.9 kg

Frequently Asked Questions

What is the ABB OVR T1-T2 3L 75-255 P TS used for?

It is a combined Type 1 and Type 2 surge protective device designed for main distribution boards in 230/400 V AC TN-C systems, providing protection against lightning currents and transient overvoltages.

What is the lightning impulse-current rating of this SPD?

The OVR T1-T2 3L 75-255 P TS has an impulse current Iimp of 25 kA per pole using a 10/350 µs waveform and a total impulse-current capability of 75 kA.

What are the Type 2 discharge-current ratings?

The device has a nominal discharge current In of 25 kA and a maximum discharge current Imax of 60 kA using an 8/20 µs waveform.

What does TS mean on the OVR T1-T2 3L 75-255 P TS?

The TS version provides remote status signalling through one normally open and one normally closed auxiliary contact, allowing the SPD's operating condition to be connected to suitable monitoring or alarm equipment.

Which electrical network is this SPD designed for?

The OVR T1-T2 3L 75-255 P TS is designed for 230/400 V AC TN-C networks and provides three protected poles in an L-PEN protection arrangement.

Trusted ABB Lightning and Surge Protection Technology

ABB OVR combined Type 1 and Type 2 surge protective devices provide high-capacity lightning-current discharge, effective transient overvoltage limitation, pluggable construction and remote status monitoring for demanding commercial and industrial main-distribution applications.