Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB OVR T1-T2 3L 75-255 P TS is a pluggable three-pole combined Type 1 and Type 2 surge protective device for 230/400 V AC TN-C networks, with 25 kA impulse current per pole, 75 kA total impulse-current capability, 60 kA maximum discharge current and remote status signalling.
£1,099.91
The ABB OVR T1-T2 3L 75-255 P TS is a high-performance combined Type 1 and Type 2 surge protective device (SPD) designed for three-phase TN-C low-voltage networks. Installed at the origin or main distribution board, it provides protection against high-energy lightning currents and transient overvoltages that could otherwise damage electrical distribution equipment and sensitive downstream loads.
Designed for 230/400 V AC systems, the OVR T1-T2 3L 75-255 P TS provides an impulse current Iimp of 25 kA per pole using the 10/350 µs lightning-current waveform and a total impulse-current capability of 75 kA. It also provides a nominal discharge current of 25 kA and a maximum discharge current of 60 kA using the 8/20 µs waveform.
The device provides three protected poles for L1, L2 and L3 to PEN protection and incorporates pluggable protection modules, visual status indication and TS remote signalling. With a voltage protection level of 1.5 kV, a follow-current interrupting capability of 50 kA and robust DIN-rail construction, it is well suited to demanding commercial and industrial main-distribution applications.
Type 1 surge protective devices are designed to conduct the high-energy 10/350 µs impulse currents associated with lightning events, while Type 2 protection limits transient overvoltages represented by the 8/20 µs waveform. The ABB OVR T1-T2 3L 75-255 P TS combines both functions in a single three-pole assembly for coordinated protection at the entrance to a TN-C electrical installation.
Its 75 kA total impulse-current capability, 60 kA maximum discharge current and 1.5 kV protection level provide robust protection for downstream switchgear and electrical equipment. Pluggable construction, local visual indication and TS remote contacts also simplify maintenance and enable the SPD's operating condition to be incorporated into remote monitoring systems.
Tick the specs you need, then view products that match.
| Remote Signal | Yes | |
|---|---|---|
| Device Type | Surge protection device | |
| SPD Type | Type 1+2 | |
| Poles | 3-pole | |
| Earthing System | TN-C | |
| Impulse Current Iimp (kA) | 25 kA | |
| Series | OVR T1-T2 | |
| ABB order code | 2CTB812751R2300 | |
| GTIN / EAN | 4053546114621 | |
| Product group | Surge Protection Devices | |
| Product type | Combined Type 1 + Type 2 surge protective device | |
| SPD classification | Type 1 + Type 2 / Class I + II | |
| Standards | IEC 61643-11 / EN 61643-11 / UL 1449 5th Edition | |
| Technology | Spark gap | |
| Low-voltage distribution system | TN-C | |
| Protection mode | L-PEN | |
| Number of poles | 3 | |
| Number of protected poles | 3 | |
| Nominal system voltage | 230 / 400 V AC | |
| Frequency | 47–63 Hz | |
| Maximum continuous operating voltage Uc | 264 V AC | |
| Impulse current Iimp per pole (10/350 µs) | 25 kA | |
| Total impulse current Itotal (10/350 µs) | 75 kA | |
| Nominal discharge current In (8/20 µs) | 25 kA | |
| Maximum discharge current Imax (8/20 µs) | 60 kA | |
| Follow-current interrupting capability Ifi | 50 kA | |
| Voltage protection level Up (L-PE) | 1.5 kV | |
| Short-circuit current rating Isccr | 50 kA | |
| Maximum overcurrent protection, series connection | 125 A gG | |
| Maximum overcurrent protection, parallel connection | 315 A gG | |
| Remote signalling | Yes | |
| Normally open auxiliary contacts | 1 | |
| Normally closed auxiliary contacts | 1 | |
| Remote contact rating | 250 V AC / 0.5 A | |
| Status indicator | Yes | |
| Construction | Pluggable | |
| Protection rating | IP20 | |
| Operating temperature | -40 to +80 °C | |
| Maximum operating altitude | 2000 m | |
| Mounting type | 35 mm DIN rail | |
| Dimensions (H × W × D) | 90 × 108 × 73 mm | |
| Weight | approx. 0.9 kg |
It is a combined Type 1 and Type 2 surge protective device designed for main distribution boards in 230/400 V AC TN-C systems, providing protection against lightning currents and transient overvoltages.
The OVR T1-T2 3L 75-255 P TS has an impulse current Iimp of 25 kA per pole using a 10/350 µs waveform and a total impulse-current capability of 75 kA.
The device has a nominal discharge current In of 25 kA and a maximum discharge current Imax of 60 kA using an 8/20 µs waveform.
The TS version provides remote status signalling through one normally open and one normally closed auxiliary contact, allowing the SPD's operating condition to be connected to suitable monitoring or alarm equipment.
The OVR T1-T2 3L 75-255 P TS is designed for 230/400 V AC TN-C networks and provides three protected poles in an L-PEN protection arrangement.
ABB OVR combined Type 1 and Type 2 surge protective devices provide high-capacity lightning-current discharge, effective transient overvoltage limitation, pluggable construction and remote status monitoring for demanding commercial and industrial main-distribution applications.
We use cookies