2CTB812511R2300 ABB OVR T1-T2 1N 50-255 P TS Surge Protective Device

2CTB812511R2300 ABB OVR T1-T2 1N 50-255 P TS Surge Protective Device

ABB OVR T1-T2 1N 50-255 P TS combined Type 1 and Type 2 pluggable surge protective device for 230 V AC TT and TN-S single-phase plus neutral systems, with 25 kA L-N impulse current, 50 kA N-PE lightning-current capability and remote signalling.

SKU: 2CTB812511R2300MPN: 2CTB812511R2300
Price
List Price £898.47 ex VAT
Your Price (ex VAT) Save 25%
£673.85 25% OFF
You save £224.62 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £673.85
Trade pricing is personalised to your account

Manufacturer Lead Time

£673.85

Why Choose the ABB OVR T1-T2 1N 50-255 P TS Surge Protective Device?

The ABB OVR T1-T2 1N 50-255 P TS is a combined Type 1 + Type 2 surge protective device (SPD) designed to protect single-phase plus neutral low-voltage electrical installations against lightning currents and transient overvoltages. Identified by ABB order code 2CTB812511R2300, it provides 1P+N protection for 230 V AC TT and TN-S networks.

The device uses a 1+1 protection configuration, combining a 25 kA L-N protection path with a high-capacity 50 kA N-PE protection path. Its spark-gap technology is designed for installation where substantial lightning-current capability is required, while the low voltage protection level helps reduce electrical stress on downstream equipment.

The OVR T1-T2 1N 50-255 P TS provides an impulse discharge current (Iimp) of 25 kA L-N and 50 kA N-PE using a 10/350 µs waveform, with a 50 kA total lightning-current capability. Its pluggable construction, visual status indication and integrated TS remote signalling contact provide convenient maintenance and condition monitoring for demanding building, commercial and industrial installations.

Key Advantages

  • Combined Type 1 + Type 2 protection against lightning currents and transient overvoltages.
  • Designed for 230 V AC single-phase plus neutral TT and TN-S systems.
  • 25 kA L-N impulse discharge current (Iimp) using a 10/350 µs waveform.
  • 50 kA N-PE impulse discharge current and 50 kA total lightning-current capability.
  • 25 kA nominal discharge current (In) for Type 2 surge protection.
  • 1.5 kV voltage protection level across the L-N and N-PE protection paths.
  • Pluggable protection cartridges simplify maintenance and replacement.
  • TS remote signalling enables external monitoring of SPD condition.

Key Features

  • ABB OVR T1-T2 surge protection range.
  • Type 1 / Class I + Type 2 / Class II SPD.
  • 1P+N / 1+1 protection configuration.
  • 230 V AC nominal voltage, 50/60 Hz.
  • 264 V AC L-N maximum continuous operating voltage (Uc).
  • 255 V AC N-PE maximum continuous operating voltage.
  • 25 kA L-N impulse discharge current (Iimp, 10/350 µs).
  • 50 kA N-PE impulse discharge current (Iimp, 10/350 µs).
  • 50 kA total discharge current (Itotal, 10/350 µs).
  • 25 kA nominal discharge current (In, 8/20 µs).
  • 1.5 kV L-N and N-PE voltage protection level (Up).
  • Spark-gap surge protection technology.
  • Visual status indication plus 1NO + 1NC remote signalling contact.
  • Pluggable modular construction for DIN rail mounting.

Reliable Type 1 and Type 2 Protection for Single-Phase Systems

Combined Type 1 and Type 2 surge protective devices provide coordinated protection against both high-energy lightning currents and transient overvoltages. Type 1 capability is evaluated using the 10/350 µs lightning-current waveform, while Type 2 performance addresses 8/20 µs surge currents that can arise from indirect lightning effects and electrical switching operations.

The ABB OVR T1-T2 1N 50-255 P TS combines a 25 kA L-N lightning impulse rating with a 50 kA N-PE discharge path in a compact 1P+N assembly. Replaceable protection cartridges simplify servicing, while local status indication and the TS changeover contact allow protection condition to be checked locally or incorporated into a remote monitoring system.

Typical Applications

  • 230 V AC single-phase electrical installations.
  • TT and TN-S low-voltage distribution systems.
  • Main low-voltage distribution boards.
  • Commercial and industrial electrical panels.
  • Building electrical distribution systems.
  • Installations requiring combined Type 1 and Type 2 lightning and surge protection.
  • Systems requiring remote monitoring of surge protective device status.

Technical Specifications

Tick the specs you need, then view products that match.

Remote Signal Yes
Device Type Surge protection device
SPD Type Type 1+2
Poles 1-pole + N
Earthing System TN-S, TT
Impulse Current Iimp (kA) 25 kA
Series OVR T1-T2
ABB order code 2CTB812511R2300
Product group Surge Protection Devices
Product type Combined lightning-current and surge protective device
SPD classification Type 1 + Type 2 / Class I + Class II
Technology Spark gap
Protection configuration 1+1 / 1P+N
Number of poles 2
Number of protected poles 2
Low-voltage distribution systems TT / TN-S
Nominal voltage 230 V AC
Frequency 50/60 Hz
Maximum continuous operating voltage (L-N) 264 V AC
Maximum continuous operating voltage (N-PE) 255 V AC
Impulse discharge current (Iimp, L-N, 10/350 µs) 25 kA
Impulse discharge current (Iimp, N-PE, 10/350 µs) 50 kA
Total discharge current (Itotal, 10/350 µs) 50 kA
Nominal discharge current (In, 8/20 µs) 25 kA
Voltage protection level (Up, L-N) ≤1.5 kV
Voltage protection level (Up, N-PE) ≤1.5 kV
Short-circuit withstand 100 kA
Maximum series backup fuse 125 A gG
Maximum parallel backup fuse 315 A gG
Remote signalling Yes
Auxiliary contacts 1NO + 1NC
Remote contact rating 250 V AC / 0.5 A
Status indicator Yes
Protection rating IP20
Operating temperature -40 to +80 °C
Maximum operating altitude 2000 m
Mounting 35 mm DIN rail
Construction Pluggable
Standards IEC 61643-11 / EN 61643-11 / UL 1449 5th Edition
Dimensions (H × W × D) 90 × 72 × 73 mm
L-N replacement cartridge OVR T1-T2 1L 25-255 C
N-PE replacement cartridge OVR T1-T2 N 50-255 C

Frequently Asked Questions

What is the ABB OVR T1-T2 1N 50-255 P TS used for?

It is a combined Type 1 and Type 2 surge protective device designed to protect 230 V AC single-phase plus neutral TT and TN-S installations against lightning currents and transient overvoltages.

What is the lightning impulse current rating?

The device provides an impulse discharge current (Iimp) of 25 kA on the L-N path and 50 kA on the N-PE path using a 10/350 µs waveform, with a total lightning-current discharge capability of 50 kA.

What is the voltage protection level?

The OVR T1-T2 1N 50-255 P TS provides a voltage protection level (Up) of ≤1.5 kV across L-N and N-PE, helping limit transient voltage reaching downstream equipment.

What does TS mean on the OVR T1-T2 1N 50-255 P TS?

The TS designation indicates remote signalling. The SPD incorporates a 1NO + 1NC auxiliary contact so its operating condition can be monitored remotely.

Can the protection cartridges be replaced?

Yes. The device uses pluggable protection cartridges. The L-N protection module is the OVR T1-T2 1L 25-255 C and the N-PE protection module is the OVR T1-T2 N 50-255 C.

Trusted Lightning and Surge Protection from ABB

ABB OVR combined Type 1 and Type 2 surge protective devices provide high-capacity lightning-current and transient overvoltage protection for low-voltage electrical installations, with replaceable modules and remote status signalling to support dependable system protection.