Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB OVR T2-T3 N 80-275 P QS is a pluggable single-pole neutral surge protection device with 80 kA maximum discharge current, 30 kA nominal discharge current and 275 V AC maximum continuous operating voltage for compatible TT and TN-S low-voltage electrical installations.
£80.76
The ABB OVR T2-T3 N 80-275 P QS, order code 2CTB803973R1900, is a pluggable surge protection device (SPD) designed to protect low-voltage electrical installations against transient overvoltages caused by indirect lightning and electrical switching events. As part of the ABB OVR QuickSafe surge protection range, this single-pole neutral protection device combines high surge-current handling capability with a compact DIN rail format for electrical distribution applications.
Designed for 230/400 V AC TT and TN-S networks, the OVR T2-T3 N 80-275 P QS provides a maximum discharge current (Imax) of 80 kA and a nominal discharge current (In) of 30 kA. Its 1.4 kV voltage protection level (Up) helps limit transient overvoltages reaching downstream electrical and electronic equipment.
With a 275 V AC maximum continuous operating voltage, pluggable construction and a compact one-module design, the OVR T2-T3 N 80-275 P QS is suitable for installation in compatible electrical distribution boards. Its high discharge capacity makes it particularly useful as the neutral protection element within coordinated surge protection arrangements for residential, commercial and industrial installations.
Surge protection devices help safeguard low-voltage electrical installations by diverting transient surge currents and limiting the voltage reaching connected equipment. High-capacity protection is particularly important where electrical systems may be exposed to transient overvoltages generated by indirect lightning activity or switching operations within the power distribution network.
The ABB OVR T2-T3 N 80-275 P QS is designed as a neutral protection element for compatible TT and TN-S systems. Its high discharge-current capability, low voltage protection level and pluggable QuickSafe construction make it suitable for coordinated surge protection installations where dependable performance and straightforward maintenance are required.
Tick the specs you need, then view products that match.
| Remote Signal | No | |
|---|---|---|
| Device Type | Surge protection device | |
| SPD Type | Type 2+3 | |
| Poles | 1-pole | |
| Impulse Current Iimp (kA) | 6.25 kA | |
| Series | OVR QuickSafe | |
| Order code / MPN | 2CTB803973R1900 | |
| Product group | Surge Protection Devices | |
| Product type | Surge protection device | |
| Protection configuration | Neutral, single pole | |
| Number of poles | 1 | |
| Number of protected poles | 1 | |
| Nominal system voltage | 230/400 V AC | |
| Maximum continuous operating voltage (Uc) | 275 V AC | |
| Nominal discharge current (In, 8/20 µs) | 30 kA | |
| Maximum discharge current (Imax, 8/20 µs) | 80 kA | |
| Impulse current (Iimp, 10/350 µs) | 6.25 kA | |
| Voltage protection level (Up) | 1.4 kV | |
| Voltage protection level (N-PE) | 1.4 kV | |
| Distribution systems | TT, TN-S | |
| Short-circuit withstand (Icc) | 100 kA | |
| Rated service short-circuit breaking capacity (Ics) | 100 kA | |
| Maximum backup protection | 125 A fuse or MCB | |
| Status indicator | No | |
| Preventive maintenance function | No | |
| Mounting type | DIN rail | |
| Module width | 1 module | |
| Protection rating | IP20 | |
| Maximum operating altitude | 5000 m | |
| Standards | IEC 61643-11 / EN 61643-11 | |
| Dimensions (H × W × D) | 88 × 17.8 × 58 mm | |
| Weight | 0.12 kg | |
| Construction | Pluggable |
The ABB OVR T2-T3 N 80-275 P QS is a single-pole neutral surge protection device designed to protect compatible low-voltage electrical installations against transient overvoltages caused by indirect lightning and electrical switching events.
The device has a maximum discharge current (Imax) of 80 kA with an 8/20 µs waveform and a nominal discharge current (In) of 30 kA.
The ABB OVR T2-T3 N 80-275 P QS has a maximum continuous operating voltage (Uc) of 275 V AC and is intended for compatible 230/400 V AC electrical systems.
The OVR T2-T3 N 80-275 P QS provides a voltage protection level (Up) of 1.4 kV, helping limit transient overvoltages reaching downstream electrical equipment.
The device is designed for DIN rail installation in compatible electrical distribution boards and is suitable for neutral protection within TT and TN-S low-voltage surge protection systems.
ABB OVR QuickSafe surge protection devices provide dependable protection for low-voltage electrical installations, helping safeguard residential, commercial and industrial electrical systems against damaging transient overvoltages.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.