Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB OVR T2 3N 40-275 P TS QS is a pluggable Type 2 surge protection device with 40 kA maximum discharge current, 20 kA nominal discharge current, 275 V AC maximum continuous operating voltage and remote signalling for 230/400 V TT and TN-S electrical installations.
£337.68
The ABB OVR T2 3N 40-275 P TS QS, order code 2CTB803973R0500, is a pluggable Type 2 surge protection device (SPD) designed to protect low-voltage electrical installations and sensitive equipment against transient overvoltages caused by indirect lightning and electrical switching events. As part of the ABB OVR QuickSafe surge protection range, it provides dependable surge protection for three-phase plus neutral electrical distribution systems.
Designed for 230/400 V AC TT and TN-S networks, this SPD uses a 3+1 protection configuration and provides a maximum discharge current (Imax) of 40 kA and a nominal discharge current (In) of 20 kA. Its 1.5 kV voltage protection level (Up) helps limit transient overvoltages reaching downstream electrical and electronic equipment.
The OVR T2 3N 40-275 P TS QS has a 275 V AC maximum continuous operating voltage and features pluggable protection cartridges, visual status indication and remote signalling auxiliary contacts. Its four-pole DIN rail format makes it suitable for integration into residential, commercial and industrial electrical distribution boards where reliable three-phase surge protection and remote status monitoring are required.
Type 2 surge protection devices protect low-voltage electrical installations and sensitive equipment against transient overvoltages associated with indirect lightning and switching events. They are designed to safely discharge surge currents characterised by an 8/20 µs waveform while limiting the residual voltage reaching downstream equipment.
The ABB OVR T2 3N 40-275 P TS QS combines three-phase plus neutral protection with pluggable construction, visual status indication and remote signalling. These features make it suitable for distribution boards where dependable surge protection, straightforward maintenance and remote monitoring of protection status are required.
Tick the specs you need, then view products that match.
| Remote Signal | Yes | |
|---|---|---|
| SPD Type | Type 2 | |
| Poles | 3-pole + N | |
| Earthing System | TN-S, TT | |
| Device Type | Surge protection device | |
| Impulse Current Iimp (kA) | 2 kA | |
| Series | OVR QuickSafe | |
| Order code / MPN | 2CTB803973R0500 | |
| Product group | Surge Protection Devices | |
| Product type | Type 2 surge protection device | |
| SPD classification | Type 2 | |
| Protection configuration | 3+1 | |
| Number of poles | 4 | |
| Number of protected poles | 4 | |
| Nominal voltage | 230 V AC | |
| Nominal system voltage | 230/400 V AC | |
| Maximum continuous operating voltage (Uc) | 275 V AC | |
| Nominal discharge current (In, 8/20 µs) | 20 kA | |
| Maximum discharge current (Imax, 8/20 µs) | 40 kA | |
| Impulse current (Iimp, 10/350 µs) | 2 kA | |
| Voltage protection level (Up) | 1.5 kV | |
| Voltage protection level (L-N) | 1.25 kV | |
| Voltage protection level (N-PE) | 1.4 kV | |
| Distribution systems | TT, TN-S | |
| Auxiliary contacts | 1 NO + 1 NC | |
| Status indicator | Yes | |
| Mounting type | DIN rail | |
| Module width | 4 modules | |
| Protection rating | IP20 | |
| Maximum operating altitude | 5000 m | |
| Rated service short-circuit breaking capacity (Ics) | 100 kA | |
| Short-circuit withstand (Icc) | 100 kA | |
| Power loss | 29 mW | |
| Standards | IEC 61643-11 / EN 61643-11 | |
| Dimensions (H × W × D) | 95 × 71.2 × 58 mm | |
| Weight | 0.48 kg | |
| Construction | Pluggable |
The ABB OVR T2 3N 40-275 P TS QS is a Type 2 surge protection device designed to protect 230/400 V three-phase plus neutral electrical installations and sensitive equipment against transient overvoltages caused by indirect lightning and switching events.
The device has a maximum discharge current (Imax) of 40 kA with an 8/20 µs waveform and a nominal discharge current (In) of 20 kA.
The ABB OVR T2 3N 40-275 P TS QS has a maximum continuous operating voltage (Uc) of 275 V AC and is designed for 230/400 V AC systems.
Yes. The TS version includes auxiliary contacts for remote signalling, with one normally open and one normally closed contact for monitoring the SPD status.
The device is designed for DIN rail installation in electrical distribution boards and is suitable for three-phase plus neutral TT and TN-S networks in residential, commercial and industrial applications.
ABB OVR QuickSafe surge protection devices provide dependable protection for low-voltage electrical installations, helping safeguard residential, commercial and industrial electrical systems and sensitive equipment against damaging transient overvoltages.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.