2CTB803972R0500 ABB OVR T2 1N 40-275 P TS QS Type 2 Surge Protective Device

2CTB803972R0500 ABB OVR T2 1N 40-275 P TS QS Type 2 Surge Protective Device

ABB OVR T2 1N 40-275 P TS QS Type 2 pluggable 1P+N surge protective device for 230 V AC TT and TN-S systems, with 275 V AC maximum continuous operating voltage, 20 kA nominal discharge current, 40 kA maximum discharge current and remote signalling.

SKU: 2CTB803972R0500MPN: 2CTB803972R0500
Price
List Price £243.35 ex VAT
Your Price (ex VAT) Save 25%
£182.51 25% OFF
You save £60.84 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £182.51
Trade pricing is personalised to your account

Manufacturer Lead Time

£182.51

Why Choose the ABB OVR T2 1N 40-275 P TS QS Surge Protective Device?

The ABB OVR T2 1N 40-275 P TS QS is a high-performance Type 2 surge protective device (SPD) designed to protect low-voltage electrical installations against transient overvoltages caused by indirect lightning strikes and switching events. Identified by ABB order code 2CTB803972R0500, it is designed for single-phase plus neutral applications in TT and TN-S networks.

As part of the ABB OVR Type 2 QuickSafe surge protection range, this device combines pluggable protection cartridges with ABB QuickSafe technology for dependable protection and straightforward maintenance. The TS auxiliary contact provides remote status signalling, allowing the condition of the surge protective device to be integrated into monitoring or building management systems.

The OVR T2 1N 40-275 P TS QS is designed for 230 V AC single-phase plus neutral systems, with a maximum continuous operating voltage of 275 V AC. It provides a 20 kA nominal discharge current (In) and 40 kA maximum discharge current (Imax) using the standard 8/20 µs surge waveform, with a voltage protection level of 1.25 kV.

Key Advantages

  • High-performance Type 2 surge protection for 1P+N electrical systems.
  • 40 kA maximum discharge current (Imax) for effective transient overvoltage protection.
  • 20 kA nominal discharge current (In) using an 8/20 µs waveform.
  • 275 V AC maximum continuous operating voltage for 230 V networks.
  • Low 1.25 kV voltage protection level (Up) helps protect sensitive downstream equipment.
  • Integrated TS auxiliary contact enables remote monitoring of SPD status.
  • Pluggable protection cartridges simplify inspection and replacement.
  • Compatible with ABB System pro M compact modular equipment.

Key Features

  • ABB OVR Type 2 QuickSafe surge protection series.
  • Type 2 / Class II surge protective device.
  • 1P+N / 1+1 configuration with two poles.
  • 230 V AC nominal system voltage.
  • 275 V AC maximum continuous operating voltage (Uc).
  • 20 kA nominal discharge current (In, 8/20 µs).
  • 40 kA maximum discharge current (Imax, 8/20 µs).
  • 1.25 kV voltage protection level (Up).
  • Integrated auxiliary changeover signalling contact.
  • Pluggable modules for convenient maintenance.
  • 35 mm DIN rail mounting for modular distribution boards.
  • Suitable for TT and TN-S electrical networks.

Reliable Type 2 Protection for Electrical Distribution Systems

Type 2 surge protective devices are designed to discharge surge currents produced by indirect lightning strikes and switching operations before damaging transient voltages can reach downstream electrical equipment. Installed in main or sub-distribution boards, they provide an important level of protection for sensitive electronic, control and automation equipment.

The ABB OVR T2 1N 40-275 P TS QS combines high surge-current handling capability with a low residual protection voltage and pluggable construction. Its remote signalling contact allows SPD condition monitoring, while its modular DIN rail format makes it well suited to modern electrical distribution boards and ABB System pro M compact installations.

Typical Applications

  • Single-phase 230 V AC electrical distribution boards.
  • TT and TN-S low-voltage electrical installations.
  • Commercial and industrial distribution systems.
  • Building electrical distribution and infrastructure.
  • Industrial control panels and automation equipment.
  • Protection of electronic controls and sensitive electrical loads.
  • Main and sub-distribution boards requiring remote SPD status monitoring.

Technical Specifications

Tick the specs you need, then view products that match.

Remote Signal Yes
Device Type Surge protection device
SPD Type Type 2
Poles 1-pole + N
Earthing System TN-S, TT
Series OVR T2 QuickSafe
ABB order code 2CTB803972R0500
Product group Surge Protection Devices
Product type Surge protective device (SPD)
SPD classification Type 2 / Class II
Configuration 1P+N / 1+1
Number of poles 2
Nominal system voltage 230 V AC
Maximum continuous operating voltage (Uc) 275 V AC
Nominal discharge current (In, 8/20 µs) 20 kA
Maximum discharge current (Imax, 8/20 µs) 40 kA
Voltage protection level (Up) 1.25 kV
Network systems TT / TN-S
Auxiliary contact Yes, TS remote signalling contact
Module type Pluggable
Mounting 35 mm DIN rail
Standards IEC 61643-11 / EN 61643-11
Dimensions (H × W × D) approx. 95.8 × 35.6 × 65.3 mm
EAN 3660308519702

Frequently Asked Questions

What is the ABB OVR T2 1N 40-275 P TS QS used for?

It is a Type 2 surge protective device designed to protect 230 V single-phase plus neutral electrical installations against transient overvoltages caused by indirect lightning and switching events.

What is the maximum discharge current of this SPD?

The OVR T2 1N 40-275 P TS QS has a maximum discharge current (Imax) of 40 kA using an 8/20 µs waveform.

What is the maximum continuous operating voltage?

The maximum continuous operating voltage (Uc) is 275 V AC, making the device suitable for 230 V AC single-phase plus neutral systems.

What does TS mean on the OVR T2 1N 40-275 P TS QS?

The TS designation indicates remote signalling capability through an integrated auxiliary contact, allowing the status of the surge protective device to be monitored remotely.

Can the protection modules be replaced?

Yes. The ABB OVR T2 1N 40-275 P TS QS uses pluggable protection modules, allowing replacement without removing the complete DIN rail base from the distribution board.

Trusted Surge Protection from ABB

ABB OVR QuickSafe surge protective devices provide dependable protection for low-voltage distribution systems, combining high surge-current capability, modular installation and convenient monitoring for industrial, commercial and building applications.