Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB OVR T2 4L 40-440 P TS QS four-line pluggable QuickSafe Type 2 surge protective device with 440 V AC maximum continuous operating voltage, 40 kA maximum discharge current, 20 kA nominal discharge current and remote signalling.
£356.81
The ABB OVR T2 4L 40-440 P TS QS is a four-pole Type 2 surge protective device (SPD) designed to protect low-voltage electrical installations and sensitive equipment against transient overvoltages caused by indirect lightning effects and switching events. Part of the ABB OVR QuickSafe surge protection range, it is designed for three-phase systems requiring protection across four conductors and combines high surge-current capability with pluggable DIN-rail construction.
The OVR T2 4L 40-440 P TS QS provides a maximum discharge current (Imax) of 40 kA and a nominal discharge current (In) of 20 kA using the standard 8/20 µs surge-current waveform. It has a 440 V AC maximum continuous operating voltage (Uc) and a 1.8 kV voltage protection level (Up), providing effective transient overvoltage protection for compatible three-phase power-distribution systems.
Its pluggable QuickSafe construction allows individual protection cartridges to be replaced without changing the complete SPD base. The TS remote signalling function enables external monitoring of device status, while integrated thermal disconnectors and end-of-life indication support straightforward inspection and maintenance. The four-pole configuration is particularly suitable for TNS and compatible IT network applications.
Type 2 surge protective devices are designed to divert surge currents generated by indirect lightning effects and switching operations while limiting the transient overvoltage reaching downstream electrical and electronic equipment. Their ability to discharge currents characterised by an 8/20 µs waveform makes them an important part of coordinated surge protection in low-voltage distribution systems.
The ABB OVR T2 4L 40-440 P TS QS combines 40 kA maximum discharge capability, 20 kA nominal discharge current and a 1.8 kV protection level with four-line QuickSafe construction. Pluggable cartridges, integrated status indication and remote signalling make it particularly practical for industrial and commercial installations where surge protection must be monitored and maintained efficiently.
Tick the specs you need, then view products that match.
| Remote Signal | Yes | |
|---|---|---|
| SPD Type | Type 2 | |
| Poles | 4-pole | |
| Earthing System | TN-S | |
| Device Type | Surge protection device | |
| Impulse Current Iimp (kA) | 2 kA | |
| Series | OVR T2 QuickSafe | |
| ABB order code | 2CTB803873R5300 | |
| Product group | Surge Protection Devices | |
| Product type | Type 2 surge protective device | |
| Test class | Class II | |
| Number of protected lines | 4 | |
| Network applications | TNS / IT | |
| Rated voltage | 400 V AC | |
| Maximum continuous operating voltage (Uc) | 440 V AC | |
| Maximum discharge current (Imax, 8/20 µs) | 40 kA | |
| Nominal discharge current (In, 8/20 µs) | 20 kA | |
| Impulse current (Iimp, 10/350 µs) | 2 kA | |
| Voltage protection level (Up) | 1.8 kV | |
| Short-circuit rating | 100 kA | |
| Technology | QuickSafe | |
| Construction | Pluggable | |
| Integrated thermal disconnector | Yes | |
| End-of-life indicator | Yes | |
| Remote signalling | Yes | |
| Maximum backup protection | 125 A fuse or MCB | |
| Mounting type | DIN rail | |
| Width | 71.2 mm | |
| Net weight | approx. 0.45 kg | |
| Standards | IEC 61643-11 / EN 61643-11 |
It is a four-line Type 2 surge protective device designed to protect compatible three-phase low-voltage electrical installations and connected equipment against transient overvoltages caused by indirect lightning effects and switching events.
The device has a maximum discharge current (Imax) of 40 kA and a nominal discharge current (In) of 20 kA, based on the 8/20 µs surge-current waveform.
The ABB OVR T2 4L 40-440 P TS QS has a maximum continuous operating voltage (Uc) of 440 V AC and a voltage protection level (Up) of 1.8 kV.
Yes. The TS version incorporates remote signalling for external monitoring of the operating condition of the surge protective device.
Yes. The OVR T2 4L 40-440 P TS QS has a pluggable construction, allowing protection cartridges to be replaced during maintenance without replacing the complete SPD base.
ABB OVR QuickSafe surge protective devices provide dependable transient overvoltage protection for low-voltage electrical systems, combining high surge discharge capability with pluggable construction, compact DIN-rail installation and practical local and remote status monitoring.