2CTB803873R2500 ABB OVR T2 3L 40-275 P TS QS Type 2 Surge Protective Device

2CTB803873R2500 ABB OVR T2 3L 40-275 P TS QS Type 2 Surge Protective Device

ABB OVR T2 3L 40-275 P TS QS 2CTB803873R2500 is a three-pole pluggable Type 2 surge protective device for 230/400 V AC TN-C networks with a 40 kA maximum discharge current, 20 kA nominal discharge current, 275 V maximum continuous operating voltage and auxiliary signalling contact.

SKU: 2CTB803873R2500MPN: 2CTB803873R2500
Price
List Price £328.66 ex VAT
Your Price (ex VAT) Save 25%
£246.50 25% OFF
You save £82.17 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £246.50
Trade pricing is personalised to your account

Manufacturer Lead Time

£246.50

Why Choose the ABB OVR T2 3L 40-275 P TS QS Surge Protective Device?

The ABB OVR T2 3L 40-275 P TS QS, order code 2CTB803873R2500, is a three-pole, pluggable Type 2 surge protective device (SPD) designed to protect low-voltage electrical installations and sensitive equipment against transient overvoltages caused by indirect lightning effects and switching events. Part of the ABB OVR range and ABB's Surge Protection Devices product group, it is designed for three-phase 230/400 V AC TN-C networks.

The OVR T2 3L 40-275 P TS QS provides a maximum discharge current (Imax) of 40 kA and a nominal discharge current (In) of 20 kA using an 8/20 µs surge current waveform. Its 1.25 kV voltage protection level (Up) helps limit transient voltage reaching downstream equipment, while the 275 V AC maximum continuous operating voltage (Uc) is suited to 230/400 V AC three-phase systems.

Featuring replaceable pluggable protection modules, ABB QuickSafe technology, mechanical status indication and an auxiliary signalling contact, this SPD combines robust surge protection with convenient local and remote monitoring. Its three-module DIN-rail format makes it well suited to industrial and commercial distribution boards where dependable three-phase surge protection and efficient maintenance are required.

Key Advantages

  • Dedicated three-pole Type 2 surge protection for three-phase electrical installations.
  • 40 kA maximum discharge current (Imax) with an 8/20 µs waveform.
  • 20 kA nominal discharge current (In) for robust transient surge protection.
  • 1.25 kV voltage protection level (Up) helps reduce voltage stress on downstream equipment.
  • Designed for 230/400 V AC TN-C networks.
  • 275 V AC maximum continuous operating voltage (Uc).
  • Pluggable protection modules support straightforward inspection and replacement.
  • QuickSafe technology provides integrated protection-module disconnection.
  • Auxiliary contact enables remote SPD status monitoring.

Key Features

  • ABB OVR Type 2 surge protection range.
  • Three-pole Type 2 SPD.
  • Three protected lines.
  • 230/400 V AC nominal system voltage.
  • 275 V AC maximum continuous operating voltage.
  • 40 kA Imax maximum discharge current.
  • 20 kA In nominal discharge current.
  • 1.25 kV Up voltage protection level at In.
  • QuickSafe technology.
  • Replaceable pluggable protection modules.
  • Mechanical visual status indication.
  • TS auxiliary contact for remote status indication.
  • Fast response time of ≤25 ns.
  • DIN-rail mounting for straightforward integration into distribution equipment.

Reliable Three-Phase Type 2 Protection with Remote Signalling

Type 2 surge protective devices are installed in low-voltage distribution systems to limit transient overvoltages generated by indirect lightning effects and electrical switching operations. The ABB OVR T2 range safely discharges surge currents with an 8/20 µs waveform, helping reduce the voltage stress applied to sensitive electrical and electronic equipment.

The OVR T2 3L 40-275 P TS QS combines three-line protection with a substantial 40 kA maximum discharge capability, QuickSafe technology, replaceable protection modules and an auxiliary signalling contact. This combination makes it particularly suitable for three-phase TN-C distribution systems where compact surge protection, straightforward maintenance and remote condition monitoring are required.

Typical Applications

  • 230/400 V AC three-phase TN-C electrical networks.
  • Industrial electrical distribution boards.
  • Commercial building electrical systems.
  • Industrial control and automation panels.
  • Manufacturing and production facilities.
  • Systems requiring remote SPD status monitoring.
  • Protection of sensitive three-phase electrical and electronic equipment.
  • Secondary protection against indirect lightning and switching surges.

Technical Specifications

Tick the specs you need, then view products that match.

Remote Signal Yes
SPD Type Type 2
Poles 3-pole
Earthing System TN-C
Device Type Surge protection device
Series OVR
Order code 2CTB803873R2500
Product group Surge Protection Devices
Product type Type 2 surge protective device
Type / test class T2 / Class II
Number of poles 3
Protected lines 3
Network type TN-C
Type of current AC, 45–65 Hz
Nominal system voltage 230/400 V AC
Maximum continuous operating voltage (Uc) 275 V AC
Maximum discharge current (Imax) 40 kA
Nominal discharge current (In) 20 kA
Discharge current waveform 8/20 µs
Voltage protection level (Up) at In 1.25 kV
Response time ≤25 ns
Short-circuit withstand capability (Isccr) 100 kA
Maximum backup fuse 125 A
Maximum circuit breaker 125 A
Protection technology QuickSafe
Construction Pluggable
Status indication Mechanical visual indicator
Auxiliary contact Yes
Solid conductor range 2.5–25 mm²
Stranded conductor range 2.5–16 mm²
Standards IEC 61643-11 / EN 61643-11
Mounting DIN rail
Dimensions (H × W × D) 95 × 53.4 × 58 mm
Net weight approx. 0.36 kg

Frequently Asked Questions

What is the ABB OVR T2 3L 40-275 P TS QS used for?

The ABB OVR T2 3L 40-275 P TS QS is a three-pole Type 2 surge protective device designed to protect 230/400 V AC TN-C electrical installations and connected equipment against transient overvoltages.

What is the maximum discharge current of the ABB OVR T2 3L 40-275 P TS QS?

The device has a maximum discharge current (Imax) of 40 kA and a nominal discharge current (In) of 20 kA, using an 8/20 µs surge current waveform.

What voltage is the ABB 2CTB803873R2500 designed for?

The OVR T2 3L 40-275 P TS QS is designed for 230/400 V AC three-phase TN-C networks and has a maximum continuous operating voltage (Uc) of 275 V AC.

Does the ABB OVR T2 3L 40-275 P TS QS have remote signalling?

Yes. The TS version includes an auxiliary signalling contact for remote monitoring of the surge protective device's status, in addition to local mechanical status indication.

Does the ABB OVR T2 3L 40-275 P TS QS use replaceable protection modules?

Yes. The device uses pluggable, replaceable protection modules, allowing the protection elements to be serviced while retaining the installed SPD base and associated wiring.

Trusted Surge Protection from ABB

ABB OVR Type 2 surge protective devices combine high surge-current handling, pluggable construction, QuickSafe technology and remote signalling options to provide practical protection and condition monitoring for three-phase low-voltage electrical installations.