Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 2CTB803873R1200 OVR T2-T3 N3 20-275 P QS is a 3P+N pluggable QuickSafe Type 2 and Type 3 surge protective device for 230/400 V AC TT and TN-S networks with 20 kA maximum discharge current and replaceable protection cartridges.
£220.78
The ABB OVR T2-T3 N3 20-275 P QS 2CTB803873R1200 is a combined Type 2 and Type 3 surge protective device (SPD) designed for three-phase low-voltage electrical installations. Part of ABB's OVR QuickSafe range, its 3P+N configuration provides coordinated surge protection for TT and TN-S networks, helping protect distribution systems and sensitive downstream equipment against transient overvoltages.
Designed for 230/400 V AC systems, the OVR T2-T3 N3 20-275 P QS has a maximum continuous operating voltage Uc of 275 V AC. It provides a maximum discharge current Imax of 20 kA and a nominal discharge current In of 5 kA using an 8/20 µs waveform, together with a combination-wave open-circuit voltage Uoc of 6 kV.
ABB's QuickSafe (QS) technology combines pluggable construction with replaceable phase and neutral cartridges for straightforward servicing. The device provides an L-N voltage protection level Up of 0.9 kV and an N-PE protection level of 1.4 kV, while mechanical status indication allows the condition of each protection element to be checked locally.
Combined Type 2 and Type 3 SPDs provide distribution-level surge-current handling together with enhanced voltage limitation for sensitive downstream equipment. In three-phase TT and TN-S installations, the 3P+N configuration provides coordinated protection between the phase conductors, neutral and protective earth, helping reduce potentially damaging transient voltages throughout the installation.
The ABB OVR T2-T3 N3 20-275 P QS combines 20 kA Imax, 5 kA In and a 0.9 kV L-N Up with ABB QuickSafe technology. Replaceable phase and neutral cartridges, mechanical status indication and a compact DIN-rail format support efficient inspection and maintenance throughout the SPD's service life.
Tick the specs you need, then view products that match.
| Remote Signal | No | |
|---|---|---|
| Device Type | Surge protection device | |
| SPD Type | Type 2+3 | |
| Impulse Current Iimp (kA) | 2 kA | |
| Series | OVR T2-T3 QuickSafe | |
| Order code | 2CTB803873R1200 | |
| EAN | 3660308520012 | |
| Product group | Surge Protection Devices | |
| Product type | Combined Type 2 + Type 3 surge protective device | |
| Arrester class | II + III | |
| Number of protected poles | 4 (3P+N) | |
| Compatible distribution systems | TT / TN-S | |
| Nominal AC system voltage | 230/400 V AC | |
| Rated voltage | 400 V AC | |
| Maximum continuous operating voltage Uc | 275 V AC | |
| DC voltage rating | 350 V DC | |
| Frequency | 47–63 Hz | |
| Maximum discharge current Imax (8/20 µs) | 20 kA | |
| Nominal discharge current In (8/20 µs) | 5 kA | |
| Impulse current Iimp (10/350 µs) | 2 kA | |
| Combination-wave open-circuit voltage Uoc | 6 kV | |
| Voltage protection level Up (L-N) | 0.9 kV | |
| Voltage protection level Up (N-PE) | 1.4 kV | |
| Overall voltage protection level | 1.4 kV | |
| Short-circuit withstand rating | 100 kA | |
| Total discharge current | 80 kA | |
| Ground residual current | <10 µA | |
| Response time | <25 ns | |
| Construction | Pluggable | |
| Technology | QuickSafe (QS) | |
| Status indication | Mechanical indicator for each arrester | |
| Phase replacement cartridge | OVR T2-T3 20-275 C QS, 2CTB803876R1200 | |
| Neutral replacement cartridge | OVR T2 N 80-275 C QS, 2CTB803876R0000 | |
| Maximum backup protection | 125 A circuit breaker or gG/gL fuse | |
| Solid conductor range | 2.5–25 mm² | |
| Stranded conductor range | 2.5–16 mm² | |
| Degree of protection | IP20 | |
| Operating temperature | −40 to +80 °C | |
| Maximum altitude | 2000 m | |
| Fire resistance | UL 94 V-0 | |
| Dimensions (H × W × D) | 88 × 71.2 × 58 mm | |
| Weight | 480 g | |
| Standards | IEC 61643-11 / EN 61643-11 |
The ABB 2CTB803873R1200 is a 3P+N combined Type 2 and Type 3 surge protective device with QuickSafe pluggable construction, designed for 230/400 V AC TT and TN-S three-phase networks.
The device has a maximum discharge current Imax of 20 kA and a nominal discharge current In of 5 kA, based on an 8/20 µs waveform.
The ABB 2CTB803873R1200 provides a voltage protection level Up of 0.9 kV between line and neutral and 1.4 kV between neutral and protective earth.
Yes. The QuickSafe design is pluggable. The phase positions use the OVR T2-T3 20-275 C QS cartridge, order code 2CTB803876R1200, while the neutral position uses the OVR T2 N 80-275 C QS, order code 2CTB803876R0000.
The device is designed for compatible 230/400 V AC TT and TN-S three-phase systems and provides four-pole 3P+N surge protection.
ABB OVR QuickSafe surge protective devices provide electrical designers, installers and maintenance professionals with coordinated protection against transient overvoltages, combining replaceable pluggable cartridges, clear status indication and robust surge-current performance for three-phase distribution systems.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.