1TVS151800S3612 ABB EPX-6303-E2-MCCB 630A 3-Pole Electronic LSI MCCB XT5 Protecta Power

1TVS151800S3612 ABB EPX-6303-E2-MCCB 630A 3-Pole Electronic LSI MCCB XT5 Protecta Power

ABB EPX-6303-E2-MCCB (1TVS151800S3612) is a 630 A three-pole electronic LSI moulded-case circuit breaker based on the ABB Tmax XT5 platform, providing long-time, short-time and instantaneous protection for compatible Protecta Power electrical distribution assemblies.

SKU: 1TVS151800S3612Alt SKU: EPX-6303-E2-MCCBMPN: 1TVS151800S3612
Price
List Price £2,275.03 ex VAT
Your Price (ex VAT)
£2,275.03
Manufacturer Lead Time Estimated Delivery 3 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,275.03
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,275.03

Why Choose the ABB EPX-6303-E2-MCCB 630A 3-Pole Electronic LSI MCCB?

The ABB EPX-6303-E2-MCCB, manufacturer order code 1TVS151800S3612, is a 630 A three-pole electronic LSI moulded-case circuit breaker (MCCB) based on the ABB Tmax XT5 platform. Part of the ABB Protecta Power Enclosures product group, it is designed for professional low-voltage electrical distribution applications requiring electronic overload and short-circuit protection.

Officially described as the 630A 3P Electronic LSI MCCB - XT5, this protective device combines a 630 A current rating, three-pole construction and electronic LSI trip functionality. LSI stands for long-time, short-time and instantaneous protection, providing three distinct protective characteristics for electrical circuit protection and coordination.

The ABB Tmax XT5 platform supports both thermal-magnetic and electronic trip technologies. With electronic LSI protection, the EPX-6303-E2-MCCB offers configurable protective characteristics within the manufacturer's specified adjustment ranges, making it suitable for electrical distribution designs where overload protection, short-circuit response and coordination with downstream devices must be considered together.

For electrical contractors, panel builders and switchgear manufacturers, the ABB EPX-6303-E2-MCCB provides a manufacturer-designated protective device for compatible ABB Protecta Power assemblies. Its electronic trip functionality makes it particularly relevant to commercial and industrial installations requiring carefully specified incoming or distribution circuit protection.

Key Advantages

  • 630 A rated MCCB for demanding low-voltage electrical distribution applications.
  • Three-pole (3P) configuration for suitable three-phase circuits.
  • Based on the established ABB Tmax XT5 circuit breaker platform.
  • Electronic LSI protection with long-time, short-time and instantaneous functions.
  • Adjustable protective characteristics within the manufacturer's specified limits.
  • Provides automatic overload and short-circuit protection.
  • Supports protection coordination and selectivity studies.
  • Offers an electronic-trip alternative to thermal-magnetic MCCBs.
  • Suitable for compatible ABB Protecta Power electrical distribution assemblies.
  • Dedicated ABB order code 1TVS151800S3612 supports accurate specification and procurement.

Key Features

  • ABB EPX-6303-E2-MCCB electronic-trip moulded-case circuit breaker.
  • 630 A rated current designation.
  • Three-pole (3P) construction.
  • ABB Tmax XT5 device platform.
  • Electronic LSI protection characteristics.
  • L protection: Long-time overload protection.
  • S protection: Short-time delayed short-circuit protection.
  • I protection: Instantaneous short-circuit protection.
  • Electronic trip functionality for coordinated electrical protection design.
  • Automatic circuit interruption under qualifying overload and short-circuit conditions.
  • Manual circuit switching capability.
  • Designed for professional low-voltage distribution applications.
  • Part of the ABB Protecta Power Enclosures product group.
  • Suitable for integration with manufacturer-approved XT5 mounting and connection accessories.
  • Distinct from thermal-magnetic MCCBs and non-automatic switch disconnectors.
  • ABB manufacturer order code 1TVS151800S3612.

Specification note: The exact short-circuit breaking capacity, operational voltage limits, trip adjustment ranges, terminal arrangement and physical dimensions must be confirmed against the ABB documentation for order code 1TVS151800S3612. The 630 A rating does not independently establish the breaker's short-circuit breaking capacity.

Understanding ABB Electronic LSI Circuit Protection

The defining feature of the ABB EPX-6303-E2-MCCB is its electronic LSI protection system. Unlike a conventional thermal-magnetic circuit breaker, an electronic-trip MCCB uses electronic protection technology to monitor current and initiate tripping according to the configured protective characteristics.

The long-time (L) protection function is intended to protect conductors and associated electrical equipment against sustained overload conditions. Long-time protection responds when the current exceeds the configured threshold for the applicable period, helping to prevent excessive heating caused by prolonged overloads.

The short-time (S) protection function provides delayed short-circuit protection. This function is particularly relevant where multiple protective devices are installed in series and the electrical designer needs to consider how the upstream and downstream breakers respond to fault conditions.

The instantaneous (I) protection function responds rapidly to qualifying high-current short circuits. Its purpose is to provide prompt interruption when the fault current reaches the applicable instantaneous operating threshold.

ABB's Protecta Power documentation distinguishes Ekip LSI from Ekip LS/I arrangements. With LSI protection, the long-time, short-time and instantaneous characteristics are included for adjustability. This distinction matters when selecting a circuit breaker for an installation requiring specific protective coordination.

The actual settings must be determined through an appropriate electrical protection study. The presence of LSI functionality does not automatically guarantee discrimination or selectivity between protective devices; this must be checked using the relevant ABB coordination data and the completed system design.

ABB Tmax XT5 Platform for 630A Electrical Distribution

The ABB Tmax XT5 platform is part of ABB's moulded-case circuit breaker range for low-voltage power distribution. The XT5 family supports applications up to 630 A and includes both thermal-magnetic and electronic trip technologies, allowing electrical designers to select equipment according to the required protective characteristics.

The EPX-6303-E2-MCCB is specifically identified as a 630 A three-pole electronic LSI MCCB. Its three-pole construction is intended for suitable three-phase electrical circuits requiring protection of three phase conductors.

When specifying an MCCB, the rated current is only one part of the selection process. The electrical designer must also consider the prospective fault current, rated breaking capacity, operational voltage, conductor sizing, installation environment and protective coordination.

The ABB Tmax XT5 family includes different breaking-capacity classifications and trip unit variants. The precise device configuration supplied under the EPX-6303-E2-MCCB order code must therefore be verified before specifying a particular breaking capacity or assuming compatibility with an accessory intended for another XT5 variant.

ABB also offers thermal-magnetic and other electronic-trip MCCBs within the Protecta Power range. The appropriate device should be selected according to the electrical installation's protection requirements rather than assuming that all 630 A XT5 circuit breakers provide identical trip functionality.

Integration with ABB Protecta Power Panelboards

The ABB Protecta Power system provides a modular approach to commercial and industrial low-voltage distribution. The product family includes panelboard enclosures, incoming devices, outgoing protective devices, metering accessories and connection components.

The EPX-6303-E2-MCCB belongs to this product family and is intended for compatible distribution arrangements requiring a 630 A three-pole electronic LSI circuit breaker. The exact approved panelboard models and mounting arrangements must be checked against the current ABB selection guide and installation instructions.

Where the MCCB is used as an incoming protective device, the designer must verify the panelboard's busbar rating, the incoming conductor arrangement, the required connection accessories and the relationship between the incoming and outgoing protective devices.

For installations with large incoming or outgoing cables, adequate termination space and appropriate cable management are important. ABB's Protecta Power literature advises considering a side cableway extension box for larger cables when using XT5 outgoing devices. The need for such an extension depends on the final assembly arrangement.

Only manufacturer-approved mounting, connection and protective accessories should be used. Compatibility with the selected XT5 device must be confirmed before installation, particularly where alternative terminal arrangements or larger conductors are required.

The EPX-6303-E2-MCCB is a protective circuit breaker, not a complete panelboard. The enclosure, electrical connection components, mounting accessories and any additional devices must be specified separately unless their inclusion is explicitly confirmed by the supplier.

Typical Applications

  • Compatible ABB Protecta Power low-voltage distribution assemblies.
  • 630 A three-phase circuit protection.
  • Commercial building electrical distribution.
  • Industrial MCCB distribution panelboards.
  • Main and sub-distribution systems requiring electronic LSI protection.
  • Electrical installations requiring adjustable overload and short-circuit protection.
  • Distribution systems with coordinated upstream and downstream protective devices.
  • Electrical plant rooms and switchgear installations.
  • Large office buildings and commercial developments.
  • Retail centres and mixed-use properties.
  • Warehouses and logistics facilities.
  • Manufacturing plants and industrial premises.
  • Infrastructure electrical distribution projects.
  • Professional switchgear manufacturing and electrical panel building.

Technical Specifications

Product group Protecta Power Enclosures
Product series ABB Protecta Power
ABB order code 1TVS151800S3612
Manufacturer description 630A 3P Electronic LSI MCCB - XT5
Product type Moulded-case circuit breaker (MCCB)
Device category Electronic-trip protective circuit breaker
Rated current designation 630 A
Number of poles 3
Pole configuration Three-pole (3P)
Device platform ABB Tmax XT5
Trip technology Electronic
Protection characteristic LSI
Long-time protection (L) Overload protection
Short-time protection (S) Delayed short-circuit protection
Instantaneous protection (I) Instantaneous short-circuit protection
Protective settings Adjustable within manufacturer-specified limits
Primary functions Automatic circuit protection and switching
Compatible product family ABB Protecta Power
Application Low-voltage three-phase electrical distribution
Installation requirement Selection, installation and protection coordination in accordance with ABB documentation and applicable electrical standards

Frequently Asked Questions

What is the ABB EPX-6303-E2-MCCB used for?

The ABB EPX-6303-E2-MCCB is a 630 A three-pole electronic LSI moulded-case circuit breaker based on the ABB Tmax XT5 platform. It is intended for compatible low-voltage distribution assemblies requiring automatic overload and short-circuit protection with electronic trip characteristics.

What does LSI mean on the ABB EPX-6303-E2-MCCB?

LSI stands for Long-time, Short-time and Instantaneous protection. Long-time protection responds to overload conditions, short-time protection provides delayed short-circuit protection, and instantaneous protection responds rapidly to qualifying high-current short circuits.

What is the difference between an electronic LSI MCCB and a thermal-magnetic MCCB?

An electronic LSI MCCB uses electronic trip technology with long-time, short-time and instantaneous protection characteristics. A thermal-magnetic MCCB uses thermal and magnetic elements for overload and short-circuit protection. The appropriate device depends on the installation's protection settings, coordination requirements and electrical design.

Is the ABB EPX-6303-E2-MCCB a three-pole or four-pole circuit breaker?

The EPX-6303-E2-MCCB is a three-pole (3P) circuit breaker with a 630 A current rating. It is intended for suitable three-phase electrical circuits requiring three protected poles. Where four-pole protection is required, a separately specified compatible four-pole device must be selected.

Does the ABB EPX-6303-E2-MCCB include a complete Protecta Power panelboard?

No. The EPX-6303-E2-MCCB is an electronic-trip moulded-case circuit breaker, not a complete electrical distribution panelboard. The compatible enclosure, mounting components, connection accessories and other required assembly parts must be selected according to ABB's approved installation arrangements.

ABB Electronic Circuit Protection for Professional Panel Builders

The ABB EPX-6303-E2-MCCB 630 A Three-Pole Electronic LSI MCCB, order code 1TVS151800S3612, combines the ABB Tmax XT5 platform with long-time, short-time and instantaneous electronic protection. Designed for compatible Protecta Power distribution assemblies, it supports professional low-voltage circuit protection design where overload protection, short-circuit response and protective coordination are essential.