ABB EPX-4004-E1-MCCB 1TVS151800S3371 is a 400 A four-pole Tmax XT5 electronic moulded case circuit breaker with Ekip LS/I protection for incoming circuits in compatible ABB Protecta Power distribution panelboards.

SKU: 1TVS151800S3371Alt SKU: EPX-4004-E1-MCCBMPN: 1TVS151800S3371
Price
List Price £1,930.30 ex VAT
Your Price (ex VAT)
£1,930.30
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,930.30
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,930.30

Why Choose the ABB EPX-4004-E1-MCCB 400A 4-Pole Electronic MCCB?

The ABB EPX-4004-E1-MCCB, manufacturer order code 1TVS151800S3371, is a 400 A, four-pole electronic moulded case circuit breaker (MCCB) from the ABB Tmax XT5 family, specified as an incoming protective device for compatible ABB Protecta Power low-voltage distribution panelboards.

Featuring an ABB Ekip LS/I electronic trip unit, the EPX-4004-E1-MCCB provides overload protection and selectable short-circuit protection characteristics. Its four-pole configuration is intended for distribution arrangements requiring a four-pole incoming circuit breaker, subject to the applicable neutral protection and switching requirements.

Designed for integration into the Protecta Power system, this MCCB provides a manufacturer-designated incoming protection solution for commercial and industrial distribution installations. The product is part of ABB's coordinated range of incoming devices, connection kits and panelboard accessories, helping electrical contractors and switchboard builders specify compatible equipment for their distribution assemblies.

Key Advantages

  • 400 A rated current for substantial low-voltage incoming distribution applications.
  • Four-pole configuration for compatible three-phase, four-wire electrical systems.
  • ABB Tmax XT5 MCCB platform designed for professional power distribution.
  • Ekip LS/I electronic trip protection for configurable overload and short-circuit protection.
  • Provides an incoming circuit protection solution for compatible ABB Protecta Power panelboards.
  • Electronic trip technology supports more flexible protection settings than conventional fixed thermal-magnetic arrangements.
  • Part of ABB's coordinated incoming MCCB range.
  • Suitable for commercial and industrial low-voltage electrical distribution systems.
  • Supports protection coordination when correctly selected and configured.
  • Manufacturer-designated solution for professional switchboard construction and electrical installation.

Key Features

  • ABB Protecta Power electronic incoming MCCB.
  • EPX-4004-E1-MCCB model designation.
  • Manufacturer order code 1TVS151800S3371.
  • 400 A rated current.
  • Four-pole (4P) circuit breaker configuration.
  • ABB Tmax XT5 circuit breaker family.
  • Electronic trip unit: ABB Ekip LS/I.
  • L protection: Overload protection.
  • S protection: Short-circuit protection with delayed tripping, selectable within the LS/I arrangement.
  • I protection: Instantaneous short-circuit protection, selectable within the LS/I arrangement.
  • Designed for use as an incoming MCCB in compatible ABB Protecta Power panelboards.
  • Manufacturer-listed maximum XT5 cable capacity of 185 mm², subject to the applicable terminal and conductor arrangement.
  • Part of the ABB Protecta Power incoming device selection range.
  • Suitable for installation by qualified electrical professionals.

Ekip LS/I Electronic Protection for 400A Incoming Distribution Circuits

The ABB EPX-4004-E1-MCCB combines the Tmax XT5 circuit breaker platform with electronic trip protection for incoming distribution applications. Electronic protection enables settings to be selected according to the circuit characteristics and the coordination requirements of the electrical installation.

The standard Ekip LS/I trip arrangement provides L overload protection together with a choice between S short-circuit protection with delayed tripping and I instantaneous short-circuit protection. This differs from an Ekip LSI arrangement, in which all three L, S and I characteristics are available together for adjustment. Protection settings must be established through the electrical design and commissioning process.

The four-pole XT5 configuration is intended for suitable incoming arrangements in which four-pole switching or protection is required. The precise neutral-pole protection behaviour must be confirmed from the fitted circuit breaker and trip unit documentation rather than assumed solely from the 4P designation.

Integration with ABB Protecta Power Panelboards

ABB lists the EPX-4004-E1-MCCB as a 400 A, four-pole electronic XT5 incoming MCCB in its Protecta Power selection guide. The incoming device range also includes thermal-magnetic XT5 alternatives and three-pole electronic variants, enabling designers to select the appropriate protective technology and pole arrangement.

The associated EPX-4004CK is the manufacturer-designated 400 A XT5 four-pole incoming connection kit. ABB identifies incomer support brackets, shrouding and busbar connectivity within its incoming connection kit arrangements. The required connection kit and other installation components should be selected separately according to the complete panelboard configuration.

ABB lists a maximum XT5 cable capacity of 185 mm² in its Protecta Power incoming device guidance. Actual conductor compatibility depends on the fitted terminals, conductor material, cable preparation and installation requirements. Front extended terminals are also identified by ABB as an available option for suitable lug connections.

The specific breaking capacity, rated operational voltage and detailed trip adjustment ranges of the supplied EPX-4004-E1-MCCB should be verified against its exact ABB circuit breaker configuration before final specification. These values are not determined solely by the XT5 frame size and 400 A rating.

Typical Applications

  • ABB Protecta Power 400 A incoming MCCB installations.
  • Commercial building main and sub-main electrical distribution.
  • Industrial low-voltage switchboards and panelboards.
  • Three-phase electrical distribution systems requiring four-pole incoming protection.
  • Electrical plant rooms and power distribution infrastructure.
  • Building services distribution installations.
  • Commercial facilities requiring electronic overcurrent protection.
  • Electrical panel manufacturing and switchboard assembly.
  • Distribution systems requiring coordinated overload and short-circuit protection.
  • Compatible ABB Protecta Power panelboard upgrades and refurbishment projects.

Technical Specifications

Product family Protecta Power Enclosures
Circuit breaker series ABB Tmax XT5
ABB order code 1TVS151800S3371
Manufacturer description EPX-4004-E1-MCCB 400A 4P Elec MCCB - XT5
Product type Electronic moulded case circuit breaker (MCCB)
Rated current 400 A
Number of poles 4
Pole configuration Four-pole (4P)
Trip technology Electronic
Trip unit family ABB Ekip
Standard trip protection LS/I
Overload protection L
Short-circuit protection S or I selection
Associated incoming connection kit EPX-4004CK, 400 A XT5 four-pole connection kit
Manufacturer-listed maximum XT5 cable capacity 185 mm², dependent on terminal configuration
Installation position Incoming circuit breaker
Compatible distribution system ABB Protecta Power
Primary function Incoming circuit switching and overcurrent protection
Application Low-voltage electrical distribution panelboards
Manufacturer product group Protecta Power Enclosures

Frequently Asked Questions

What is the ABB EPX-4004-E1-MCCB used for?

The ABB EPX-4004-E1-MCCB is a 400 A, four-pole electronic Tmax XT5 MCCB designed for use as an incoming circuit breaker in compatible ABB Protecta Power electrical distribution panelboards.

What electronic trip protection does the EPX-4004-E1-MCCB provide?

The EPX-4004-E1-MCCB is specified with ABB Ekip LS/I electronic protection, providing overload protection (L) and selectable delayed short-circuit (S) or instantaneous short-circuit (I) protection characteristics.

What is the current rating and pole configuration of the ABB EPX-4004-E1-MCCB?

The circuit breaker has a specified current rating of 400 A and a four-pole (4P) configuration. It belongs to the ABB Tmax XT5 moulded case circuit breaker family.

Which incoming connection kit is associated with the EPX-4004-E1-MCCB?

ABB lists the EPX-4004CK as the 400 A XT5 four-pole incoming connection kit for the Protecta Power system. The required kit and installation accessories should be confirmed against the complete panelboard configuration.

What is the difference between the ABB EPX-4004MCCB and EPX-4004-E1-MCCB?

Both are 400 A, four-pole ABB Tmax XT5 incoming MCCBs. The EPX-4004MCCB is the thermal-magnetic version, while the EPX-4004-E1-MCCB uses an electronic Ekip LS/I trip unit. The appropriate version depends on the required protection characteristics and electrical system design.

Trusted ABB Circuit Protection and Power Distribution Solutions

ABB Tmax XT circuit breakers and Protecta Power distribution systems provide coordinated solutions for professional low-voltage electrical installations. The ABB EPX-4004-E1-MCCB combines a 400 A four-pole XT5 circuit breaker with Ekip LS/I electronic protection, supporting dependable incoming circuit protection in compatible commercial and industrial distribution panelboards.