1SDX255187R1 ABB EPX-XT4S-E2-1604 160A 4-Pole 50kA MCCB LSI

1SDX255187R1 ABB EPX-XT4S-E2-1604 160A 4-Pole 50kA MCCB LSI

ABB EPX-XT4S-E2-1604 is a 160 A four-pole Tmax XT4S moulded case circuit breaker with 50 kA short-circuit breaking capacity at 415 V AC and Ekip LSI electronic protection for industrial and commercial low-voltage electrical distribution systems.

SKU: 1SDX255187R1Alt SKU: EPX-XT4S-E2-1604MPN: 1SDX255187R1
Price
List Price £2,153.32 ex VAT
Your Price (ex VAT)
£2,153.32
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,153.32
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,153.32

Why Choose the ABB EPX-XT4S-E2-1604 160A 4-Pole 50kA MCCB?

The ABB EPX-XT4S-E2-1604 is a high-performance 160 A four-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in industrial and commercial low-voltage electrical distribution systems. As part of the ABB Protecta Power Devices range, incorporating the ABB Tmax XT4S160 circuit breaker platform, it delivers dependable electrical protection for distribution boards, switchgear assemblies and three-phase power distribution installations.

This circuit breaker features an ABB Ekip LSI electronic trip unit, providing long-time overload protection, short-time delayed short-circuit protection and instantaneous short-circuit protection. These three protection functions offer flexibility when coordinating protective devices within electrical distribution networks. The electronic trip technology supports accurate overcurrent detection and dependable fault interruption, helping safeguard electrical cables, switchgear and connected equipment.

With a 160 A rated current, four-pole configuration and 50 kA short-circuit breaking capacity at 415 V AC, the EPX-XT4S-E2-1604 is suitable for demanding low-voltage distribution applications requiring reliable circuit protection and neutral-pole switching. Its compact 140 mm four-pole XT4S format enables efficient integration into electrical distribution panels, industrial switchboards and suitable ABB Protecta Power assemblies.

Key Advantages

  • Reliable 160 A moulded case circuit breaker for industrial and commercial electrical distribution.
  • Four-pole (4P) configuration suitable for three-phase systems requiring neutral-pole switching.
  • 50 kA short-circuit breaking capacity at 415 V AC for demanding low-voltage electrical installations.
  • ABB Ekip LSI electronic protection incorporating long-time, short-time and instantaneous trip functions.
  • Adjustable electronic protection characteristics support effective circuit protection coordination.
  • Short-time delayed protection can help improve discrimination between upstream and downstream protective devices.
  • Compact ABB Tmax XT4S160 breaker platform for efficient switchboard integration.
  • Suitable for integration into ABB Protecta Power distribution assemblies.
  • Helps protect electrical infrastructure and connected equipment against damaging overload and short-circuit conditions.

Key Features

  • ABB Protecta Power Devices range.
  • ABB Tmax XT4S160 moulded case circuit breaker platform.
  • 160 A rated current.
  • Four-pole (4P) configuration.
  • 50 kA rated ultimate short-circuit breaking capacity at 415 V AC.
  • ABB Ekip LSI electronic trip unit.
  • Long-time overload protection (L).
  • Short-time delayed short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Electronic protection settings for application-specific circuit protection requirements.
  • 690 V AC maximum rated operational voltage for the XT4S160 platform.
  • 50/60 Hz rated frequency.
  • Automatic circuit interruption under applicable overload and short-circuit fault conditions.
  • Compact 140 mm four-pole breaker width.
  • Manual switching mechanism with automatic protective tripping.
  • Suitable for low-voltage distribution boards and industrial switchgear assemblies.
  • ABB manufacturer order code 1SDX255187R1.

Reliable Four-Pole Electronic Circuit Protection for Electrical Distribution Systems

Moulded case circuit breakers such as the ABB EPX-XT4S-E2-1604 are essential components in modern low-voltage electrical distribution systems. They protect electrical circuits against excessive current caused by overloads and short circuits, automatically interrupting the electrical supply when fault conditions exceed the configured protection thresholds. This helps safeguard electrical cables, switchgear and connected equipment while supporting reliable electrical system operation.

The ABB Tmax XT4S160 platform combines compact construction with advanced electronic circuit protection technology for demanding industrial and commercial installations. Its Ekip LSI trip unit incorporates long-time overload protection, short-time delayed short-circuit protection and instantaneous short-circuit protection. These functions provide flexibility when designing coordinated electrical protection systems. The four-pole arrangement supports three-phase distribution systems where neutral-pole switching is required, subject to the electrical installation design and applicable standards.

Typical Applications

  • Industrial low-voltage electrical distribution boards.
  • Commercial building power distribution systems.
  • Three-phase and neutral electrical feeder circuits.
  • ABB Protecta Power distribution assemblies.
  • Main and sub-distribution switchboards.
  • Industrial machinery supply circuit protection.
  • Manufacturing facilities and production plants.
  • Building services and electrical infrastructure.
  • Electrical control panels and automation installations.
  • OEM electrical equipment and panel-building applications.

Technical Specifications

Product range Protecta Power Devices
Series Tmax XT
Breaker platform XT4S160
ABB order code 1SDX255187R1
Product type Moulded case circuit breaker (MCCB)
Rated current 160 A
Frame rated current 160 A
Number of poles 4P (four-pole)
Rated ultimate short-circuit breaking capacity (Icu) 50 kA at 415 V AC
Rated service short-circuit breaking capacity (Ics) 50 kA at 415 V AC
Rated operational voltage (Ue) Up to 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 8 kV
Rated frequency 50/60 Hz
Trip unit technology Electronic
Trip unit ABB Ekip LSI
Overload protection Long-time protection (L)
Short-time protection Delayed short-circuit protection (S)
Instantaneous protection Instantaneous short-circuit protection (I)
Short-circuit performance level S
Breaker construction Moulded case
Operating mechanism Manual switching with automatic protective tripping
Width 140 mm
Applicable standard IEC 60947-2
Application Low-voltage electrical distribution and circuit protection
Installation Electrical distribution boards and switchgear assemblies

Frequently Asked Questions

What is the ABB EPX-XT4S-E2-1604 used for?

The ABB EPX-XT4S-E2-1604 is a four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits in industrial and commercial installations.

What is the rated current of the EPX-XT4S-E2-1604?

The circuit breaker has a 160 A rated current and uses the ABB Tmax XT4S160 breaker platform, making it suitable for appropriately designed low-voltage electrical distribution circuits requiring 160 A protection.

What is the short-circuit breaking capacity of this MCCB?

The EPX-XT4S-E2-1604 has a 50 kA rated ultimate short-circuit breaking capacity at 415 V AC, providing high fault-current interruption capability for suitable low-voltage electrical distribution applications.

What does Ekip LSI electronic protection mean?

ABB Ekip LSI electronic protection incorporates long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). All three functions are included, providing flexibility for circuit protection settings and electrical system coordination.

Where is the ABB EPX-XT4S-E2-1604 typically installed?

This four-pole MCCB is typically installed in electrical distribution boards, industrial switchboards and low-voltage switchgear assemblies, including suitable ABB Protecta Power distribution systems requiring three-phase circuit protection and neutral-pole switching.

Trusted by Electrical Engineers and Industrial Panel Builders Worldwide

ABB Tmax XT moulded case circuit breakers are widely used by electrical engineers, switchgear manufacturers and industrial panel builders to provide dependable overload and short-circuit protection in modern power distribution systems. The ABB EPX-XT4S-E2-1604 combines a 160 A current rating, four-pole construction, 50 kA breaking capacity and Ekip LSI electronic protection in a compact circuit breaker designed for reliable industrial and commercial electrical distribution.