1SDX255182R1 ABB EPX-XT4S-E2-1603 160A 3-Pole 50kA Electronic LSI MCCB

1SDX255182R1 ABB EPX-XT4S-E2-1603 160A 3-Pole 50kA Electronic LSI MCCB

ABB EPX-XT4S-E2-1603 is a 160 A three-pole moulded case circuit breaker with 50 kA breaking capacity and an Ekip Dip electronic LSI trip unit, designed for configurable overload, short-time and instantaneous short-circuit protection in low-voltage electrical distribution systems.

SKU: 1SDX255182R1Alt SKU: EPX-XT4S-E2-1603MPN: 1SDX255182R1
Price
List Price £1,694.42 ex VAT
Your Price (ex VAT)
£1,694.42
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,694.42
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,694.42

Why Choose the ABB EPX-XT4S-E2-1603 160A 3-Pole 50kA MCCB?

The ABB EPX-XT4S-E2-1603 is a high-performance 160 A, 3-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. Featuring a 50 kA breaking capacity and an Ekip Dip electronic LSI trip unit, this circuit breaker offers configurable protection for commercial, industrial and infrastructure electrical installations.

As part of the ABB Protecta Power Devices range, the EPX-XT4S-E2-1603 incorporates proven ABB SACE Tmax XT4S160 circuit breaker technology. Its electronic protection system combines long-time overload protection, short-time delayed short-circuit protection and instantaneous short-circuit protection, helping safeguard electrical cables, distribution equipment and connected installations against damaging electrical faults.

With a 160 A rated current, three-pole configuration and 50 kA short-circuit breaking capacity, the EPX-XT4S-E2-1603 is suitable for three-phase electrical distribution circuits requiring advanced electronic protection. Its compact XT4S160 construction supports integration into ABB Protecta Power distribution boards, electrical switchboards and compatible low-voltage switchgear assemblies.

Key Advantages

  • 160 A rated current suitable for commercial and industrial low-voltage distribution circuits.
  • 50 kA breaking capacity provides protection against high prospective short-circuit currents at the applicable rated voltage.
  • Three-pole construction supports coordinated protection and switching of three-phase electrical circuits.
  • Ekip Dip electronic LSI trip unit provides configurable overload and short-circuit protection.
  • Long-time (L) protection helps protect conductors and connected equipment against sustained overload conditions.
  • Short-time (S) protection provides delayed short-circuit tripping to support protective device coordination.
  • Instantaneous (I) protection provides rapid tripping during high-current short-circuit faults.
  • Electronic trip technology supports flexible protection settings and electrical distribution selectivity.
  • ABB SACE Tmax XT4S160 technology combines electronic protection with robust moulded case construction.
  • Suitable for integration into ABB Protecta Power distribution systems and compatible low-voltage switchgear.

Key Features

  • ABB Protecta Power Devices electronic trip moulded case circuit breaker.
  • SACE Tmax XT4S160 circuit breaker platform.
  • 160 A rated current for low-voltage electrical distribution protection.
  • 50 kA short-circuit breaking capacity at the applicable rated voltage.
  • Three-pole configuration for three-phase electrical distribution systems.
  • Ekip Dip LSI electronic trip unit providing long-time, short-time and instantaneous protection.
  • L protection: Long-time overload protection for sustained overcurrent conditions.
  • S protection: Short-time delayed short-circuit protection.
  • I protection: Instantaneous short-circuit protection.
  • Configurable electronic protection settings support coordination with upstream and downstream circuit breakers.
  • 160 A frame rating within the ABB Tmax XT4S family.
  • Fixed mounting configuration with front terminals on the corresponding XT4S160 Ekip LSI breaker.
  • Mechanical operating mechanism with manual switching and automatic protective tripping.
  • Based on circuit breaker technology designed in accordance with IEC 60947-2.

Advanced Electronic LSI Circuit Protection

The ABB EPX-XT4S-E2-1603 uses an Ekip Dip electronic trip unit to monitor electrical current and initiate protective tripping when overload or short-circuit conditions occur. Its LSI protection functionality combines long-time overload protection with short-time delayed and instantaneous short-circuit protection. This arrangement allows protection settings to be coordinated with the electrical installation, helping reduce the effects of electrical faults and supporting continuity of supply where selective protection is achieved.

The ABB SACE Tmax XT4S160 platform combines electronic protection technology with a robust mechanical switching system. Its three-pole construction provides coordinated protection for three-phase electrical circuits, while the 160 A current rating and 50 kA breaking capacity make it suitable for appropriately designed commercial and industrial distribution installations. Compared with LS/I protection, the LSI configuration provides separate long-time, short-time and instantaneous protection functions for additional flexibility in electrical system coordination.

Typical Applications

  • Commercial and industrial low-voltage distribution boards.
  • ABB Protecta Power electrical distribution assemblies.
  • Three-phase electrical distribution and feeder circuits.
  • Industrial machinery and equipment supply circuits.
  • Electrical switchboards and industrial control panels.
  • Building services and infrastructure power distribution.
  • Manufacturing facilities and industrial electrical installations.
  • Sub-distribution circuits requiring electronic LSI protection.
  • Electrical distribution systems requiring coordinated long-time, short-time and instantaneous protection.

Technical Specifications

Product range Protecta Power Devices
Series SACE Tmax XT4S
Frame designation XT4S160
ABB order code 1SDX255182R1
Product type Electronic trip moulded case circuit breaker (MCCB)
Rated current 160 A
Number of poles 3
Breaking capacity 50 kA
Trip unit type Ekip Dip electronic LSI
Overload protection L – long-time protection
Short-time protection S – delayed short-circuit protection
Instantaneous protection I – instantaneous short-circuit protection
Trip technology Electronic
Frame rated current 160 A
Rated operational voltage Up to 690 V AC for the XT4S platform
Rated insulation voltage (Ui) 1000 V for the XT4S platform
Rated impulse withstand voltage (Uimp) 8 kV for the XT4S platform
Electrical system Three-phase AC distribution
Operating mechanism Mechanical toggle operation
Application Low-voltage electrical distribution
Applicable standard IEC 60947-2
Product group Protecta Power Devices

Frequently Asked Questions

What is the ABB EPX-XT4S-E2-1603 used for?

The ABB EPX-XT4S-E2-1603 is a three-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits using an Ekip Dip electronic LSI trip unit.

What is the rated current of the EPX-XT4S-E2-1603?

The circuit breaker has a 160 A rated current and belongs to the ABB SACE Tmax XT4S160 frame family, which has a frame current rating of 160 A.

What is the breaking capacity of this ABB MCCB?

The EPX-XT4S-E2-1603 has a specified 50 kA breaking capacity. The applicable operating voltage, prospective fault current and installation conditions must be considered when selecting the circuit breaker.

What does LSI mean on the ABB EPX-XT4S-E2-1603?

LSI identifies three electronic protection functions: long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). These functions help protect electrical circuits while supporting coordination with other protective devices.

What is the difference between LSI and LS/I trip units?

An LSI trip unit provides long-time, short-time and instantaneous protection functions, allowing separate configuration of the short-circuit protection characteristics. An LS/I trip unit provides long-time overload protection with a choice between short-time delayed or instantaneous short-circuit protection.

Trusted ABB Electronic Circuit Protection Technology

ABB SACE Tmax XT moulded case circuit breakers are engineered to deliver dependable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. The EPX-XT4S-E2-1603 combines a 160 A rated current, three-pole construction, 50 kA breaking capacity and Ekip Dip electronic LSI protection in a robust XT4S160 frame for reliable electrical distribution applications.