1SDX255178R1 ABB EPX-XT2S-E2-1604 160A 4-Pole 50kA Electronic LSI MCCB

1SDX255178R1 ABB EPX-XT2S-E2-1604 160A 4-Pole 50kA Electronic LSI MCCB

ABB EPX-XT2S-E2-1604 is a 160 A four-pole moulded case circuit breaker with 50 kA breaking capacity at 415 V AC, a fully rated neutral and an Ekip DIP electronic LSI trip unit providing long-time overload, short-time delayed and instantaneous short-circuit protection for commercial and industrial low-voltage electrical distribution.

SKU: 1SDX255178R1Alt SKU: EPX-XT2S-E2-1604MPN: 1SDX255178R1
Price
List Price £1,947.17 ex VAT
Your Price (ex VAT)
£1,947.17
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,947.17
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,947.17

Why Choose the ABB EPX-XT2S-E2-1604 160A 4-Pole MCCB?

The ABB EPX-XT2S-E2-1604 is a high-performance 160 A four-pole moulded case circuit breaker (MCCB) designed to deliver reliable overload and short-circuit protection in commercial and industrial electrical distribution systems. Featuring a 50 kA short-circuit breaking capacity and an advanced ABB Ekip DIP LSI electronic trip unit, this circuit breaker provides configurable protection for demanding low-voltage power distribution applications. It belongs to the ABB Protecta Power Devices range and is based on the established ABB SACE Tmax XT2S160 circuit breaker platform.

Unlike conventional thermal-magnetic MCCBs, the EPX-XT2S-E2-1604 incorporates an electronic protection release with three distinct protection functions: long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). These functions allow electrical designers to configure the circuit breaker's response to different fault conditions and support coordination between upstream and downstream protective devices.

With a 160 A rated current, four-pole (4P) configuration and 50 kA breaking capacity, the ABB EPX-XT2S-E2-1604 is suitable for appropriately designed distribution circuits, commercial distribution boards and industrial power systems. Its compact 120 mm four-pole width makes it particularly useful where installation space is limited. The product is identified by ABB order code 1SDX255178R1.

Key Advantages

  • 160 A rated current for reliable protection of appropriately designed commercial and industrial distribution circuits.
  • 50 kA short-circuit breaking capacity provides substantial fault-interruption capability.
  • Four-pole configuration enables simultaneous switching of three phase conductors and neutral.
  • Electronic Ekip DIP LSI protection provides configurable overload and short-circuit protection characteristics.
  • Long-time overload protection (L) helps protect cables and connected equipment against sustained excessive current.
  • Short-time delayed protection (S) supports coordination and discrimination between protective devices.
  • Instantaneous protection (I) provides rapid tripping during severe short-circuit faults.
  • All three LSI protection functions are available, providing greater flexibility than an LS/I release with selectable S or I characteristics.
  • Fully rated neutral supports four-pole electrical distribution applications requiring a neutral rating equal to the phase rating.
  • Based on the established ABB SACE Tmax XT2S160 platform.
  • Compact 120 mm four-pole width supports efficient distribution board integration.
  • Designed for installation within compatible ABB Protecta Power distribution equipment.

Key Features

  • ABB Protecta Power Devices product group.
  • ABB SACE Tmax XT2S160 moulded case circuit breaker platform.
  • 160 A rated current for low-voltage power distribution.
  • 50 kA short-circuit breaking capacity at 415 V AC.
  • Four-pole (4P) construction for three-phase and neutral switching.
  • ABB Ekip DIP LSI electronic trip unit.
  • Long-time (L) protection against sustained overload conditions.
  • Short-time delayed (S) protection for short-circuit protection coordination.
  • Instantaneous (I) protection for rapid operation during high-current faults.
  • Electronic protection technology enables adjustment of protective characteristics.
  • 160 A frame class with a 160 A electronic release.
  • 100% rated neutral in the corresponding four-pole XT2S160 LSI configuration.
  • 120 mm four-pole width for compact panel installation.
  • Fixed-mounted circuit breaker construction with front terminals.
  • Manual operating mechanism with automatic protective tripping.
  • Suitable for compatible ABB Protecta Power electrical distribution assemblies.
  • ABB manufacturer order code: 1SDX255178R1.

Advanced Electronic LSI Protection for Industrial Power Distribution

The ABB EPX-XT2S-E2-1604 uses an advanced electronic trip unit to monitor electrical current and initiate protective tripping when an overload or short-circuit condition exceeds the configured protection thresholds. Electronic protection provides greater flexibility than conventional thermal-magnetic releases and is particularly valuable in electrical distribution systems where accurate protection settings and coordination between protective devices are important.

The long-time (L) protection function responds to sustained overload conditions that may cause excessive heating in electrical cables and connected equipment. The electronic trip unit monitors current over time and initiates tripping when the configured overload characteristic is exceeded. Long-time protection settings should be selected according to cable capacity, connected loads and installation conditions.

The short-time delayed (S) protection function provides short-circuit protection with a configurable delay. This can assist with protective device discrimination by allowing a downstream circuit breaker to clear a fault before an upstream protective device operates. Correctly coordinated short-time protection can help minimise unnecessary disruption to unaffected circuits.

The instantaneous (I) protection function provides rapid tripping when a sufficiently high short-circuit current is detected. This helps limit the duration of severe electrical faults and reduce their potential impact on cables, distribution equipment and connected electrical loads.

A key advantage of the ABB Ekip DIP LSI trip unit is that all three protection characteristics — L, S and I — are included. This differs from an LS/I electronic release, which provides long-time protection with a choice between short-time delayed and instantaneous protection. The LSI configuration offers additional flexibility when designing coordinated electrical protection systems.

The four-pole configuration enables simultaneous switching of three phase conductors and the neutral conductor. The corresponding XT2S160 LSI configuration features a fully rated neutral, providing a neutral current rating equal to the phase current rating. This supports appropriately designed three-phase distribution systems where four-pole switching and full neutral protection are required.

The ABB SACE Tmax XT2S160 platform combines compact construction with advanced electronic protection functionality. With a 160 A rated current, 50 kA breaking capacity at 415 V AC and 120 mm four-pole width, the EPX-XT2S-E2-1604 provides an effective solution for demanding electrical distribution applications where both protection performance and installation space are important.

Typical Applications

  • ABB Protecta Power distribution board installations.
  • Commercial building electrical distribution systems.
  • Three-phase and neutral outgoing circuit protection.
  • Industrial low-voltage electrical distribution panels.
  • Low-voltage switchgear and power distribution assemblies.
  • Commercial offices, retail premises and warehouse installations.
  • Building services and mechanical equipment distribution circuits.
  • Industrial manufacturing and production facilities.
  • Electrical sub-distribution boards and appropriately rated feeder circuits.
  • Power distribution systems requiring high short-circuit interruption capability.
  • Installations requiring electronic long-time, short-time and instantaneous protection.
  • Electrical distribution systems where protective device discrimination is an important design consideration.
  • Three-phase distribution circuits requiring a fully rated neutral.
  • Electrical infrastructure requiring configurable electronic protection characteristics.
  • Distribution board upgrades where electrical and mechanical compatibility has been verified.

Technical Specifications

Product group Protecta Power Devices
Series SACE Tmax XT2S
Circuit breaker platform XT2S160
ABB order code 1SDX255178R1
Corresponding ABB circuit breaker reference 1SDA067850R1
Product type Moulded case circuit breaker (MCCB)
Rated current 160 A
Number of poles 4
Pole configuration Four-pole (3-phase + neutral)
Neutral rating 100% of phase current rating
Ultimate short-circuit breaking capacity (Icu) 50 kA at 415 V AC
Trip unit technology Electronic
Trip unit type ABB Ekip DIP LSI
Long-time protection (L) Electronic overload protection
Short-time protection (S) Electronic delayed short-circuit protection
Instantaneous protection (I) Electronic instantaneous short-circuit protection
Protection configuration LSI — long-time, short-time and instantaneous protection
Frame family XT2S160
Frame current class 160 A
Four-pole device width 120 mm
Rated operational voltage, XT2S platform Up to 690 V AC
Rated insulation voltage (Ui), XT2S platform 1,000 V
Rated impulse withstand voltage (Uimp), XT2S platform 8 kV
Mounting arrangement Fixed installation
Terminal arrangement Front terminals
Operating mechanism Manual lever with automatic protective tripping
Applicable product standard IEC 60947-2
Electrical system Low-voltage AC distribution
Application Commercial and industrial electrical circuit protection
Installation type Compatible electrical distribution boards and switchgear assemblies
Product construction Moulded case circuit breaker

Frequently Asked Questions

What is the ABB EPX-XT2S-E2-1604 used for?

The ABB EPX-XT2S-E2-1604 is a four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It uses an electronic LSI trip unit and is suitable for commercial and industrial installations, including compatible ABB Protecta Power distribution boards.

What is the rated current of the ABB EPX-XT2S-E2-1604?

The circuit breaker has a rated current of 160 A and uses the 160 A XT2S frame class. It is designed for appropriately rated electrical distribution circuits, subject to correct cable sizing, load assessment and protective device coordination.

What is the breaking capacity of the ABB EPX-XT2S-E2-1604?

The ABB EPX-XT2S-E2-1604 has a specified 50 kA short-circuit breaking capacity. The corresponding ABB XT2S160 LSI circuit breaker has an ultimate short-circuit breaking capacity of 50 kA at 415 V AC. Suitability must be checked against the installation's operating voltage and prospective fault current.

What does LSI mean on this ABB MCCB?

LSI identifies three electronic protection functions: L for long-time overload protection, S for short-time delayed short-circuit protection and I for instantaneous short-circuit protection. These functions allow the circuit breaker to respond to different electrical fault conditions.

What is the difference between ABB LS/I and LSI trip units?

An LS/I trip unit provides long-time overload protection with a choice between short-time delayed and instantaneous short-circuit protection. An LSI trip unit, as fitted to the EPX-XT2S-E2-1604, includes all three protection characteristics, offering greater flexibility for protective device coordination.

Is the ABB EPX-XT2S-E2-1604 a thermal-magnetic MCCB?

No. The EPX-XT2S-E2-1604 uses an ABB Ekip DIP LSI electronic trip unit rather than a conventional thermal-magnetic release. Electronic protection provides configurable overload and short-circuit protection characteristics for appropriately designed electrical installations.

Does the ABB EPX-XT2S-E2-1604 have a fully rated neutral?

Yes. The corresponding ABB XT2S160 four-pole LSI configuration features a 100% rated neutral, meaning the neutral has a current rating equal to the phase current rating. This supports appropriately designed three-phase distribution systems requiring full neutral protection.

What is the ABB order code for the EPX-XT2S-E2-1604?

The ABB Protecta Power manufacturer order code is 1SDX255178R1. The corresponding ABB XT2S160 electronic circuit breaker reference is 1SDA067850R1. The product reference EPX-XT2S-E2-1604 identifies the 160 A, four-pole, 50 kA electronic LSI MCCB.

What circuit breaker series does the EPX-XT2S-E2-1604 belong to?

The product belongs to the ABB SACE Tmax XT2S series and uses the XT2S160 circuit breaker platform. This is a 160 A frame-class MCCB fitted with a 160 A electronic LSI trip unit.

What is the width of the ABB EPX-XT2S-E2-1604?

The ABB EPX-XT2S-E2-1604 uses the 120 mm wide four-pole XT2S format. This compact construction supports efficient integration into compatible ABB Protecta Power distribution boards and low-voltage switchgear assemblies.

Where is the ABB EPX-XT2S-E2-1604 typically installed?

This MCCB is typically installed within compatible commercial distribution boards, industrial electrical panels and low-voltage switchgear assemblies. It is particularly suitable for 160 A distribution circuits requiring electronic LSI protection and high short-circuit interruption capability.

Trusted by Electrical Professionals Worldwide

ABB is an established manufacturer of electrical protection and power distribution equipment. The ABB Protecta Power Devices range, including the EPX-XT2S-E2-1604 electronic LSI MCCB, provides electrical contractors, panel builders and facilities engineers with flexible circuit protection solutions for commercial and industrial low-voltage distribution systems.