ABB EPX-XT2S-E2-0254 is a 25 A four-pole moulded case circuit breaker with a specified 50 kA short-circuit breaking capacity and an Ekip LSI electronic trip unit. Part of the ABB Protecta Power Devices range, it provides configurable long-time overload, short-time delayed and instantaneous short-circuit protection for commercial and industrial low-voltage electrical distribution systems.
£1,664.74
The ABB EPX-XT2S-E2-0254 is a high-performance 25 A four-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Combining a 50 kA short-circuit breaking capacity with an advanced ABB Ekip LSI electronic trip unit, this circuit breaker delivers configurable protection for installations requiring a relatively low rated current alongside substantial fault-current interruption capability.
Part of the ABB Protecta Power Devices range, the EPX-XT2S-E2-0254 incorporates the established ABB SACE Tmax XT2S circuit breaker platform. Its electronic protection release provides three important overcurrent protection functions: long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). These functions offer greater protection-setting flexibility than a conventional thermal-magnetic release and support effective coordination within appropriately designed electrical distribution systems.
With its 25 A rated current, four-pole configuration and 50 kA breaking capacity, the ABB EPX-XT2S-E2-0254 is particularly suitable for three-phase distribution circuits requiring four-pole switching and electronic overcurrent protection. Its compact XT2S construction supports installation within compatible ABB Protecta Power distribution boards, commercial switchgear and industrial electrical panels. Identified by ABB order code 1SDX255175R1, this MCCB provides a professional circuit protection solution for demanding low-voltage applications.
The ABB EPX-XT2S-E2-0254 combines the mechanical switching and fault-interruption capabilities of the ABB SACE Tmax XT2S platform with an Ekip LSI electronic trip unit. This protection system monitors current and initiates circuit breaker tripping when the configured protection conditions are reached. Its combination of long-time, short-time delayed and instantaneous functions provides flexibility for electrical distribution systems requiring dependable overcurrent protection and effective coordination between protective devices.
The long-time overload protection function (L) responds to sustained current levels above the selected protection threshold. Its inverse-time operating characteristic means that higher overload currents generally produce shorter tripping times. This helps protect conductors and connected equipment against excessive heating while allowing the protective response to be matched to the requirements of the circuit.
For the 25 A rated electronic release, the long-time protection settings must be selected according to the connected circuit's conductor current-carrying capacity, expected load and installation conditions. The exact adjustment positions and time characteristics depend on the fitted Ekip LSI release. Electrical designers should use ABB's published protection curves rather than assuming that the nominal 25 A rating represents every available overload setting.
The short-time delayed protection function (S) provides short-circuit protection with a configurable delay characteristic. In appropriately designed electrical distribution systems, this can help coordinate the upstream MCCB with downstream protective devices. By allowing a downstream device an opportunity to clear a localised fault, short-time delayed protection may help reduce unnecessary interruption of unaffected circuits.
However, protective-device discrimination cannot be guaranteed simply because a circuit breaker includes an S function. Actual coordination depends on the complete distribution system, available fault current, selected protection settings and the operating characteristics of the other protective devices. ABB's published selectivity tables and time-current curves should be consulted when designing the protection arrangement.
The instantaneous short-circuit protection function (I) provides rapid tripping when the detected current reaches the selected instantaneous threshold. This function is intended to interrupt high fault currents promptly, helping limit the duration of severe short-circuit conditions. The selected threshold must take account of prospective fault current, connected equipment and any permissible transient currents associated with the load.
A significant advantage of the Ekip LSI configuration is that it incorporates long-time (L), short-time delayed (S) and instantaneous (I) protection functions. Unlike an Ekip LS/I release, which provides a selectable choice between S and I characteristics, an LSI release includes both short-circuit protection functions within its protection arrangement. This additional flexibility can be valuable where the electrical distribution design requires delayed short-circuit protection alongside rapid instantaneous fault interruption.
The XT2S breaking-capacity classification provides a specified 50 kA short-circuit breaking capacity. For the corresponding ABB SACE Tmax XT2S IEC electronic breaker, both the rated ultimate breaking capacity (Icu) and rated service breaking capacity (Ics) are 50 kA at 415 V AC. This provides substantial fault-current interruption capability even though the installed electronic protection release is rated at only 25 A.
The distinction between rated current and breaking capacity is particularly important for this product. The 25 A rating relates to the current rating of the protective release, while the 50 kA breaking capacity describes the circuit breaker's ability to interrupt a short-circuit fault under specified conditions. A lower-current outgoing circuit can still be exposed to a substantial prospective short-circuit current, depending on the electrical supply and installation arrangement.
Short-circuit breaking capacity is dependent on operating voltage. For the corresponding XT2S IEC breaker, the ultimate breaking capacity is 50 kA at 380–440 V AC, 36 kA at 500 V AC, 25 kA at 525 V AC and 12 kA at 690 V AC. The installation's calculated prospective fault current must be compared with the applicable voltage-dependent rating, and the relevant Icu and Ics values must be verified against ABB's technical documentation.
The four-pole configuration supports coordinated switching of four conductors, typically three phase conductors and a neutral conductor in an appropriately designed three-phase electrical distribution system. This can be useful where neutral isolation is required alongside phase switching. However, four-pole construction does not automatically establish the neutral conductor's electronic sensing or overcurrent protection characteristics. The exact neutral-pole arrangement must be confirmed against the manufacturer's documentation.
The ABB SACE Tmax XT2S 160 A frame platform provides the mechanical foundation for the 25 A electronic protection configuration. Although the XT2 frame family accommodates higher current ratings, the EPX-XT2S-E2-0254 is specifically a 25 A rated protective device. The frame rating must not be confused with the rated current of the installed release or the permissible current-carrying capacity of the protected circuit.
As part of the ABB Protecta Power Devices range, the EPX-XT2S-E2-0254 is intended for integration into compatible electrical distribution assemblies. Its compact four-pole construction and electronic protection functions support professional distribution board designs. Correct selection of mounting accessories, conductor terminations, protection settings and enclosure arrangements remains essential.
The standard Ekip LSI electronic trip unit provides overload and short-circuit protection rather than dedicated residual-current or earth-leakage protection. Where earth-leakage protection is required, an appropriately specified additional protective device or compatible arrangement must be provided. Final circuit breaker selection should be supported by fault-level calculations, conductor sizing, protective-device coordination studies and the applicable electrical installation standards.
| Product group | Protecta Power Devices |
|---|---|
| Product reference | EPX-XT2S-E2-0254 |
| ABB order code | 1SDX255175R1 |
| Product category | Moulded case circuit breaker (MCCB) |
| Manufacturer series | SACE Tmax XT2 |
| Circuit breaker designation | XT2S |
| Rated current (In) | 25 A |
| Number of poles | 4 |
| Pole configuration | 4P |
| Specified short-circuit breaking capacity | 50 kA |
| Corresponding XT2S IEC breaker ultimate breaking capacity (Icu) | 50 kA at 415 V AC |
| Corresponding XT2S IEC breaker service breaking capacity (Ics) | 50 kA at 415 V AC |
| Breaking-capacity classification | S |
| Trip unit | Ekip LSI |
| Corresponding ABB trip-unit designation | Ekip DIP LSI |
| Trip technology | Electronic overcurrent protection |
| Long-time protection function | L |
| Long-time protection purpose | Sustained overload protection |
| Long-time protection characteristic | Inverse-time |
| Short-time delayed protection function | S |
| Short-time protection purpose | Short-circuit protection with a configurable delay characteristic |
| Instantaneous protection function | I |
| Instantaneous protection purpose | Rapid short-circuit fault interruption |
| Protection configuration | L, S and I functions |
| Trip-unit settings | Adjustable within the ranges specified for the fitted Ekip LSI release |
| Overcurrent sensing | Electronic |
| Frame family | XT2S |
| XT2 frame rating | 160 A |
| Rated protective current | 25 A |
| Corresponding XT2S four-pole width | 120 mm |
| Corresponding XT2S platform rated operational voltage | Up to 690 V AC |
| Corresponding XT2S platform rated insulation voltage (Ui) | 1,000 V |
| Corresponding XT2S platform rated impulse withstand voltage (Uimp) | 8 kV |
| Corresponding XT2S platform rated frequency | 50/60 Hz |
| Corresponding XT2S platform current type | AC |
| Corresponding XT2S IEC breaker Icu at 380–440 V AC | 50 kA |
| Corresponding XT2S IEC breaker Icu at 500 V AC | 36 kA |
| Corresponding XT2S IEC breaker Icu at 525 V AC | 25 kA |
| Corresponding XT2S IEC breaker Icu at 690 V AC | 12 kA |
| Corresponding mounting configuration | Fixed |
| Corresponding terminal configuration | Front terminals |
| Operating mechanism | Manual toggle-operated circuit breaker |
| Switching arrangement | Four-pole operation |
| Neutral-pole protection | Verify the exact neutral sensing and protection arrangement against ABB documentation |
| Residual-current protection | Not a standard LSI trip function |
| Applicable circuit breaker standard | IEC/EN 60947-2 |
| Typical application | Commercial and industrial low-voltage three-phase electrical distribution |
The ABB EPX-XT2S-E2-0254 is a 25 A four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It uses an Ekip LSI electronic trip unit and is suitable for compatible commercial and industrial distribution assemblies, including ABB Protecta Power systems.
The EPX-XT2S-E2-0254 has a 25 A rated current. Its electronic long-time overload protection can be configured according to the available Ekip LSI settings and the requirements of the protected circuit.
The ABB EPX-XT2S-E2-0254 has a specified 50 kA short-circuit breaking capacity. The corresponding XT2S IEC electronic breaker configuration has rated ultimate and service breaking capacities of 50 kA at 415 V AC. The applicable rating must be checked against the installation voltage and prospective fault current.
Ekip LSI is an ABB electronic trip-unit configuration providing three overcurrent protection functions: long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). These functions provide configurable protection for appropriately designed electrical distribution systems.
Ekip LSI provides long-time, short-time delayed and instantaneous protection functions within the same trip-unit configuration. Ekip LS/I provides long-time protection together with a selectable choice between short-time delayed and instantaneous short-circuit protection. LSI is therefore more suitable where both S and I functions are required.
Yes. The short-time delayed protection function can support coordination between upstream and downstream protective devices in suitable installations. However, actual discrimination depends on the complete electrical system, selected protection settings and the relevant ABB coordination data.
XT2S and XT2N identify different breaking-capacity variants within the ABB SACE Tmax XT2 range. Corresponding XT2S configurations provide a 50 kA breaking capacity at 415 V AC, compared with 36 kA for XT2N configurations. The correct selection depends on the installation voltage and prospective short-circuit current.
The 25 A rated current identifies the rating of the installed electronic protection release, while the 50 kA breaking capacity describes the circuit breaker's ability to interrupt a short-circuit fault under specified conditions. Even a relatively low-current outgoing circuit may be exposed to a substantial prospective fault current, depending on the electrical supply arrangement.
The four-pole (4P) configuration supports coordinated switching of four conductors, typically three phase conductors and a neutral conductor in a three-phase electrical distribution system. It is useful where neutral isolation is required, subject to the manufacturer's neutral-pole arrangement and applicable electrical regulations.
The standard Ekip LSI electronic trip unit provides overload and short-circuit protection rather than dedicated residual-current or earth-leakage protection. Where earth-leakage protection is required, an appropriately specified additional protective device or compatible arrangement must be provided.
The ABB manufacturer order code is 1SDX255175R1. The corresponding product reference is EPX-XT2S-E2-0254, identifying the 25 A, four-pole, 50 kA Ekip LSI electronic MCCB within the ABB Protecta Power Devices range.
The ABB EPX-XT2S-E2-0254 combines a 25 A four-pole configuration, 50 kA short-circuit breaking capacity and advanced Ekip LSI electronic protection in a compact SACE Tmax XT2S moulded case circuit breaker. Designed for compatible ABB Protecta Power assemblies, it provides configurable long-time overload, short-time delayed and instantaneous short-circuit protection for professionally specified commercial and industrial low-voltage electrical distribution systems.