1SDX255175R1 ABB EPX-XT2S-E2-0254 25A 4P 50kA MCCB - Ekip LSI

1SDX255175R1 ABB EPX-XT2S-E2-0254 25A 4P 50kA MCCB – Ekip LSI

ABB EPX-XT2S-E2-0254 is a 25 A four-pole moulded case circuit breaker with a specified 50 kA short-circuit breaking capacity and an Ekip LSI electronic trip unit. Part of the ABB Protecta Power Devices range, it provides configurable long-time overload, short-time delayed and instantaneous short-circuit protection for commercial and industrial low-voltage electrical distribution systems.

SKU: 1SDX255175R1Alt SKU: EPX-XT2S-E2-0254MPN: 1SDX255175R1
Price
List Price £1,664.74 ex VAT
Your Price (ex VAT)
£1,664.74
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,664.74
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,664.74

Why Choose the ABB EPX-XT2S-E2-0254 25A 4-Pole 50kA MCCB with Ekip LSI Protection?

The ABB EPX-XT2S-E2-0254 is a high-performance 25 A four-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Combining a 50 kA short-circuit breaking capacity with an advanced ABB Ekip LSI electronic trip unit, this circuit breaker delivers configurable protection for installations requiring a relatively low rated current alongside substantial fault-current interruption capability.

Part of the ABB Protecta Power Devices range, the EPX-XT2S-E2-0254 incorporates the established ABB SACE Tmax XT2S circuit breaker platform. Its electronic protection release provides three important overcurrent protection functions: long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). These functions offer greater protection-setting flexibility than a conventional thermal-magnetic release and support effective coordination within appropriately designed electrical distribution systems.

With its 25 A rated current, four-pole configuration and 50 kA breaking capacity, the ABB EPX-XT2S-E2-0254 is particularly suitable for three-phase distribution circuits requiring four-pole switching and electronic overcurrent protection. Its compact XT2S construction supports installation within compatible ABB Protecta Power distribution boards, commercial switchgear and industrial electrical panels. Identified by ABB order code 1SDX255175R1, this MCCB provides a professional circuit protection solution for demanding low-voltage applications.

Key Advantages

  • 25 A rated current provides electronic overcurrent protection for appropriately designed lower-current distribution circuits.
  • Four-pole (4P) configuration supports coordinated switching of three phase conductors and a neutral conductor.
  • 50 kA short-circuit breaking capacity offers substantial fault-current interruption capability.
  • Ekip LSI electronic trip unit combines long-time, short-time delayed and instantaneous protection functions.
  • Adjustable long-time overload protection (L) enables protection settings to be selected according to circuit requirements.
  • Short-time delayed short-circuit protection (S) supports protective-device coordination where suitable.
  • Instantaneous short-circuit protection (I) provides rapid tripping when the selected fault-current threshold is reached.
  • Combined LSI protection provides all three overcurrent protection functions within one electronic release.
  • Electronic current sensing offers configurable protection characteristics.
  • ABB SACE Tmax XT2S technology combines established mechanical switching with advanced electronic protection.
  • S breaking-capacity classification provides a higher specified breaking capacity than corresponding XT2N 36 kA configurations.
  • Compact 120 mm four-pole format supports efficient use of space within compatible distribution assemblies.
  • 160 A XT2 frame platform provides a robust mechanical foundation for the 25 A electronic protection configuration.
  • Manual toggle-operated mechanism supports straightforward local switching and resetting.
  • Designed for integration into compatible ABB Protecta Power distribution systems.

Key Features

  • ABB Protecta Power Devices product group.
  • ABB SACE Tmax XT2S moulded case circuit breaker platform.
  • 25 A rated current.
  • Four-pole (4P) configuration.
  • 50 kA specified short-circuit breaking capacity.
  • Ekip LSI electronic overcurrent protection release.
  • Long-time overload protection (L).
  • Adjustable long-time protection settings.
  • Short-time delayed short-circuit protection (S).
  • Configurable short-time protection characteristics.
  • Instantaneous short-circuit protection (I).
  • Configurable instantaneous protection threshold.
  • Combined LSI protection arrangement incorporating all three functions.
  • Electronic overcurrent sensing rather than conventional thermal-magnetic tripping.
  • Protection coordination capability for professionally designed distribution systems.
  • XT2S 160 A frame platform with a 25 A electronic protection release.
  • Four-pole construction for appropriate three-phase and neutral distribution arrangements.
  • 120 mm nominal four-pole width.
  • Fixed-mounted circuit breaker configuration on the corresponding ABB XT2S LSI platform.
  • Front-terminal connection arrangement on the corresponding ABB XT2S LSI platform.
  • Manual toggle-operated switching mechanism.
  • Mechanical operating and trip indication.
  • Corresponding XT2S platform operational voltage: Up to 690 V AC.
  • Based on circuit breaker technology designed to meet IEC/EN 60947-2.
  • ABB manufacturer order code: 1SDX255175R1.

Advanced 25A Ekip LSI Electronic Protection with 50kA Breaking Capacity

The ABB EPX-XT2S-E2-0254 combines the mechanical switching and fault-interruption capabilities of the ABB SACE Tmax XT2S platform with an Ekip LSI electronic trip unit. This protection system monitors current and initiates circuit breaker tripping when the configured protection conditions are reached. Its combination of long-time, short-time delayed and instantaneous functions provides flexibility for electrical distribution systems requiring dependable overcurrent protection and effective coordination between protective devices.

The long-time overload protection function (L) responds to sustained current levels above the selected protection threshold. Its inverse-time operating characteristic means that higher overload currents generally produce shorter tripping times. This helps protect conductors and connected equipment against excessive heating while allowing the protective response to be matched to the requirements of the circuit.

For the 25 A rated electronic release, the long-time protection settings must be selected according to the connected circuit's conductor current-carrying capacity, expected load and installation conditions. The exact adjustment positions and time characteristics depend on the fitted Ekip LSI release. Electrical designers should use ABB's published protection curves rather than assuming that the nominal 25 A rating represents every available overload setting.

The short-time delayed protection function (S) provides short-circuit protection with a configurable delay characteristic. In appropriately designed electrical distribution systems, this can help coordinate the upstream MCCB with downstream protective devices. By allowing a downstream device an opportunity to clear a localised fault, short-time delayed protection may help reduce unnecessary interruption of unaffected circuits.

However, protective-device discrimination cannot be guaranteed simply because a circuit breaker includes an S function. Actual coordination depends on the complete distribution system, available fault current, selected protection settings and the operating characteristics of the other protective devices. ABB's published selectivity tables and time-current curves should be consulted when designing the protection arrangement.

The instantaneous short-circuit protection function (I) provides rapid tripping when the detected current reaches the selected instantaneous threshold. This function is intended to interrupt high fault currents promptly, helping limit the duration of severe short-circuit conditions. The selected threshold must take account of prospective fault current, connected equipment and any permissible transient currents associated with the load.

A significant advantage of the Ekip LSI configuration is that it incorporates long-time (L), short-time delayed (S) and instantaneous (I) protection functions. Unlike an Ekip LS/I release, which provides a selectable choice between S and I characteristics, an LSI release includes both short-circuit protection functions within its protection arrangement. This additional flexibility can be valuable where the electrical distribution design requires delayed short-circuit protection alongside rapid instantaneous fault interruption.

The XT2S breaking-capacity classification provides a specified 50 kA short-circuit breaking capacity. For the corresponding ABB SACE Tmax XT2S IEC electronic breaker, both the rated ultimate breaking capacity (Icu) and rated service breaking capacity (Ics) are 50 kA at 415 V AC. This provides substantial fault-current interruption capability even though the installed electronic protection release is rated at only 25 A.

The distinction between rated current and breaking capacity is particularly important for this product. The 25 A rating relates to the current rating of the protective release, while the 50 kA breaking capacity describes the circuit breaker's ability to interrupt a short-circuit fault under specified conditions. A lower-current outgoing circuit can still be exposed to a substantial prospective short-circuit current, depending on the electrical supply and installation arrangement.

Short-circuit breaking capacity is dependent on operating voltage. For the corresponding XT2S IEC breaker, the ultimate breaking capacity is 50 kA at 380–440 V AC, 36 kA at 500 V AC, 25 kA at 525 V AC and 12 kA at 690 V AC. The installation's calculated prospective fault current must be compared with the applicable voltage-dependent rating, and the relevant Icu and Ics values must be verified against ABB's technical documentation.

The four-pole configuration supports coordinated switching of four conductors, typically three phase conductors and a neutral conductor in an appropriately designed three-phase electrical distribution system. This can be useful where neutral isolation is required alongside phase switching. However, four-pole construction does not automatically establish the neutral conductor's electronic sensing or overcurrent protection characteristics. The exact neutral-pole arrangement must be confirmed against the manufacturer's documentation.

The ABB SACE Tmax XT2S 160 A frame platform provides the mechanical foundation for the 25 A electronic protection configuration. Although the XT2 frame family accommodates higher current ratings, the EPX-XT2S-E2-0254 is specifically a 25 A rated protective device. The frame rating must not be confused with the rated current of the installed release or the permissible current-carrying capacity of the protected circuit.

As part of the ABB Protecta Power Devices range, the EPX-XT2S-E2-0254 is intended for integration into compatible electrical distribution assemblies. Its compact four-pole construction and electronic protection functions support professional distribution board designs. Correct selection of mounting accessories, conductor terminations, protection settings and enclosure arrangements remains essential.

The standard Ekip LSI electronic trip unit provides overload and short-circuit protection rather than dedicated residual-current or earth-leakage protection. Where earth-leakage protection is required, an appropriately specified additional protective device or compatible arrangement must be provided. Final circuit breaker selection should be supported by fault-level calculations, conductor sizing, protective-device coordination studies and the applicable electrical installation standards.

Typical Applications

  • ABB Protecta Power distribution boards and compatible electrical assemblies.
  • Commercial low-voltage electrical distribution systems.
  • Industrial electrical distribution panels and switchgear.
  • Three-phase outgoing circuits requiring 25 A electronic overcurrent protection.
  • Four-pole circuits requiring coordinated switching of phase and neutral conductors.
  • Distribution circuits requiring a 50 kA short-circuit breaking capacity.
  • Commercial building sub-distribution systems.
  • Manufacturing facilities and industrial electrical infrastructure.
  • Building services and mechanical plant electrical distribution.
  • Installations requiring adjustable electronic overload protection at a relatively low rated current.
  • Distribution systems requiring short-time delayed and instantaneous short-circuit protection functions.
  • Professional installations where protective-device discrimination and coordination are important design considerations.

Technical Specifications

Product group Protecta Power Devices
Product reference EPX-XT2S-E2-0254
ABB order code 1SDX255175R1
Product category Moulded case circuit breaker (MCCB)
Manufacturer series SACE Tmax XT2
Circuit breaker designation XT2S
Rated current (In) 25 A
Number of poles 4
Pole configuration 4P
Specified short-circuit breaking capacity 50 kA
Corresponding XT2S IEC breaker ultimate breaking capacity (Icu) 50 kA at 415 V AC
Corresponding XT2S IEC breaker service breaking capacity (Ics) 50 kA at 415 V AC
Breaking-capacity classification S
Trip unit Ekip LSI
Corresponding ABB trip-unit designation Ekip DIP LSI
Trip technology Electronic overcurrent protection
Long-time protection function L
Long-time protection purpose Sustained overload protection
Long-time protection characteristic Inverse-time
Short-time delayed protection function S
Short-time protection purpose Short-circuit protection with a configurable delay characteristic
Instantaneous protection function I
Instantaneous protection purpose Rapid short-circuit fault interruption
Protection configuration L, S and I functions
Trip-unit settings Adjustable within the ranges specified for the fitted Ekip LSI release
Overcurrent sensing Electronic
Frame family XT2S
XT2 frame rating 160 A
Rated protective current 25 A
Corresponding XT2S four-pole width 120 mm
Corresponding XT2S platform rated operational voltage Up to 690 V AC
Corresponding XT2S platform rated insulation voltage (Ui) 1,000 V
Corresponding XT2S platform rated impulse withstand voltage (Uimp) 8 kV
Corresponding XT2S platform rated frequency 50/60 Hz
Corresponding XT2S platform current type AC
Corresponding XT2S IEC breaker Icu at 380–440 V AC 50 kA
Corresponding XT2S IEC breaker Icu at 500 V AC 36 kA
Corresponding XT2S IEC breaker Icu at 525 V AC 25 kA
Corresponding XT2S IEC breaker Icu at 690 V AC 12 kA
Corresponding mounting configuration Fixed
Corresponding terminal configuration Front terminals
Operating mechanism Manual toggle-operated circuit breaker
Switching arrangement Four-pole operation
Neutral-pole protection Verify the exact neutral sensing and protection arrangement against ABB documentation
Residual-current protection Not a standard LSI trip function
Applicable circuit breaker standard IEC/EN 60947-2
Typical application Commercial and industrial low-voltage three-phase electrical distribution

Frequently Asked Questions

What is the ABB EPX-XT2S-E2-0254 used for?

The ABB EPX-XT2S-E2-0254 is a 25 A four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It uses an Ekip LSI electronic trip unit and is suitable for compatible commercial and industrial distribution assemblies, including ABB Protecta Power systems.

What is the rated current of the ABB EPX-XT2S-E2-0254?

The EPX-XT2S-E2-0254 has a 25 A rated current. Its electronic long-time overload protection can be configured according to the available Ekip LSI settings and the requirements of the protected circuit.

What is the short-circuit breaking capacity of this MCCB?

The ABB EPX-XT2S-E2-0254 has a specified 50 kA short-circuit breaking capacity. The corresponding XT2S IEC electronic breaker configuration has rated ultimate and service breaking capacities of 50 kA at 415 V AC. The applicable rating must be checked against the installation voltage and prospective fault current.

What does Ekip LSI mean?

Ekip LSI is an ABB electronic trip-unit configuration providing three overcurrent protection functions: long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). These functions provide configurable protection for appropriately designed electrical distribution systems.

What is the difference between Ekip LSI and Ekip LS/I?

Ekip LSI provides long-time, short-time delayed and instantaneous protection functions within the same trip-unit configuration. Ekip LS/I provides long-time protection together with a selectable choice between short-time delayed and instantaneous short-circuit protection. LSI is therefore more suitable where both S and I functions are required.

Can Ekip LSI help improve protective-device discrimination?

Yes. The short-time delayed protection function can support coordination between upstream and downstream protective devices in suitable installations. However, actual discrimination depends on the complete electrical system, selected protection settings and the relevant ABB coordination data.

What is the difference between XT2S and XT2N MCCBs?

XT2S and XT2N identify different breaking-capacity variants within the ABB SACE Tmax XT2 range. Corresponding XT2S configurations provide a 50 kA breaking capacity at 415 V AC, compared with 36 kA for XT2N configurations. The correct selection depends on the installation voltage and prospective short-circuit current.

Why does a 25A circuit breaker have a 50kA breaking capacity?

The 25 A rated current identifies the rating of the installed electronic protection release, while the 50 kA breaking capacity describes the circuit breaker's ability to interrupt a short-circuit fault under specified conditions. Even a relatively low-current outgoing circuit may be exposed to a substantial prospective fault current, depending on the electrical supply arrangement.

What is the advantage of the four-pole configuration?

The four-pole (4P) configuration supports coordinated switching of four conductors, typically three phase conductors and a neutral conductor in a three-phase electrical distribution system. It is useful where neutral isolation is required, subject to the manufacturer's neutral-pole arrangement and applicable electrical regulations.

Does the ABB EPX-XT2S-E2-0254 provide earth-leakage protection?

The standard Ekip LSI electronic trip unit provides overload and short-circuit protection rather than dedicated residual-current or earth-leakage protection. Where earth-leakage protection is required, an appropriately specified additional protective device or compatible arrangement must be provided.

What is the ABB order code for the EPX-XT2S-E2-0254?

The ABB manufacturer order code is 1SDX255175R1. The corresponding product reference is EPX-XT2S-E2-0254, identifying the 25 A, four-pole, 50 kA Ekip LSI electronic MCCB within the ABB Protecta Power Devices range.

Trusted ABB LSI Electronic Circuit Protection for Professional Installations

The ABB EPX-XT2S-E2-0254 combines a 25 A four-pole configuration, 50 kA short-circuit breaking capacity and advanced Ekip LSI electronic protection in a compact SACE Tmax XT2S moulded case circuit breaker. Designed for compatible ABB Protecta Power assemblies, it provides configurable long-time overload, short-time delayed and instantaneous short-circuit protection for professionally specified commercial and industrial low-voltage electrical distribution systems.