ABB EPX-XT2S-E2-1603 is a 160 A three-pole moulded case circuit breaker with a specified 50 kA short-circuit breaking capacity and an Ekip LSI electronic trip unit. Part of the ABB Protecta Power Devices range, it provides configurable long-time overload, short-time delayed and instantaneous short-circuit protection for commercial and industrial low-voltage electrical distribution systems.
£1,574.29
The ABB EPX-XT2S-E2-1603 is a high-performance 160 A three-pole moulded case circuit breaker (MCCB) designed to deliver dependable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Combining a 50 kA short-circuit breaking capacity with an advanced ABB Ekip LSI electronic trip unit, this circuit breaker offers configurable protection for installations requiring substantial fault-current interruption capability and effective protective-device coordination.
Part of the ABB Protecta Power Devices range, the EPX-XT2S-E2-1603 incorporates the established ABB SACE Tmax XT2S circuit breaker platform. Its electronic protection release provides three essential overcurrent protection functions: long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). Unlike an LS/I release, which offers a choice between S and I protection, the LSI configuration provides all three functions as part of its protection arrangement.
With its 160 A rated current, three-pole configuration and 50 kA breaking capacity, the ABB EPX-XT2S-E2-1603 is suitable for appropriately designed three-phase distribution circuits in commercial switchboards, industrial electrical panels and compatible ABB Protecta Power assemblies. Identified by ABB order code 1SDX255174R1, this electronic MCCB provides advanced circuit protection in a compact XT2S format.
The ABB EPX-XT2S-E2-1603 combines the mechanical switching and fault-interruption capabilities of the ABB SACE Tmax XT2S platform with an Ekip LSI electronic trip unit. This electronic protection system monitors current and initiates circuit breaker tripping when the configured protection conditions are reached. Its three protection functions provide flexibility for electrical distribution systems requiring dependable overload protection, short-circuit interruption and coordination between protective devices.
The long-time overload protection function (L) responds to sustained current levels above the selected protection threshold. Its inverse-time characteristic means that larger overload currents generally produce shorter tripping times. This helps protect conductors and connected equipment against excessive heating while allowing the protective response to be matched to the circuit's design requirements.
The adjustable long-time protection settings allow the 160 A electronic release to be configured according to conductor current-carrying capacity, expected loading and installation conditions. The precise adjustment positions and associated time characteristics depend on the fitted Ekip LSI release. Electrical designers should use ABB's published time-current curves when selecting settings rather than assuming that the nominal 160 A rating represents every available overload threshold.
The short-time delayed protection function (S) responds to short-circuit currents with a configurable delay characteristic. In suitable distribution systems, this can support selective coordination between upstream and downstream protective devices. By allowing a downstream breaker an opportunity to interrupt a localised fault, short-time delayed protection may help prevent unnecessary loss of supply to unaffected circuits.
Actual discrimination cannot be established from the presence of an S function alone. The complete protective-device arrangement, available fault current, selected settings and manufacturer coordination data must be assessed. ABB's published selectivity tables and time-current characteristics should be used when determining whether the EPX-XT2S-E2-1603 can achieve the required coordination with upstream and downstream devices.
The instantaneous short-circuit protection function (I) provides rapid tripping when the current reaches the selected instantaneous threshold. This function is intended to interrupt high fault currents promptly, helping limit the duration of severe short-circuit conditions. The selected threshold must take account of the installation's prospective fault current, connected equipment and any permissible transient currents.
A major advantage of the Ekip LSI configuration is that it incorporates long-time (L), short-time delayed (S) and instantaneous (I) protection functions. Unlike an Ekip LS/I release, which provides a selectable choice between S and I characteristics, an LSI release offers both short-circuit protection functions within its protection arrangement. This additional flexibility is valuable where the distribution design requires coordinated delayed protection alongside rapid instantaneous fault interruption.
The XT2S breaking-capacity classification provides a specified 50 kA short-circuit breaking capacity. For the corresponding ABB SACE Tmax XT2S IEC electronic breaker, both the rated ultimate breaking capacity (Icu) and rated service breaking capacity (Ics) are 50 kA at 415 V AC. This makes the device suitable for consideration in installations with substantial prospective fault currents, provided the applicable voltage-dependent ratings and installation requirements are satisfied.
Short-circuit breaking capacity is dependent on operating voltage. For the corresponding XT2S IEC breaker, the ultimate breaking capacity is 50 kA at 380–440 V AC, 36 kA at 500 V AC, 25 kA at 525 V AC and 12 kA at 690 V AC. The installation's calculated prospective short-circuit current must be compared with the appropriate rating for the actual system voltage, and the relevant Icu and Ics values must be confirmed against ABB's technical data.
The three-pole configuration provides coordinated switching and protection of three phase conductors in appropriately designed three-phase electrical distribution systems. Because the EPX-XT2S-E2-1603 is a three-pole MCCB, it does not incorporate a fourth switched neutral pole. Where neutral switching or isolation is required, a suitable four-pole circuit breaker should be considered.
The ABB SACE Tmax XT2S 160 A frame platform provides the mechanical foundation for the 160 A electronic protection configuration. In this case, the frame rating and the rated protective current are both 160 A. Nevertheless, the permissible operating current of the protected circuit must still be determined from conductor ratings, installation conditions, enclosure temperature and the manufacturer's application guidance.
As part of the ABB Protecta Power Devices range, the EPX-XT2S-E2-1603 is intended for integration into compatible electrical distribution assemblies. The corresponding fixed-mounted XT2S electronic breaker uses front terminals, supporting practical installation in suitable switchboards. Correct selection of mounting accessories, conductor terminations, protection settings and enclosure arrangements is essential.
The standard Ekip LSI electronic trip unit provides overload and short-circuit protection rather than dedicated residual-current or earth-leakage protection. Where earth-leakage protection is required, an appropriately specified additional protective device or compatible arrangement must be provided. Final circuit breaker selection should be supported by fault-level calculations, conductor sizing, protective-device coordination studies and the applicable electrical installation standards.
| Product group | Protecta Power Devices |
|---|---|
| Product reference | EPX-XT2S-E2-1603 |
| ABB order code | 1SDX255174R1 |
| Product category | Moulded case circuit breaker (MCCB) |
| Manufacturer series | SACE Tmax XT2 |
| Circuit breaker designation | XT2S |
| Rated current (In) | 160 A |
| Number of poles | 3 |
| Pole configuration | 3P |
| Specified short-circuit breaking capacity | 50 kA |
| Corresponding XT2S IEC breaker ultimate breaking capacity (Icu) | 50 kA at 415 V AC |
| Corresponding XT2S IEC breaker service breaking capacity (Ics) | 50 kA at 415 V AC |
| Breaking-capacity classification | S |
| Trip unit | Ekip LSI |
| Corresponding ABB trip-unit designation | Ekip DIP LSI |
| Trip technology | Electronic overcurrent protection |
| Long-time protection function | L |
| Long-time protection purpose | Sustained overload protection |
| Long-time protection characteristic | Inverse-time |
| Short-time delayed protection function | S |
| Short-time protection purpose | Short-circuit protection with a configurable delay characteristic |
| Instantaneous protection function | I |
| Instantaneous protection purpose | Rapid short-circuit fault interruption |
| Protection configuration | L, S and I functions |
| Trip-unit settings | Adjustable within the ranges specified for the fitted Ekip LSI release |
| Overcurrent sensing | Electronic |
| Frame family | XT2S |
| XT2 frame rating | 160 A |
| Rated protective current | 160 A |
| Corresponding XT2S three-pole width | 90 mm |
| Corresponding XT2S platform rated operational voltage | Up to 690 V AC |
| Corresponding XT2S platform rated insulation voltage (Ui) | 1,000 V |
| Corresponding XT2S platform rated impulse withstand voltage (Uimp) | 8 kV |
| Corresponding XT2S platform rated frequency | 50/60 Hz |
| Corresponding XT2S platform current type | AC |
| Corresponding XT2S IEC breaker Icu at 380–440 V AC | 50 kA |
| Corresponding XT2S IEC breaker Icu at 500 V AC | 36 kA |
| Corresponding XT2S IEC breaker Icu at 525 V AC | 25 kA |
| Corresponding XT2S IEC breaker Icu at 690 V AC | 12 kA |
| Corresponding mounting configuration | Fixed |
| Corresponding terminal configuration | Front terminals |
| Operating mechanism | Manual toggle-operated circuit breaker |
| Switching arrangement | Three-pole operation |
| Neutral switching | No fourth switched neutral pole |
| Residual-current protection | Not a standard LSI trip function |
| Applicable circuit breaker standard | IEC/EN 60947-2 |
| Typical application | Commercial and industrial low-voltage three-phase electrical distribution |
The ABB EPX-XT2S-E2-1603 is a 160 A three-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It uses an Ekip LSI electronic trip unit and is suitable for compatible commercial and industrial distribution assemblies, including ABB Protecta Power systems.
The EPX-XT2S-E2-1603 has a 160 A rated current. Its electronic long-time overload protection can be configured according to the available Ekip LSI settings and the requirements of the protected circuit.
The ABB EPX-XT2S-E2-1603 has a specified 50 kA short-circuit breaking capacity. The corresponding XT2S IEC electronic breaker configuration has rated ultimate and service breaking capacities of 50 kA at 415 V AC. The applicable rating must be checked against the installation voltage and prospective fault current.
Ekip LSI is an ABB electronic trip-unit configuration providing three overcurrent protection functions: long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). These functions provide configurable protection for appropriately designed electrical distribution systems.
Ekip LSI provides long-time, short-time delayed and instantaneous protection functions within the same trip-unit configuration. Ekip LS/I provides long-time protection together with a selectable choice between short-time delayed and instantaneous short-circuit protection. LSI is therefore more suitable where both S and I functions are required.
Yes. The short-time delayed protection function can support coordination between upstream and downstream protective devices in suitable installations. However, actual discrimination depends on the complete electrical system, selected protection settings and the relevant ABB coordination data.
XT2S and XT2N identify different breaking-capacity variants within the ABB SACE Tmax XT2 range. Corresponding XT2S configurations provide a 50 kA breaking capacity at 415 V AC, compared with 36 kA for XT2N configurations. The correct selection depends on the installation voltage and prospective short-circuit current.
Yes. Its three-pole (3P) configuration is designed for appropriately rated three-phase electrical distribution circuits requiring coordinated switching and protection of the three phase conductors. Where neutral switching is required, a suitable four-pole circuit breaker should be considered.
The standard Ekip LSI electronic trip unit provides overload and short-circuit protection rather than dedicated residual-current or earth-leakage protection. Where earth-leakage protection is required, an appropriately specified additional protective device or compatible arrangement must be provided.
The ABB manufacturer order code is 1SDX255174R1. The corresponding product reference is EPX-XT2S-E2-1603, identifying the 160 A, three-pole, 50 kA Ekip LSI electronic MCCB within the ABB Protecta Power Devices range.
The ABB EPX-XT2S-E2-1603 combines a 160 A three-pole configuration, 50 kA short-circuit breaking capacity and advanced Ekip LSI electronic protection in a compact SACE Tmax XT2S moulded case circuit breaker. Designed for compatible ABB Protecta Power assemblies, it provides configurable long-time overload, short-time delayed and instantaneous short-circuit protection for professionally specified commercial and industrial low-voltage electrical distribution systems.