1SDX255174R1 ABB EPX-XT2S-E2-1603 160A 3P 50kA MCCB - Ekip LSI

1SDX255174R1 ABB EPX-XT2S-E2-1603 160A 3P 50kA MCCB – Ekip LSI

ABB EPX-XT2S-E2-1603 is a 160 A three-pole moulded case circuit breaker with a specified 50 kA short-circuit breaking capacity and an Ekip LSI electronic trip unit. Part of the ABB Protecta Power Devices range, it provides configurable long-time overload, short-time delayed and instantaneous short-circuit protection for commercial and industrial low-voltage electrical distribution systems.

SKU: 1SDX255174R1Alt SKU: EPX-XT2S-E2-1603MPN: 1SDX255174R1
Price
List Price £1,574.29 ex VAT
Your Price (ex VAT)
£1,574.29
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,574.29
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,574.29

Why Choose the ABB EPX-XT2S-E2-1603 160A 3-Pole 50kA MCCB with Ekip LSI Protection?

The ABB EPX-XT2S-E2-1603 is a high-performance 160 A three-pole moulded case circuit breaker (MCCB) designed to deliver dependable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Combining a 50 kA short-circuit breaking capacity with an advanced ABB Ekip LSI electronic trip unit, this circuit breaker offers configurable protection for installations requiring substantial fault-current interruption capability and effective protective-device coordination.

Part of the ABB Protecta Power Devices range, the EPX-XT2S-E2-1603 incorporates the established ABB SACE Tmax XT2S circuit breaker platform. Its electronic protection release provides three essential overcurrent protection functions: long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). Unlike an LS/I release, which offers a choice between S and I protection, the LSI configuration provides all three functions as part of its protection arrangement.

With its 160 A rated current, three-pole configuration and 50 kA breaking capacity, the ABB EPX-XT2S-E2-1603 is suitable for appropriately designed three-phase distribution circuits in commercial switchboards, industrial electrical panels and compatible ABB Protecta Power assemblies. Identified by ABB order code 1SDX255174R1, this electronic MCCB provides advanced circuit protection in a compact XT2S format.

Key Advantages

  • 160 A rated current supports appropriately designed commercial and industrial three-phase distribution circuits.
  • Three-pole (3P) configuration provides coordinated switching and protection of three phase conductors.
  • 50 kA short-circuit breaking capacity offers substantial fault-current interruption capability.
  • Ekip LSI electronic trip unit combines long-time, short-time delayed and instantaneous overcurrent protection.
  • Adjustable long-time protection (L) helps protect conductors and equipment against sustained overload conditions.
  • Short-time delayed protection (S) supports protective-device coordination in suitable electrical distribution systems.
  • Instantaneous protection (I) provides rapid tripping when high short-circuit currents reach the selected threshold.
  • Independent L, S and I protection functions provide greater configuration flexibility than an LS/I release.
  • Electronic current sensing enables configurable and repeatable protection characteristics.
  • ABB SACE Tmax XT2S technology combines robust switching performance with advanced electronic protection.
  • S breaking-capacity classification offers a higher specified breaking capacity than corresponding XT2N 36 kA configurations.
  • Compact XT2S construction supports efficient use of space within compatible distribution assemblies.
  • 160 A XT2 frame platform provides a matched mechanical foundation for the rated protective current.
  • Manual operating mechanism supports straightforward local switching and resetting.
  • Designed for integration into compatible ABB Protecta Power distribution systems.

Key Features

  • ABB Protecta Power Devices product group.
  • ABB SACE Tmax XT2S moulded case circuit breaker platform.
  • 160 A rated current.
  • Three-pole (3P) configuration.
  • 50 kA specified short-circuit breaking capacity.
  • Ekip LSI electronic overcurrent protection release.
  • Long-time overload protection (L).
  • Adjustable long-time protection settings.
  • Short-time delayed short-circuit protection (S).
  • Configurable short-time protection characteristics.
  • Instantaneous short-circuit protection (I).
  • Configurable instantaneous protection threshold.
  • Combined LSI protection arrangement incorporating all three protection functions.
  • Electronic overcurrent sensing rather than conventional thermal-magnetic tripping.
  • Protection coordination capability for appropriately designed distribution systems.
  • XT2S 160 A frame platform.
  • Three-pole construction for three-phase electrical distribution.
  • Compact 90 mm nominal three-pole width on the corresponding XT2S platform.
  • Fixed-mounted circuit breaker configuration on the corresponding ABB XT2S LSI model.
  • Front-terminal connection arrangement on the corresponding ABB XT2S LSI model.
  • Manual toggle-operated switching mechanism.
  • Mechanical operating and trip indication.
  • Corresponding XT2S platform rated operational voltage: Up to 690 V AC.
  • Based on circuit breaker technology designed to meet IEC/EN 60947-2.
  • ABB manufacturer order code: 1SDX255174R1.

Advanced 160A Ekip LSI Electronic Protection with 50kA Breaking Capacity

The ABB EPX-XT2S-E2-1603 combines the mechanical switching and fault-interruption capabilities of the ABB SACE Tmax XT2S platform with an Ekip LSI electronic trip unit. This electronic protection system monitors current and initiates circuit breaker tripping when the configured protection conditions are reached. Its three protection functions provide flexibility for electrical distribution systems requiring dependable overload protection, short-circuit interruption and coordination between protective devices.

The long-time overload protection function (L) responds to sustained current levels above the selected protection threshold. Its inverse-time characteristic means that larger overload currents generally produce shorter tripping times. This helps protect conductors and connected equipment against excessive heating while allowing the protective response to be matched to the circuit's design requirements.

The adjustable long-time protection settings allow the 160 A electronic release to be configured according to conductor current-carrying capacity, expected loading and installation conditions. The precise adjustment positions and associated time characteristics depend on the fitted Ekip LSI release. Electrical designers should use ABB's published time-current curves when selecting settings rather than assuming that the nominal 160 A rating represents every available overload threshold.

The short-time delayed protection function (S) responds to short-circuit currents with a configurable delay characteristic. In suitable distribution systems, this can support selective coordination between upstream and downstream protective devices. By allowing a downstream breaker an opportunity to interrupt a localised fault, short-time delayed protection may help prevent unnecessary loss of supply to unaffected circuits.

Actual discrimination cannot be established from the presence of an S function alone. The complete protective-device arrangement, available fault current, selected settings and manufacturer coordination data must be assessed. ABB's published selectivity tables and time-current characteristics should be used when determining whether the EPX-XT2S-E2-1603 can achieve the required coordination with upstream and downstream devices.

The instantaneous short-circuit protection function (I) provides rapid tripping when the current reaches the selected instantaneous threshold. This function is intended to interrupt high fault currents promptly, helping limit the duration of severe short-circuit conditions. The selected threshold must take account of the installation's prospective fault current, connected equipment and any permissible transient currents.

A major advantage of the Ekip LSI configuration is that it incorporates long-time (L), short-time delayed (S) and instantaneous (I) protection functions. Unlike an Ekip LS/I release, which provides a selectable choice between S and I characteristics, an LSI release offers both short-circuit protection functions within its protection arrangement. This additional flexibility is valuable where the distribution design requires coordinated delayed protection alongside rapid instantaneous fault interruption.

The XT2S breaking-capacity classification provides a specified 50 kA short-circuit breaking capacity. For the corresponding ABB SACE Tmax XT2S IEC electronic breaker, both the rated ultimate breaking capacity (Icu) and rated service breaking capacity (Ics) are 50 kA at 415 V AC. This makes the device suitable for consideration in installations with substantial prospective fault currents, provided the applicable voltage-dependent ratings and installation requirements are satisfied.

Short-circuit breaking capacity is dependent on operating voltage. For the corresponding XT2S IEC breaker, the ultimate breaking capacity is 50 kA at 380–440 V AC, 36 kA at 500 V AC, 25 kA at 525 V AC and 12 kA at 690 V AC. The installation's calculated prospective short-circuit current must be compared with the appropriate rating for the actual system voltage, and the relevant Icu and Ics values must be confirmed against ABB's technical data.

The three-pole configuration provides coordinated switching and protection of three phase conductors in appropriately designed three-phase electrical distribution systems. Because the EPX-XT2S-E2-1603 is a three-pole MCCB, it does not incorporate a fourth switched neutral pole. Where neutral switching or isolation is required, a suitable four-pole circuit breaker should be considered.

The ABB SACE Tmax XT2S 160 A frame platform provides the mechanical foundation for the 160 A electronic protection configuration. In this case, the frame rating and the rated protective current are both 160 A. Nevertheless, the permissible operating current of the protected circuit must still be determined from conductor ratings, installation conditions, enclosure temperature and the manufacturer's application guidance.

As part of the ABB Protecta Power Devices range, the EPX-XT2S-E2-1603 is intended for integration into compatible electrical distribution assemblies. The corresponding fixed-mounted XT2S electronic breaker uses front terminals, supporting practical installation in suitable switchboards. Correct selection of mounting accessories, conductor terminations, protection settings and enclosure arrangements is essential.

The standard Ekip LSI electronic trip unit provides overload and short-circuit protection rather than dedicated residual-current or earth-leakage protection. Where earth-leakage protection is required, an appropriately specified additional protective device or compatible arrangement must be provided. Final circuit breaker selection should be supported by fault-level calculations, conductor sizing, protective-device coordination studies and the applicable electrical installation standards.

Typical Applications

  • ABB Protecta Power distribution boards and compatible electrical assemblies.
  • Commercial low-voltage electrical distribution systems.
  • Industrial electrical distribution panels and switchgear.
  • Three-phase outgoing circuits requiring 160 A electronic overcurrent protection.
  • Distribution circuits requiring a 50 kA short-circuit breaking capacity.
  • Commercial building main and sub-distribution systems.
  • Manufacturing facilities and industrial electrical infrastructure.
  • Mechanical plant and building services electrical distribution.
  • Installations requiring adjustable electronic overload protection.
  • Distribution systems requiring short-time delayed short-circuit protection.
  • Electrical installations requiring instantaneous short-circuit protection alongside delayed protection.
  • Professional installations where protective-device discrimination and coordination are important design considerations.

Technical Specifications

Product group Protecta Power Devices
Product reference EPX-XT2S-E2-1603
ABB order code 1SDX255174R1
Product category Moulded case circuit breaker (MCCB)
Manufacturer series SACE Tmax XT2
Circuit breaker designation XT2S
Rated current (In) 160 A
Number of poles 3
Pole configuration 3P
Specified short-circuit breaking capacity 50 kA
Corresponding XT2S IEC breaker ultimate breaking capacity (Icu) 50 kA at 415 V AC
Corresponding XT2S IEC breaker service breaking capacity (Ics) 50 kA at 415 V AC
Breaking-capacity classification S
Trip unit Ekip LSI
Corresponding ABB trip-unit designation Ekip DIP LSI
Trip technology Electronic overcurrent protection
Long-time protection function L
Long-time protection purpose Sustained overload protection
Long-time protection characteristic Inverse-time
Short-time delayed protection function S
Short-time protection purpose Short-circuit protection with a configurable delay characteristic
Instantaneous protection function I
Instantaneous protection purpose Rapid short-circuit fault interruption
Protection configuration L, S and I functions
Trip-unit settings Adjustable within the ranges specified for the fitted Ekip LSI release
Overcurrent sensing Electronic
Frame family XT2S
XT2 frame rating 160 A
Rated protective current 160 A
Corresponding XT2S three-pole width 90 mm
Corresponding XT2S platform rated operational voltage Up to 690 V AC
Corresponding XT2S platform rated insulation voltage (Ui) 1,000 V
Corresponding XT2S platform rated impulse withstand voltage (Uimp) 8 kV
Corresponding XT2S platform rated frequency 50/60 Hz
Corresponding XT2S platform current type AC
Corresponding XT2S IEC breaker Icu at 380–440 V AC 50 kA
Corresponding XT2S IEC breaker Icu at 500 V AC 36 kA
Corresponding XT2S IEC breaker Icu at 525 V AC 25 kA
Corresponding XT2S IEC breaker Icu at 690 V AC 12 kA
Corresponding mounting configuration Fixed
Corresponding terminal configuration Front terminals
Operating mechanism Manual toggle-operated circuit breaker
Switching arrangement Three-pole operation
Neutral switching No fourth switched neutral pole
Residual-current protection Not a standard LSI trip function
Applicable circuit breaker standard IEC/EN 60947-2
Typical application Commercial and industrial low-voltage three-phase electrical distribution

Frequently Asked Questions

What is the ABB EPX-XT2S-E2-1603 used for?

The ABB EPX-XT2S-E2-1603 is a 160 A three-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It uses an Ekip LSI electronic trip unit and is suitable for compatible commercial and industrial distribution assemblies, including ABB Protecta Power systems.

What is the rated current of the ABB EPX-XT2S-E2-1603?

The EPX-XT2S-E2-1603 has a 160 A rated current. Its electronic long-time overload protection can be configured according to the available Ekip LSI settings and the requirements of the protected circuit.

What is the short-circuit breaking capacity of this MCCB?

The ABB EPX-XT2S-E2-1603 has a specified 50 kA short-circuit breaking capacity. The corresponding XT2S IEC electronic breaker configuration has rated ultimate and service breaking capacities of 50 kA at 415 V AC. The applicable rating must be checked against the installation voltage and prospective fault current.

What does Ekip LSI mean?

Ekip LSI is an ABB electronic trip-unit configuration providing three overcurrent protection functions: long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). These functions provide configurable protection for appropriately designed electrical distribution systems.

What is the difference between Ekip LSI and Ekip LS/I?

Ekip LSI provides long-time, short-time delayed and instantaneous protection functions within the same trip-unit configuration. Ekip LS/I provides long-time protection together with a selectable choice between short-time delayed and instantaneous short-circuit protection. LSI is therefore more suitable where both S and I functions are required.

Can Ekip LSI help improve protective-device discrimination?

Yes. The short-time delayed protection function can support coordination between upstream and downstream protective devices in suitable installations. However, actual discrimination depends on the complete electrical system, selected protection settings and the relevant ABB coordination data.

What is the difference between XT2S and XT2N MCCBs?

XT2S and XT2N identify different breaking-capacity variants within the ABB SACE Tmax XT2 range. Corresponding XT2S configurations provide a 50 kA breaking capacity at 415 V AC, compared with 36 kA for XT2N configurations. The correct selection depends on the installation voltage and prospective short-circuit current.

Is the ABB EPX-XT2S-E2-1603 suitable for three-phase distribution systems?

Yes. Its three-pole (3P) configuration is designed for appropriately rated three-phase electrical distribution circuits requiring coordinated switching and protection of the three phase conductors. Where neutral switching is required, a suitable four-pole circuit breaker should be considered.

Does the ABB EPX-XT2S-E2-1603 provide earth-leakage protection?

The standard Ekip LSI electronic trip unit provides overload and short-circuit protection rather than dedicated residual-current or earth-leakage protection. Where earth-leakage protection is required, an appropriately specified additional protective device or compatible arrangement must be provided.

What is the ABB order code for the EPX-XT2S-E2-1603?

The ABB manufacturer order code is 1SDX255174R1. The corresponding product reference is EPX-XT2S-E2-1603, identifying the 160 A, three-pole, 50 kA Ekip LSI electronic MCCB within the ABB Protecta Power Devices range.

Trusted ABB LSI Electronic Circuit Protection for Professional Installations

The ABB EPX-XT2S-E2-1603 combines a 160 A three-pole configuration, 50 kA short-circuit breaking capacity and advanced Ekip LSI electronic protection in a compact SACE Tmax XT2S moulded case circuit breaker. Designed for compatible ABB Protecta Power assemblies, it provides configurable long-time overload, short-time delayed and instantaneous short-circuit protection for professionally specified commercial and industrial low-voltage electrical distribution systems.