1SDX255167R1 ABB EPX-XT5S-E1-3204 320A 4-Pole 50kA MCCB Ekip LS/I

1SDX255167R1 ABB EPX-XT5S-E1-3204 320A 4-Pole 50kA MCCB Ekip LS/I

ABB EPX-XT5S-E1-3204 is a 320 A four-pole Tmax XT5S 400 moulded case circuit breaker with 50 kA breaking capacity and Ekip Dip LS/I electronic protection for commercial and industrial low-voltage power distribution systems.

SKU: 1SDX255167R1Alt SKU: EPX-XT5S-E1-3204MPN: 1SDX255167R1
Price
List Price £1,910.84 ex VAT
Your Price (ex VAT)
£1,910.84
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,910.84
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,910.84

Why Choose the ABB EPX-XT5S-E1-3204 320A 4-Pole 50kA MCCB?

The ABB EPX-XT5S-E1-3204 is a high-performance 320 A four-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. Featuring a 50 kA breaking capacity and advanced electronic LS/I protection, this circuit breaker is suitable for commercial, industrial and building electrical installations requiring dependable power distribution protection.

As part of the ABB Protecta Power distribution range, the EPX-XT5S-E1-3204 incorporates the robust ABB Tmax XT5S circuit breaker platform with an Ekip Dip LS/I electronic trip unit. This protection system provides long-time overload protection together with selectable short-time or instantaneous short-circuit protection, allowing electrical engineers to configure protection characteristics according to installation requirements.

With a 320 A rated current, four-pole configuration and 50 kA short-circuit breaking capacity, the EPX-XT5S-E1-3204 is designed for integration into low-voltage switchboards, distribution panels and ABB Protecta Power assemblies. Its XT5S 400 frame provides a robust solution for higher-current distribution circuits, while the four-pole arrangement supports applications requiring switching and protection arrangements incorporating a neutral conductor.

Key Advantages

  • 320 A rated current for protecting higher-current low-voltage electrical distribution circuits.
  • 50 kA breaking capacity for installations requiring high short-circuit interruption capability.
  • Four-pole (4P) configuration suitable for three-phase electrical distribution systems with a neutral conductor.
  • Ekip Dip LS/I electronic protection for dependable overload and short-circuit fault detection.
  • Selectable short-time or instantaneous short-circuit protection to support electrical protection coordination.
  • Robust ABB Tmax XT5S 400 frame designed for professional low-voltage switchgear applications.
  • Electronic trip technology provides adjustable protection characteristics for different electrical installation requirements.
  • Suitable for ABB Protecta Power distribution systems in commercial and industrial environments.
  • Compact four-pole construction helps optimise installation space within electrical switchboards.
  • Compatible with suitable ABB Tmax XT5 accessories and installation components.

Key Features

  • ABB Protecta Power Devices product range.
  • EPX-XT5S-E1-3204 model designation.
  • 320 A nominal current rating.
  • Four-pole (4P) circuit breaker configuration.
  • 50 kA rated short-circuit breaking capacity.
  • ABB Tmax XT5S 400 moulded case circuit breaker platform.
  • Ekip Dip LS/I electronic trip unit.
  • Long-time (L) overload protection.
  • Selectable short-time (S) or instantaneous (I) short-circuit protection.
  • 190 mm nominal device width for the four-pole XT5S configuration.
  • Electronic protection settings for application-specific circuit protection.
  • Designed for installation in low-voltage electrical distribution assemblies.
  • Suitable for three-phase power distribution applications requiring four-pole switching.
  • Compatible with appropriate ABB Tmax XT5 mechanical and electrical accessories.

Reliable Electronic Circuit Protection for High-Current Distribution Systems

The ABB EPX-XT5S-E1-3204 protects electrical circuits against overloads and short circuits using an electronic trip system. The Ekip Dip LS/I protection unit monitors current conditions and initiates circuit breaker tripping when the configured protection thresholds are exceeded. Long-time protection helps prevent damage caused by sustained overloads, while selectable short-time or instantaneous protection provides the required response to short-circuit faults.

The ABB Tmax XT5S 400 platform combines high-current capability with robust construction and flexible electronic protection settings. Its four-pole configuration makes it suitable for electrical distribution arrangements requiring neutral conductor switching alongside the three phase conductors. Within ABB Protecta Power assemblies, the EPX-XT5S-E1-3204 can protect outgoing feeders and distribution circuits while supporting coordinated electrical protection. For XT5 installations involving larger conductors, an appropriate side cableway extension may be required to accommodate cable routing and termination space.

Typical Applications

  • ABB Protecta Power low-voltage distribution boards.
  • Commercial and industrial main distribution switchboards.
  • Higher-current three-phase outgoing feeder protection.
  • Four-pole electrical distribution circuits incorporating neutral switching.
  • Electrical distribution systems in offices, retail centres and commercial buildings.
  • Industrial manufacturing facilities and production plants.
  • Building services and infrastructure power distribution.
  • Industrial machinery and equipment supply circuit protection.
  • Low-voltage switchgear requiring electronic overload and short-circuit protection.
  • Distribution systems requiring coordinated circuit protection and reliable fault interruption.

Technical Specifications

Product range Protecta Power Devices
Circuit breaker family SACE Tmax XT
Series XT5S
ABB order code 1SDX255167R1
Product type Moulded Case Circuit Breaker (MCCB)
Rated current 320 A
Number of poles 4
Breaking capacity 50 kA
Trip unit Ekip Dip LS/I
Trip technology Electronic
Overload protection Long-time (L)
Short-circuit protection Selectable short-time (S) or instantaneous (I)
Frame designation XT5S 400
Frame current rating 400 A
Nominal device width 190 mm
Rated operational voltage (XT5S platform) Up to 690 V AC
Rated insulation voltage (XT5S platform) 1000 V
Rated impulse withstand voltage (XT5S platform) 8 kV
Applicable circuit breaker standard IEC 60947-2
Installation application Low-voltage electrical distribution
System configuration Three-phase distribution circuits with four-pole switching
Mounting application Switchboard and distribution panel installation
Product group Protecta Power Devices

Frequently Asked Questions

What is the ABB EPX-XT5S-E1-3204 used for?

The ABB EPX-XT5S-E1-3204 is a four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits in commercial and industrial installations.

What is the rated current of the EPX-XT5S-E1-3204?

The circuit breaker has a 320 A rated current and uses the ABB Tmax XT5S 400 frame, making it suitable for appropriately designed higher-current electrical distribution circuits.

What is the breaking capacity of this ABB MCCB?

The EPX-XT5S-E1-3204 has a specified 50 kA breaking capacity. The applicable short-circuit breaking capacity must be checked against the installation voltage and prospective fault current.

What does LS/I electronic protection mean?

LS/I protection provides long-time overload protection (L) together with a selectable short-time (S) or instantaneous (I) short-circuit protection function. The Ekip Dip electronic trip unit allows the relevant protection characteristics to be configured for the electrical installation.

Is the EPX-XT5S-E1-3204 a four-pole circuit breaker?

Yes. The EPX-XT5S-E1-3204 is a four-pole (4P) MCCB suitable for three-phase low-voltage distribution applications requiring a four-pole switching arrangement, including neutral conductor switching where appropriate.

Which ABB circuit breaker series does this product belong to?

The EPX-XT5S-E1-3204 uses the ABB SACE Tmax XT5S 400 moulded case circuit breaker platform and belongs to the ABB Protecta Power Devices range.

What is the difference between LS/I and LSI electronic protection?

LS/I protection provides long-time overload protection with a choice between short-time and instantaneous short-circuit protection. LSI protection includes long-time, short-time and instantaneous protection functions, providing additional flexibility for protection coordination.

Can the EPX-XT5S-E1-3204 be installed in an ABB Protecta Power distribution board?

Yes. The EPX-XT5S-E1-3204 is part of the ABB Protecta Power Devices range and is intended for compatible electrical distribution assemblies. The correct mounting arrangement, electrical connections and accessories must be selected for the specific installation.

What is the difference between the XT5S frame rating and the breaker rated current?

The XT5S 400 frame identifies the circuit breaker platform with a frame current rating of 400 A, while the EPX-XT5S-E1-3204 has a specified rated current of 320 A. The protection settings must be configured according to the connected circuit and installation requirements.

Does the XT5S MCCB require additional installation space for large cables?

Depending on the cable size and distribution board configuration, an ABB Protecta Power side cableway extension may be appropriate for XT5 outgoing devices to provide additional space for cable routing and termination.

Trusted by Electrical Contractors and Distribution System Engineers

ABB SACE Tmax XT moulded case circuit breakers and Protecta Power distribution devices are designed to deliver dependable low-voltage electrical protection in commercial and industrial installations. The EPX-XT5S-E1-3204 combines a robust four-pole XT5S 400 frame, 320 A rated current, 50 kA breaking capacity and electronic LS/I protection to support reliable high-current power distribution and professional switchgear applications.