1SDX255166R1 ABB EPX-XT5S-E1-2504 250A 4-Pole 50kA Electronic LS/I MCCB

1SDX255166R1 ABB EPX-XT5S-E1-2504 250A 4-Pole 50kA Electronic LS/I MCCB

ABB EPX-XT5S-E1-2504 is a 250 A four-pole moulded case circuit breaker with 50 kA breaking capacity and an Ekip Dip electronic LS/I trip unit, designed for configurable overload and short-circuit protection in low-voltage electrical distribution systems.

SKU: 1SDX255166R1Alt SKU: EPX-XT5S-E1-2504MPN: 1SDX255166R1
Price
List Price £1,910.84 ex VAT
Your Price (ex VAT)
£1,910.84
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,910.84
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,910.84

Why Choose the ABB EPX-XT5S-E1-2504 250A 4-Pole MCCB?

The ABB EPX-XT5S-E1-2504 is a high-performance 250 A, 4-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. Featuring a 50 kA breaking capacity and an Ekip Dip electronic LS/I trip unit, this circuit breaker delivers configurable electrical protection for commercial, industrial and infrastructure applications.

As part of the ABB Protecta Power Devices range, the EPX-XT5S-E1-2504 incorporates proven ABB SACE Tmax XT5S400 circuit breaker technology. Its electronic protection system combines long-time overload protection with selectable short-time delayed or instantaneous short-circuit protection, helping safeguard electrical cables, distribution equipment and connected installations against damaging fault conditions.

With a 250 A rated current, four-pole configuration and 50 kA short-circuit breaking capacity, the EPX-XT5S-E1-2504 is suitable for three-phase electrical distribution systems requiring neutral conductor switching. Its 190 mm four-pole device width, fixed mounting configuration and front terminals support integration into ABB Protecta Power distribution assemblies, electrical switchboards and compatible low-voltage switchgear.

Key Advantages

  • 250 A rated current suitable for commercial and industrial low-voltage distribution circuits.
  • 50 kA breaking capacity provides protection against high prospective short-circuit currents at the applicable rated voltage.
  • Four-pole construction supports coordinated switching of three phase conductors and the neutral conductor.
  • Ekip Dip electronic LS/I trip unit provides configurable overload and short-circuit protection.
  • Long-time (L) protection helps protect conductors and connected equipment against sustained overload conditions.
  • Selectable short-time (S) or instantaneous (I) protection supports different short-circuit protection and coordination requirements.
  • Electronic trip technology supports flexible protection settings within appropriately designed distribution systems.
  • ABB SACE Tmax XT5S400 technology combines advanced electronic protection with robust moulded case construction.
  • 190 mm four-pole device width supports integration into compatible electrical distribution assemblies.
  • Fixed mounting with front terminals provides a practical installation arrangement for compatible switchgear.

Key Features

  • ABB Protecta Power Devices electronic trip moulded case circuit breaker.
  • SACE Tmax XT5S400 circuit breaker platform.
  • 250 A rated current for low-voltage electrical distribution protection.
  • 50 kA short-circuit breaking capacity at the specified rated voltage.
  • Four-pole configuration for three-phase and neutral electrical distribution systems.
  • Ekip Dip LS/I electronic trip unit providing overload and short-circuit protection.
  • L protection: Long-time overload protection.
  • S protection: Short-time delayed short-circuit protection when selected.
  • I protection: Instantaneous short-circuit protection when selected.
  • Selectable S/I functionality enables the short-circuit protection mode to be matched to installation requirements.
  • 400 A frame rating within the ABB Tmax XT5S family.
  • 190 mm four-pole device width for compatible distribution assemblies.
  • Fixed circuit breaker construction with front connection terminals.
  • Mechanical operating mechanism with manual switching and automatic protective tripping.
  • Designed in accordance with IEC 60947-2 circuit breaker requirements.

Advanced Four-Pole Electronic LS/I Circuit Protection

The ABB EPX-XT5S-E1-2504 uses an Ekip Dip electronic trip unit to monitor electrical current and initiate protective tripping when overload or short-circuit conditions occur. Its LS/I protection functionality provides long-time overload protection alongside a selectable short-circuit protection mode. Short-time delayed protection can support coordination with downstream protective devices, while instantaneous protection provides rapid tripping during high-current fault conditions.

The ABB SACE Tmax XT5S400 platform combines electronic protection technology with a robust mechanical switching system. Its four-pole construction supports coordinated switching of three phase conductors and the neutral conductor, while the 250 A current rating and 50 kA breaking capacity make it suitable for appropriately designed commercial and industrial distribution installations. The electronic LS/I release offers flexibility when selecting protection characteristics to suit electrical network requirements and protective device coordination.

Typical Applications

  • Commercial and industrial low-voltage distribution boards.
  • ABB Protecta Power electrical distribution assemblies.
  • Three-phase electrical distribution systems with neutral switching requirements.
  • Industrial machinery and equipment supply circuits.
  • Electrical switchboards and industrial control panels.
  • Building services and infrastructure power distribution.
  • Manufacturing facilities and industrial electrical installations.
  • Higher-current sub-distribution circuits requiring electronic overload and short-circuit protection.
  • Electrical distribution systems requiring selectable short-time or instantaneous fault protection.

Technical Specifications

Product range Protecta Power Devices
Series SACE Tmax XT5S
Frame designation XT5S400
ABB order code 1SDX255166R1
Product type Electronic trip moulded case circuit breaker (MCCB)
Rated current 250 A
Number of poles 4
Breaking capacity 50 kA
Trip unit type Ekip Dip electronic LS/I
Overload protection L – long-time protection
Short-circuit protection Selectable S – short-time delayed or I – instantaneous protection
Trip technology Electronic
Frame rated current 400 A
Device width 190 mm
Mounting configuration Fixed
Terminal arrangement Front terminals
Electrical system Three-phase AC distribution with neutral
Operating mechanism Mechanical toggle operation
Application Low-voltage electrical distribution
Applicable standard IEC 60947-2
Product group Protecta Power Devices

Frequently Asked Questions

What is the ABB EPX-XT5S-E1-2504 used for?

The ABB EPX-XT5S-E1-2504 is a four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits using an Ekip Dip electronic LS/I trip unit.

What is the rated current of the EPX-XT5S-E1-2504?

The circuit breaker has a 250 A rated current and belongs to the ABB SACE Tmax XT5S400 frame family, which has a frame current rating of 400 A.

What is the breaking capacity of this ABB MCCB?

The EPX-XT5S-E1-2504 has a specified 50 kA breaking capacity. The applicable operating voltage, prospective fault current and installation conditions must be considered when selecting the circuit breaker.

What does LS/I mean on the ABB EPX-XT5S-E1-2504?

LS/I identifies an electronic protection configuration providing long-time overload protection (L) together with a choice between short-time delayed protection (S) and instantaneous short-circuit protection (I). The selected mode determines how the circuit breaker responds to short-circuit conditions.

What is the advantage of the four-pole configuration?

The four-pole design allows coordinated switching of all three phase conductors and the neutral conductor, making the MCCB suitable for electrical distribution systems requiring four-pole switching and isolation.

Trusted ABB Electronic Circuit Protection Technology

ABB SACE Tmax XT moulded case circuit breakers are engineered to deliver dependable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. The EPX-XT5S-E1-2504 combines a 250 A rated current, four-pole construction, 50 kA breaking capacity and Ekip Dip electronic LS/I protection in a robust XT5S400 frame for reliable electrical distribution applications.