1SDX255158R1 ABB EPX-XT4S-E1-2504 250A 4-Pole 50kA MCCB Ekip LS/I

1SDX255158R1 ABB EPX-XT4S-E1-2504 250A 4-Pole 50kA MCCB Ekip LS/I

ABB EPX-XT4S-E1-2504 is a 250 A four-pole moulded case circuit breaker from the Protecta Power range, featuring a 50 kA breaking capacity at 415 V AC and Ekip LS/I electronic overload and short-circuit protection for commercial and industrial electrical distribution systems.

SKU: 1SDX255158R1Alt SKU: EPX-XT4S-E1-2504MPN: 1SDX255158R1
Price
List Price £1,696.18 ex VAT
Your Price (ex VAT)
£1,696.18
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,696.18
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,696.18

Why Choose the ABB EPX-XT4S-E1-2504 250A 4-Pole MCCB?

The ABB EPX-XT4S-E1-2504 is a high-performance 250 A four-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Featuring a 50 kA breaking capacity and an advanced Ekip LS/I electronic trip unit, this circuit breaker offers reliable protection for commercial, industrial and infrastructure electrical installations.

As part of the ABB Protecta Power Devices range, the EPX-XT4S-E1-2504 incorporates ABB's proven SACE Tmax XT4S250 circuit breaker technology. Its electronic protection system provides adjustable overload protection and selectable short-circuit protection characteristics, enabling electrical engineers to coordinate protective devices and improve the reliability of power distribution networks.

With a rated current of 250 A, a four-pole configuration and a 50 kA short-circuit breaking capacity at 415 V AC, this MCCB is suitable for three-phase electrical distribution systems requiring high-performance circuit protection. Its compact, fixed-mounted design supports integration into ABB Protecta Power distribution assemblies, switchboards and industrial electrical panels. The product is identified by ABB order code 1SDX255158R1.

Key Advantages

  • 250 A rated current for protecting low-voltage electrical distribution circuits.
  • Four-pole configuration suitable for three-phase systems with a neutral conductor.
  • 50 kA breaking capacity at 415 V AC for demanding short-circuit protection requirements.
  • Advanced Ekip LS/I electronic trip unit provides adjustable overload and short-circuit protection.
  • Selectable short-time delayed or instantaneous short-circuit protection supports protection coordination.
  • Based on the established ABB SACE Tmax XT4S250 platform.
  • Compact 140 mm four-pole width supports efficient installation within electrical distribution assemblies.
  • Designed for integration into ABB Protecta Power distribution systems.
  • Electronic protection technology enables more flexible circuit protection settings than conventional fixed-trip devices.
  • Robust construction supports reliable operation in commercial and industrial electrical installations.

Key Features

  • ABB Protecta Power Devices product range.
  • SACE Tmax XT4S250 moulded case circuit breaker platform.
  • 250 A rated current.
  • Four-pole (4P) circuit breaker configuration.
  • 50 kA ultimate short-circuit breaking capacity at 415 V AC.
  • Ekip LS/I electronic protection release.
  • Long-time overload protection (L) for protection against sustained overcurrent.
  • Selectable short-time delayed (S) or instantaneous (I) protection for short-circuit fault conditions.
  • 690 V AC maximum rated operational voltage for the underlying XT4S250 breaker platform.
  • 50/60 Hz rated frequency.
  • Fixed-mounted circuit breaker construction.
  • Suitable for low-voltage switchboards and electrical distribution assemblies.

Reliable Circuit Protection for Low-Voltage Power Distribution

Moulded case circuit breakers such as the ABB EPX-XT4S-E1-2504 protect electrical circuits by automatically interrupting current when overloads or short-circuit faults occur. This helps reduce the risk of damage to cables, switchgear and connected electrical equipment while improving the safety and operational reliability of electrical distribution systems.

The integrated Ekip LS/I electronic trip unit provides long-time overload protection together with a choice of short-time delayed or instantaneous short-circuit protection. Long-time protection responds to sustained overcurrent conditions, while short-circuit protection enables the breaker to disconnect faulted circuits according to the selected protection characteristics.

The LS/I protection arrangement allows the appropriate short-circuit response to be selected for the installation. Short-time delayed protection can support discrimination between upstream and downstream protective devices, while instantaneous protection enables rapid interruption of high fault currents. Unlike an LSI trip unit, LS/I uses a selectable S or I function rather than providing both functions simultaneously.

Built on the ABB SACE Tmax XT4S250 platform, this four-pole MCCB combines high breaking capacity with compact construction. It is particularly suitable for distribution boards and switchgear installations where dependable circuit isolation, adjustable electronic protection and efficient use of enclosure space are important.

Typical Applications

  • ABB Protecta Power electrical distribution assemblies.
  • Commercial building main and sub-distribution boards.
  • Industrial low-voltage switchboards and power distribution panels.
  • Three-phase electrical distribution systems with neutral conductors.
  • Manufacturing facilities and industrial production environments.
  • Electrical infrastructure in warehouses and logistics facilities.
  • Commercial premises, offices and retail developments.
  • Feeder circuit protection in low-voltage distribution networks.
  • Electrical plant rooms and building services installations.
  • Power distribution systems requiring electronic overload and short-circuit protection.

Technical Specifications

Product group Protecta Power Devices
Series SACE Tmax XT
ABB order code 1SDX255158R1
Product type Moulded case circuit breaker (MCCB)
Circuit breaker platform XT4S250
Rated current (In) 250 A
Number of poles 4
Breaking capacity (Icu) at 415 V AC 50 kA
Service breaking capacity (Ics) at 415 V AC 50 kA
Rated operational voltage (Ue) Up to 690 V AC
Rated insulation voltage (Ui) 1,000 V
Rated impulse withstand voltage (Uimp) 8 kV
Rated frequency 50/60 Hz
Trip unit Ekip LS/I
Trip unit technology Electronic
Overload protection Long-time (L)
Short-circuit protection Selectable short-time delayed (S) or instantaneous (I)
Short-circuit performance class S
Mounting type Fixed-mounted circuit breaker
Four-pole device width 140 mm
Application Low-voltage power distribution and circuit protection
Applicable circuit breaker standard IEC 60947-2

Frequently Asked Questions

What is the ABB EPX-XT4S-E1-2504 used for?

The ABB EPX-XT4S-E1-2504 is a four-pole moulded case circuit breaker used to protect low-voltage electrical distribution circuits against overloads and short circuits. It is designed for commercial and industrial switchboards, distribution assemblies and electrical infrastructure.

What is the rated current and breaking capacity of this MCCB?

The circuit breaker has a 250 A rated current and a 50 kA short-circuit breaking capacity at 415 V AC, making it suitable for electrical distribution systems requiring high fault-current interruption capability.

What does the Ekip LS/I electronic trip unit provide?

The Ekip LS/I electronic trip unit provides long-time overload protection (L) and selectable short-time delayed (S) or instantaneous (I) short-circuit protection. This enables protection settings to be adapted to the requirements of the electrical installation.

Is the ABB EPX-XT4S-E1-2504 a four-pole circuit breaker?

Yes. The EPX-XT4S-E1-2504 is a four-pole (4P) MCCB designed for applications requiring four-pole circuit switching and protection, including suitable three-phase distribution systems with a neutral conductor.

What is the ABB order code for the EPX-XT4S-E1-2504?

The ABB Protecta Power order code is 1SDX255158R1. The corresponding product reference is EPX-XT4S-E1-2504, identifying the 250 A, four-pole, 50 kA MCCB with Ekip LS/I electronic protection.

Trusted by Electrical Engineers and Distribution System Designers

ABB SACE Tmax XT moulded case circuit breakers provide dependable protection for modern low-voltage electrical installations. The ABB EPX-XT4S-E1-2504 combines a 250 A current rating, four-pole construction, 50 kA breaking capacity and Ekip LS/I electronic protection, making it a practical solution for reliable circuit protection in ABB Protecta Power distribution systems.