1SDX255157R1 ABB EPX-XT4S-E1-1604 160A 4-Pole 50kA MCCB LS/I

1SDX255157R1 ABB EPX-XT4S-E1-1604 160A 4-Pole 50kA MCCB LS/I

ABB EPX-XT4S-E1-1604 is a 160 A four-pole Tmax XT4S moulded case circuit breaker with 50 kA short-circuit breaking capacity at 415 V AC and Ekip Dip LS/I electronic protection for industrial and commercial low-voltage electrical distribution systems.

SKU: 1SDX255157R1Alt SKU: EPX-XT4S-E1-1604MPN: 1SDX255157R1
Price
List Price £1,372.73 ex VAT
Your Price (ex VAT)
£1,372.73
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,372.73
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,372.73

Why Choose the ABB EPX-XT4S-E1-1604 160A 4-Pole 50kA MCCB?

The ABB EPX-XT4S-E1-1604 is a high-performance 160 A four-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in industrial and commercial low-voltage electrical distribution systems. As part of the ABB Protecta Power Devices range, incorporating the advanced ABB Tmax XT4S circuit breaker platform, it delivers dependable electrical protection for distribution boards, switchgear assemblies and power distribution installations.

This circuit breaker features an ABB Ekip Dip LS/I electronic trip unit, providing long-time overload protection together with selectable short-time or instantaneous short-circuit protection. The electronic trip technology supports accurate fault detection and dependable circuit interruption, helping protect electrical cables, distribution equipment and connected loads against potentially damaging overcurrent conditions.

With a 160 A rated current, four-pole configuration and 50 kA short-circuit breaking capacity at 415 V AC, the EPX-XT4S-E1-1604 is suitable for demanding three-phase electrical distribution applications requiring neutral-pole switching. Its compact 140 mm four-pole XT4S format enables efficient integration into electrical distribution panels and switchboards.

Key Advantages

  • Reliable 160 A moulded case circuit breaker for industrial and commercial electrical distribution.
  • Four-pole (4P) configuration suitable for three-phase systems requiring neutral-pole switching.
  • 50 kA short-circuit breaking capacity at 415 V AC for demanding low-voltage installations.
  • ABB Ekip Dip LS/I electronic protection for effective overload and short-circuit fault management.
  • Selectable short-time or instantaneous short-circuit protection characteristics.
  • Compact ABB Tmax XT4S breaker platform for efficient switchboard integration.
  • Electronic trip technology supports consistent protection performance and electrical system reliability.
  • Suitable for integration into ABB Protecta Power distribution assemblies.
  • Designed to help protect electrical infrastructure and connected equipment against damaging overcurrent conditions.

Key Features

  • ABB Protecta Power Devices range.
  • ABB Tmax XT4S160 moulded case circuit breaker platform.
  • 160 A rated current.
  • Four-pole (4P) configuration.
  • 50 kA rated ultimate short-circuit breaking capacity at 415 V AC.
  • ABB Ekip Dip LS/I electronic trip unit.
  • Long-time overload protection (L).
  • Selectable short-time (S) or instantaneous (I) short-circuit protection.
  • 690 V AC maximum rated operational voltage for the XT4S160 breaker platform.
  • 50/60 Hz rated frequency.
  • Automatic circuit interruption under applicable overload and short-circuit fault conditions.
  • Compact 140 mm four-pole breaker width.
  • Manual switching mechanism with automatic protective tripping.
  • Suitable for low-voltage distribution boards and switchgear assemblies.
  • ABB manufacturer order code 1SDX255157R1.

Reliable Four-Pole Circuit Protection for Electrical Distribution Systems

Moulded case circuit breakers such as the ABB EPX-XT4S-E1-1604 are essential components in modern low-voltage electrical distribution systems. They protect electrical circuits against excessive current caused by overloads and short circuits, automatically interrupting the supply when fault conditions exceed the configured protection thresholds. This helps safeguard cables, switchgear and connected electrical equipment while supporting reliable electrical system operation.

The ABB Tmax XT4S160 platform combines compact construction with advanced electronic protection technology for demanding industrial and commercial installations. Its Ekip Dip LS/I trip unit provides long-time overload protection and allows selection between short-time and instantaneous short-circuit protection characteristics. The four-pole arrangement supports three-phase distribution systems where neutral-pole switching is required, subject to the installation design and applicable electrical standards.

Typical Applications

  • Industrial low-voltage electrical distribution boards.
  • Commercial building power distribution systems.
  • Three-phase and neutral electrical feeder circuits.
  • ABB Protecta Power distribution assemblies.
  • Main and sub-distribution switchboards.
  • Industrial machinery supply circuit protection.
  • Manufacturing facilities and production plants.
  • Building services and electrical infrastructure.
  • Electrical control panels and automation installations.
  • OEM power distribution and panel-building applications.

Technical Specifications

Product range Protecta Power Devices
Series Tmax XT
Breaker platform XT4S160
ABB order code 1SDX255157R1
Product type Moulded case circuit breaker (MCCB)
Rated current 160 A
Number of poles 4P (four-pole)
Rated ultimate short-circuit breaking capacity (Icu) 50 kA at 415 V AC
Rated service short-circuit breaking capacity (Ics) 50 kA at 415 V AC
Rated operational voltage (Ue) Up to 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Rated frequency 50/60 Hz
Trip unit technology Electronic
Trip unit ABB Ekip Dip LS/I
Overload protection Long-time protection (L)
Short-circuit protection Selectable short-time (S) or instantaneous (I)
Short-circuit performance level S
Breaker construction Moulded case
Operating mechanism Manual switching with automatic protective tripping
Width 140 mm
Applicable standard IEC 60947-2
Application Low-voltage electrical distribution and circuit protection
Installation Electrical distribution boards and switchgear assemblies

Frequently Asked Questions

What is the ABB EPX-XT4S-E1-1604 used for?

The ABB EPX-XT4S-E1-1604 is a four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits in industrial and commercial installations.

What is the rated current of the EPX-XT4S-E1-1604?

The circuit breaker has a 160 A rated current, making it suitable for appropriately designed low-voltage electrical distribution circuits requiring 160 A circuit protection.

What is the short-circuit breaking capacity of this MCCB?

The EPX-XT4S-E1-1604 has a 50 kA rated ultimate short-circuit breaking capacity at 415 V AC, providing high fault-current interruption capability for suitable low-voltage electrical distribution applications.

What does Ekip LS/I electronic protection mean?

ABB Ekip LS/I electronic protection provides long-time overload protection (L) together with a selectable short-time (S) or instantaneous (I) short-circuit protection characteristic. This enables the breaker to respond to sustained overloads and short-circuit faults according to its configured protection settings.

Where is the ABB EPX-XT4S-E1-1604 typically installed?

This four-pole MCCB is typically installed in electrical distribution boards, industrial switchboards and low-voltage switchgear assemblies, including suitable ABB Protecta Power distribution systems requiring three-phase and neutral switching.

Trusted by Electrical Engineers and Industrial Panel Builders Worldwide

ABB Tmax XT moulded case circuit breakers are widely used by electrical engineers, switchgear manufacturers and industrial panel builders to provide dependable overload and short-circuit protection in modern power distribution systems. The ABB EPX-XT4S-E1-1604 combines a 160 A current rating, four-pole construction, 50 kA breaking capacity and Ekip Dip LS/I electronic protection in a compact breaker designed for reliable industrial and commercial electrical distribution.