ABB EPX-XT4S-E1-0404 is a 40 A four-pole moulded case circuit breaker with 50 kA breaking capacity at 415 V AC and an Ekip electronic LS/I trip unit providing long-time overload protection with selectable short-time delayed or instantaneous short-circuit protection for commercial and industrial low-voltage distribution systems.
£1,372.60
The ABB EPX-XT4S-E1-0404 is a high-performance 40 A four-pole moulded case circuit breaker (MCCB) designed to provide dependable electrical protection in commercial and industrial low-voltage distribution systems. Featuring a 50 kA short-circuit breaking capacity and an ABB Ekip electronic LS/I trip unit, this circuit breaker offers advanced overload and short-circuit protection. It forms part of the ABB Protecta Power Devices range and uses the established ABB SACE Tmax XT4S160 platform.
Unlike conventional thermal-magnetic MCCBs, the EPX-XT4S-E1-0404 incorporates an electronic protection release for greater flexibility in configuring circuit protection. Its LS/I functionality provides long-time overload protection (L) together with a selectable short-time delayed (S) or instantaneous (I) short-circuit protection function. This allows electrical designers to select a protection characteristic appropriate to the installation and its coordination requirements.
With a 40 A rated current, four-pole (4P) configuration and 50 kA breaking capacity, the ABB EPX-XT4S-E1-0404 is suitable for appropriately designed outgoing circuits in distribution boards, commercial buildings and industrial electrical installations. Its compact 140 mm four-pole format supports efficient integration into compatible ABB Protecta Power assemblies. The product is identified by ABB order code 1SDX255154R1.
The ABB EPX-XT4S-E1-0404 uses an electronic trip unit to monitor circuit current and initiate protective tripping when an overload or short-circuit condition exceeds the configured protection thresholds. Electronic protection provides greater flexibility than traditional thermal-magnetic releases and is particularly valuable in distribution systems where protection settings and coordination require careful consideration.
The long-time (L) protection function responds to sustained overload conditions. This helps protect electrical cables and connected equipment from excessive heating caused by current flowing above the permissible circuit loading for an extended period. The long-time protection settings should be selected according to the cable capacity, installation conditions and connected load.
The short-time (S) protection function provides delayed short-circuit tripping. Where supported by the overall protection design, a short delay can assist with discrimination between upstream and downstream protective devices, allowing the device nearest a fault to operate first.
The alternative instantaneous (I) protection function provides rapid tripping when a sufficiently high short-circuit current is detected. This helps limit the duration of severe electrical faults and protect the installation against the effects of excessive fault current. With the Ekip LS/I release, the short-time and instantaneous characteristics are selectable alternatives rather than three simultaneously active L, S and I functions.
The four-pole configuration enables simultaneous switching of three phase conductors and the neutral conductor. This makes the EPX-XT4S-E1-0404 suitable for appropriately designed three-phase distribution systems where four-pole switching or isolation is required. The neutral protection arrangement and settings must be verified against the specific circuit breaker configuration and installation requirements.
The XT4S160 platform combines a compact moulded case design with the flexibility of electronic protection. With a 40 A rated current and 50 kA breaking capacity at 415 V AC, this MCCB is suitable for circuits requiring relatively modest continuous current capacity but substantial short-circuit interruption capability. Correct selection must account for prospective fault current, operating voltage, cable ratings and coordination with other protective devices.
| Product group | Protecta Power Devices |
|---|---|
| Series | SACE Tmax XT4S |
| Circuit breaker platform | XT4S160 |
| ABB order code | 1SDX255154R1 |
| Corresponding ABB circuit breaker reference | 1SDA068491R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 40 A |
| Number of poles | 4 |
| Pole configuration | Four-pole (3-phase + neutral) |
| Short-circuit breaking capacity (Icu) | 50 kA at 415 V AC |
| Trip unit technology | Electronic |
| Trip unit type | ABB Ekip DIP LS/I |
| Long-time protection (L) | Electronic overload protection |
| Short-time protection (S) | Selectable delayed short-circuit protection |
| Instantaneous protection (I) | Selectable instantaneous short-circuit protection |
| Protection configuration | L with selectable S or I function |
| Frame family | XT4S160 |
| Frame current class | 160 A |
| Four-pole device width | 140 mm |
| Mounting arrangement | Fixed installation |
| Terminal arrangement | Front terminals |
| Operating mechanism | Manual lever with automatic protective tripping |
| Electrical system | Low-voltage AC distribution |
| Application | Commercial and industrial electrical circuit protection |
| Installation type | Compatible electrical distribution boards and switchgear assemblies |
| Product construction | Moulded case circuit breaker |
The ABB EPX-XT4S-E1-0404 is a four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It uses an electronic LS/I trip unit and is suitable for commercial and industrial installations, including compatible ABB Protecta Power distribution boards.
The circuit breaker has a rated current of 40 A and uses the 160 A XT4S frame class. The 160 A designation identifies the circuit breaker frame size, not the rated current of this particular electronic trip unit.
The ABB EPX-XT4S-E1-0404 has a specified 50 kA short-circuit breaking capacity at 415 V AC. Suitability must be checked against the installation's operating voltage and prospective short-circuit current because breaking capacity can vary with voltage.
LS/I identifies the electronic protection functions. L provides long-time overload protection, while the user can select either S for short-time delayed short-circuit protection or I for instantaneous short-circuit protection. This differs from an LSI release, which provides all three protection characteristics.
No. The EPX-XT4S-E1-0404 uses an ABB Ekip electronic LS/I trip unit rather than a conventional thermal-magnetic (TMA) release. Electronic protection offers configurable overload and short-circuit protection characteristics for appropriately designed electrical installations.
Electronic LS/I protection allows the circuit breaker to provide long-time overload protection together with a selectable short-time delayed or instantaneous short-circuit response. This flexibility can help electrical designers coordinate protective devices and choose a tripping characteristic suited to the installation.
The ABB Protecta Power manufacturer order code is 1SDX255154R1. The corresponding ABB XT4S160 electronic circuit breaker reference is 1SDA068491R1. The product reference EPX-XT4S-E1-0404 identifies the 40 A, four-pole, 50 kA electronic LS/I MCCB.
The product belongs to the ABB SACE Tmax XT4S series and uses the XT4S160 circuit breaker platform. This is a 160 A frame-class MCCB fitted with a 40 A electronic LS/I release.
The ABB EPX-XT4S-E1-0404 uses the 140 mm wide four-pole XT4S format. This compact construction supports efficient integration into compatible ABB Protecta Power distribution boards and low-voltage switchgear assemblies.
This MCCB is typically installed within compatible commercial distribution boards, industrial electrical panels and low-voltage switchgear assemblies. It is particularly useful where a 40 A circuit requires electronic protection and a high short-circuit breaking capacity.
ABB is an established manufacturer of electrical protection and power distribution equipment. The ABB Protecta Power Devices range, including the EPX-XT4S-E1-0404 electronic LS/I MCCB, provides electrical contractors, panel builders and facilities engineers with flexible circuit protection solutions for commercial and industrial low-voltage distribution systems.