Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB EPX-XT4S-E1-2503 is a 250 A three-pole 50 kA moulded case circuit breaker from the Protecta Power Devices range, featuring electronic LS/I overload and selectable short-time or instantaneous short-circuit protection for low-voltage three-phase electrical distribution systems.
£1,304.65
The ABB EPX-XT4S-E1-2503 is a high-performance 250 A three-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker combines the established ABB SACE Tmax XT4S platform with electronic LS/I protection and a specified 50 kA short-circuit breaking capacity.
Featuring an electronic LS/I protection arrangement, the EPX-XT4S-E1-2503 provides long-time overload protection together with selectable short-time or instantaneous short-circuit protection characteristics. Unlike conventional thermal-magnetic circuit breakers, electronic trip technology uses electronic current monitoring to determine when protective operation is required. This enables engineers to configure protection characteristics according to the supported trip unit settings and the requirements of the electrical installation.
With its 250 A rated current, three-pole configuration and 50 kA breaking capacity, this MCCB is suitable for appropriately designed three-phase distribution feeders, industrial switchboards and commercial electrical installations. Its ABB SACE Tmax XT4S construction supports integration into compatible ABB Protecta Power distribution assemblies, making it a practical solution for electrical contractors, panel builders, consulting engineers and industrial maintenance professionals.
The ABB EPX-XT4S-E1-2503 provides dependable circuit protection through electronic current monitoring and configurable protective functions. Its long-time protection function (L) responds to sustained overload conditions according to the selected time-current characteristics, helping reduce the risk of excessive heating in cables, busbars, terminals and connected equipment. This makes the breaker suitable for appropriately engineered electrical distribution systems where accurate protection coordination is important.
The LS/I protection arrangement provides a choice between short-time and instantaneous short-circuit protection characteristics. When the short-time function (S) is selected, the trip unit can introduce an intentional delay according to its supported settings, potentially assisting discrimination with downstream protective devices. When the instantaneous function (I) is selected, the breaker responds to sufficiently high short-circuit currents without intentional time delay. The exact protection thresholds, adjustment ranges and operating characteristics must be confirmed from ABB documentation for the supplied trip unit.
The ABB SACE Tmax XT4S platform combines electronic protection technology with a specified 50 kA short-circuit breaking capacity, providing a robust solution for appropriately designed commercial and industrial electrical installations. Its three-pole configuration enables coordinated switching and protection of three-phase circuits, while compatibility with suitable ABB Protecta Power assemblies supports efficient switchboard construction. Engineers should verify the rated operating voltage, prospective fault current, conductor capacity, protection settings and discrimination requirements before installation and commissioning.
| Product group | Protecta Power Devices |
|---|---|
| Product family | SACE Tmax XT |
| Product series | XT4S |
| Product model | EPX-XT4S-E1-2503 |
| ABB order code | 1SDX255152R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Frame designation | XT4S 250 |
| Frame current class | 250 A |
| Rated current (In) | 250 A |
| Number of poles | 3 |
| Specified short-circuit breaking capacity | 50 kA |
| Trip unit technology | Electronic |
| Protection designation | LS/I |
| Long-time protection (L) | Electronic overload protection |
| Short-time protection (S) | Short-circuit protection with time-delay characteristics when selected |
| Instantaneous protection (I) | Short-circuit protection without intentional time delay when selected |
| Protection mode | L with selectable S or I |
| Protection adjustment | According to the supplied electronic trip unit configuration |
| Electrical system | Low-voltage AC distribution |
| Phase configuration | Three-phase |
| Switching configuration | Three-pole |
| Operating method | Manual circuit breaker operation |
| Primary protection functions | Overload and short-circuit protection |
| Additional function | Circuit switching and isolation in accordance with manufacturer requirements |
| Product family standard | IEC/EN 60947-2 |
The ABB EPX-XT4S-E1-2503 is a 250 A three-pole electronic moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It features LS/I protection and is suitable for compatible ABB Protecta Power distribution boards and commercial or industrial electrical panels.
The EPX-XT4S-E1-2503 has a 250 A rated current. This rating should be considered alongside the selected long-time protection settings, conductor current-carrying capacity, installation conditions and applicable derating requirements.
The EPX-XT4S-E1-2503 has a specified 50 kA short-circuit breaking capacity. The applicable rated operating voltage and manufacturer short-circuit performance conditions must be verified against the prospective fault current at the installation location.
LS/I identifies an electronic protection arrangement providing long-time overload protection (L) together with selectable short-time (S) or instantaneous (I) short-circuit protection. The selected function determines the short-circuit response characteristics supported by the trip unit.
LS/I protection provides long-time overload protection with a selectable short-time or instantaneous short-circuit function. LSI protection provides long-time, short-time and instantaneous protection functions within the trip unit configuration. The available settings and operating characteristics should be checked against the manufacturer's technical documentation.
Electronic LS/I trip units provide protection adjustment facilities according to their specific configuration. The available long-time, short-time and instantaneous settings for the EPX-XT4S-E1-2503 should be confirmed from the supplied device and ABB technical documentation before commissioning.
Yes. The EPX-XT4S-E1-2503 has a three-pole configuration designed for coordinated switching and protection of three phase conductors. It is suitable for appropriately designed three-phase low-voltage electrical distribution circuits where neutral switching through the breaker is not required.
XT4N and XT4S identify different short-circuit performance versions within the ABB SACE Tmax XT4 family. The corresponding ABB Protecta Power XT4N devices are specified at 36 kA, while XT4S versions are specified at 50 kA. Selection should be based on the prospective fault current and applicable operating voltage.
ABB SACE Tmax XT moulded case circuit breakers combine established electrical protection technology with electronic trip functionality and substantial short-circuit interruption capability, supporting dependable commercial and industrial low-voltage distribution system design.