1SDX255151R1 ABB EPX-XT4S-E1-1603 160A 3-Pole 50kA LS/I Electronic MCCB

1SDX255151R1 ABB EPX-XT4S-E1-1603 160A 3-Pole 50kA LS/I Electronic MCCB

ABB EPX-XT4S-E1-1603 is a 160 A three-pole 50 kA moulded case circuit breaker from the Protecta Power Devices range, featuring electronic LS/I overload and selectable short-time or instantaneous short-circuit protection for low-voltage electrical distribution systems.

SKU: 1SDX255151R1Alt SKU: EPX-XT4S-E1-1603MPN: 1SDX255151R1
Price
List Price £1,029.75 ex VAT
Your Price (ex VAT)
£1,029.75
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,029.75
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,029.75

Why Choose the ABB EPX-XT4S-E1-1603 160A 3-Pole 50kA MCCB?

The ABB EPX-XT4S-E1-1603 is a high-performance 160 A three-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker combines the established ABB SACE Tmax XT4S platform with electronic LS/I protection and a specified 50 kA short-circuit breaking capacity.

Unlike conventional thermal-magnetic circuit breakers, the EPX-XT4S-E1-1603 incorporates an electronic protection trip unit offering long-time overload protection and selectable short-time or instantaneous short-circuit protection functions. The LS/I protection designation identifies a configuration providing long-time protection (L) together with a selectable short-time (S) or instantaneous (I) protection characteristic. This enables electrical engineers to select appropriate protection behaviour according to circuit requirements and the settings supported by the installed trip unit.

With a 160 A rated current, three-pole configuration and 50 kA breaking capacity, this MCCB is suitable for protecting three-phase outgoing feeders, sub-distribution circuits and appropriately rated equipment supplies. Its ABB Tmax XT4S construction supports integration into compatible ABB Protecta Power distribution assemblies, making it a practical solution for electrical contractors, panel builders, consulting engineers and industrial maintenance professionals.

Key Advantages

  • 160 A rated current: Suitable for protecting appropriately designed three-phase low-voltage electrical distribution circuits.
  • Three-pole construction: Provides coordinated switching and protection of three phase conductors.
  • 50 kA breaking capacity: Offers substantial short-circuit interruption capability under the applicable rated conditions.
  • Electronic LS/I protection: Provides electronic overload protection with selectable short-time or instantaneous short-circuit protection characteristics.
  • Long-time overload protection: Helps protect cables and connected electrical equipment against sustained excessive current.
  • Selectable short-circuit protection: Allows the supported short-time or instantaneous protection mode to be selected according to application requirements.
  • Electronic current sensing: Uses electronic trip technology to monitor current and initiate protective operation.
  • Protection coordination: Supports the design of appropriately coordinated upstream and downstream protective arrangements.
  • ABB SACE Tmax XT4S platform: Uses established ABB circuit breaker technology for dependable electrical distribution protection.
  • Protecta Power integration: Intended for installation in compatible ABB Protecta Power distribution boards.
  • Manual switching capability: Supports circuit operation and isolation procedures in accordance with manufacturer requirements.
  • Robust moulded case construction: Suitable for commercial and industrial electrical distribution environments.
  • Versatile applications: Suitable for outgoing feeders, distribution boards, industrial switchgear and equipment supply circuits.

Key Features

  • Manufacturer: ABB.
  • Product group: Protecta Power Devices.
  • Product model: EPX-XT4S-E1-1603.
  • ABB order code: 1SDX255151R1.
  • Circuit breaker family: ABB SACE Tmax XT.
  • Frame series: XT4.
  • Performance designation: XT4S.
  • Rated current: 160 A.
  • Number of poles: 3.
  • Specified short-circuit breaking capacity: 50 kA.
  • Trip technology: Electronic.
  • Protection designation: LS/I.
  • Long-time protection (L): Overload protection using an electronic trip function.
  • Short-time protection (S): Short-circuit protection with a time-delay characteristic when the S function is selected.
  • Instantaneous protection (I): Short-circuit protection without intentional time delay when the I function is selected.
  • Protection configuration: Long-time protection with selectable S or I functionality.
  • Three-pole switching: Coordinated operation of three phase conductors.
  • Operating mechanism: Manual circuit breaker switching mechanism.
  • Trip indication: Mechanical indication of circuit breaker operating status.
  • Accessory compatibility: Supports appropriately selected ABB Tmax XT4 mounting, connection and operating accessories.
  • Product family standard: IEC/EN 60947-2.

Reliable LS/I Electronic Protection for Three-Phase Electrical Distribution

The ABB EPX-XT4S-E1-1603 provides electrical circuit protection using an electronic trip unit designed to monitor current and respond to overload and short-circuit conditions. The long-time protection function (L) is intended to protect electrical conductors and connected equipment against sustained excessive current. By applying an appropriate time-current characteristic, this function helps reduce the risk of overheating while accommodating normal operating conditions within the selected protection settings.

The LS/I protection arrangement provides a choice between short-time and instantaneous short-circuit protection characteristics. When the short-time function (S) is selected, the trip unit can apply an intentional delay according to its supported settings, which may assist protection coordination with downstream devices. When the instantaneous function (I) is selected, the breaker responds to sufficiently high short-circuit currents without intentional time delay. The precise adjustment ranges, operating thresholds and available selection arrangements should be confirmed from the manufacturer's documentation for the supplied electronic trip unit.

The ABB SACE Tmax XT4S platform combines electronic protection technology with a specified 50 kA short-circuit breaking capacity, providing a practical solution for appropriately engineered electrical distribution systems. Its three-pole configuration supports coordinated protection of three-phase circuits, while its compatibility with ABB Protecta Power assemblies helps simplify distribution board design and installation. Electrical engineers should verify the operating voltage, prospective fault current, conductor ratings, protection settings and discrimination requirements before commissioning.

Typical Applications

  • ABB Protecta Power distribution boards: Protection of compatible 160 A three-pole outgoing circuits.
  • Commercial electrical distribution: Circuit protection in offices, retail premises and commercial buildings.
  • Industrial switchboards: Electronic overload and short-circuit protection for appropriately rated three-phase feeders.
  • Main and sub-distribution boards: Protection of outgoing circuits requiring a 160 A electronic MCCB.
  • Electrical control panels: Protection of suitably designed three-phase equipment supply circuits.
  • Building services installations: Electrical distribution for ventilation, heating, cooling and mechanical plant.
  • Manufacturing facilities: Feeder protection for industrial electrical equipment and distribution circuits.
  • Warehouses and logistics centres: Protection of three-phase low-voltage electrical distribution systems.
  • Coordinated protection systems: Applications requiring selectable short-time or instantaneous short-circuit protection characteristics.
  • High-fault-level installations: Circuits requiring 50 kA short-circuit interruption capability at the applicable operating voltage.
  • Electrical panel building: Distribution assemblies incorporating compatible ABB SACE Tmax XT4 electronic circuit breakers.

Technical Specifications

Product group Protecta Power Devices
Product family SACE Tmax XT
Product series XT4S
Product model EPX-XT4S-E1-1603
ABB order code 1SDX255151R1
Product type Moulded case circuit breaker (MCCB)
Rated current (In) 160 A
Number of poles 3
Specified short-circuit breaking capacity 50 kA
Trip unit technology Electronic
Protection designation LS/I
Long-time protection (L) Electronic overload protection
Short-time protection (S) Short-circuit protection with time-delay characteristics when selected
Instantaneous protection (I) Short-circuit protection without intentional time delay when selected
Protection mode L with selectable S or I
Trip unit adjustment According to the supplied electronic trip unit configuration
Electrical system Low-voltage AC distribution
Phase configuration Three-phase
Switching configuration Three-pole
Operating method Manual circuit breaker operation
Primary protection functions Overload and short-circuit protection
Additional function Circuit switching and isolation in accordance with manufacturer requirements
Product family standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB EPX-XT4S-E1-1603 used for?

The ABB EPX-XT4S-E1-1603 is a 160 A three-pole electronic moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It features LS/I protection and is suitable for compatible ABB Protecta Power distribution boards and commercial or industrial electrical panels.

What is the rated current of the EPX-XT4S-E1-1603?

The EPX-XT4S-E1-1603 has a 160 A rated current. This rating should be considered alongside the selected long-time protection settings, conductor current-carrying capacity and installation conditions.

What is the breaking capacity of this ABB MCCB?

The EPX-XT4S-E1-1603 has a specified 50 kA short-circuit breaking capacity. The applicable rated operating voltage and manufacturer short-circuit performance conditions must be verified against the prospective fault current at the installation location.

What does LS/I electronic protection mean?

LS/I identifies an electronic protection arrangement providing long-time overload protection (L) together with selectable short-time (S) or instantaneous (I) short-circuit protection. The selected function determines the short-circuit response characteristics supported by the trip unit.

What is the difference between LS/I and LSI protection?

LS/I protection provides long-time overload protection with a selectable short-time or instantaneous short-circuit function. LSI protection provides long-time, short-time and instantaneous protection functions within the trip unit configuration. The available settings and operating characteristics should be checked against the manufacturer's technical documentation.

Can the electronic protection settings be adjusted?

Electronic LS/I trip units provide protection adjustment facilities according to their specific configuration. The available long-time, short-time and instantaneous settings for the EPX-XT4S-E1-1603 should be confirmed from the supplied device and ABB technical documentation before commissioning.

Is the EPX-XT4S-E1-1603 suitable for three-phase electrical systems?

Yes. The EPX-XT4S-E1-1603 has a three-pole configuration designed for coordinated switching and protection of three phase conductors. It is suitable for appropriately designed three-phase low-voltage electrical distribution circuits where neutral switching through the breaker is not required.

What is the difference between ABB XT4N and XT4S circuit breakers?

XT4N and XT4S identify different short-circuit performance versions within the ABB SACE Tmax XT4 family. The corresponding ABB Protecta Power XT4N devices are specified at 36 kA, while XT4S versions are specified at 50 kA. Selection should be based on the prospective fault current and applicable operating voltage.

Can the EPX-XT4S-E1-1603 be installed in ABB Protecta Power distribution boards?

Yes. The EPX-XT4S-E1-1603 belongs to the ABB Protecta Power Devices range and is intended for integration into compatible distribution assemblies. The correct XT4 mounting arrangement, electrical connections, enclosure compatibility and electronic protection settings should be verified before installation.

Trusted by Electrical Engineers and Distribution Panel Builders

ABB SACE Tmax XT moulded case circuit breakers combine established electrical protection technology with electronic trip functionality and substantial short-circuit interruption capability, supporting dependable commercial and industrial low-voltage distribution system design.