ABB EPX-XT4S-E1-1003 is a 100 A three-pole moulded case circuit breaker with 50 kA breaking capacity and an Ekip Dip electronic LS/I trip unit, designed for configurable overload and short-circuit protection in low-voltage electrical distribution systems.
£939.61
The ABB EPX-XT4S-E1-1003 is a high-performance 100 A, 3-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. Featuring a 50 kA breaking capacity and an Ekip Dip electronic LS/I trip unit, this circuit breaker delivers configurable electrical protection for commercial, industrial and building services applications.
As part of the ABB Protecta Power Devices range, the EPX-XT4S-E1-1003 incorporates proven ABB SACE Tmax XT4S160 circuit breaker technology. Its electronic protection system provides long-time overload protection together with a choice of short-time delayed or instantaneous short-circuit protection, helping safeguard electrical cables, distribution equipment and connected installations against damaging fault conditions.
With a 100 A rated current, three-pole configuration and 50 kA short-circuit breaking capacity, the EPX-XT4S-E1-1003 is suitable for three-phase electrical distribution circuits requiring dependable electronic protection. Its 110 mm three-pole width supports efficient integration into ABB Protecta Power distribution boards, electrical switchboards and compatible low-voltage switchgear assemblies.
The ABB EPX-XT4S-E1-1003 uses an Ekip Dip electronic trip unit to monitor electrical current and initiate protective tripping when overload or short-circuit conditions occur. Its LS/I protection functionality provides long-time overload protection alongside a selectable short-circuit protection mode. Short-time delayed protection can support coordination with downstream protective devices, while instantaneous protection provides rapid tripping for high-current faults.
The ABB SACE Tmax XT4S160 platform combines electronic protection technology with a robust mechanical switching system. Its three-pole construction provides coordinated protection for three-phase electrical circuits, while the 100 A current rating and 50 kA breaking capacity make it suitable for appropriately designed commercial and industrial distribution installations. The LS/I release provides flexibility when selecting protection characteristics to suit the electrical network and its coordination requirements.
| Product range | Protecta Power Devices |
|---|---|
| Series | SACE Tmax XT4S |
| Frame designation | XT4S160 |
| ABB order code | 1SDX255150R1 |
| Product type | Electronic trip moulded case circuit breaker (MCCB) |
| Rated current | 100 A |
| Number of poles | 3 |
| Breaking capacity | 50 kA |
| Trip unit type | Ekip Dip electronic LS/I |
| Overload protection | L – long-time protection |
| Short-circuit protection | Selectable S – short-time delayed or I – instantaneous protection |
| Trip technology | Electronic |
| Frame rated current | 160 A |
| Device width | 110 mm |
| Mounting configuration | Fixed |
| Terminal arrangement | Front connections |
| Electrical system | Three-phase AC distribution |
| Operating mechanism | Mechanical toggle operation |
| Application | Low-voltage electrical distribution |
| Applicable standard | IEC 60947-2 |
| Product group | Protecta Power Devices |
The ABB EPX-XT4S-E1-1003 is a three-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits using an Ekip Dip electronic LS/I trip unit.
The circuit breaker has a 100 A rated current and belongs to the ABB SACE Tmax XT4S160 frame family, which has a frame current rating of 160 A.
The EPX-XT4S-E1-1003 has a specified 50 kA breaking capacity. The applicable operating voltage, prospective fault current and installation conditions must be considered when selecting the circuit breaker.
LS/I identifies an electronic protection configuration providing long-time overload protection (L) together with a choice between short-time delayed protection (S) and instantaneous short-circuit protection (I). The selected mode determines how the circuit breaker responds to short-circuit conditions.
An LS/I trip unit provides long-time overload protection with a choice between short-time and instantaneous short-circuit protection. An LSI trip unit provides all three protection functions—long-time, short-time and instantaneous—for greater flexibility in protection configuration.
ABB SACE Tmax XT moulded case circuit breakers are engineered to deliver dependable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. The EPX-XT4S-E1-1003 combines a 100 A rated current, three-pole construction, 50 kA breaking capacity and Ekip Dip electronic LS/I protection in a robust XT4S160 frame for reliable electrical distribution applications.