ABB EPX-XT2S-E1-1604 (1SDX255146R1) is a Protecta Power Devices 160 A, 4-pole moulded case circuit breaker with a specified 50 kA breaking capacity and LS/I overcurrent protection for compatible low-voltage electrical distribution systems.
£1,166.59
The ABB EPX-XT2S-E1-1604 is a 160 A, 4-pole moulded case circuit breaker (MCCB) with a specified 50 kA breaking capacity and LS/I protection. Part of the ABB Protecta Power Devices product group, this circuit breaker is designed for low-voltage electrical distribution applications requiring reliable overload and short-circuit protection.
Featuring a 160 A current rating and four-pole configuration, the EPX-XT2S-E1-1604 is suitable for appropriately designed three-phase, four-wire electrical distribution systems. Its LS/I protection arrangement provides long-time, short-time and instantaneous overcurrent protection functions, supporting the selection and coordination of protective devices within compatible electrical installations.
The 50 kA specified breaking capacity makes the EPX-XT2S-E1-1604 relevant to distribution systems where the prospective fault current is within the circuit breaker's applicable verified capability. Identified by ABB order code 1SDX255146R1, this MCCB provides a manufacturer-specific circuit protection solution for electrical contractors, switchboard manufacturers, consulting engineers and maintenance professionals working with compatible ABB Protecta Power equipment.
Industrial and commercial electrical distribution systems require protective devices capable of responding to overloads and short-circuit faults while supporting the coordination of upstream and downstream equipment. The ABB EPX-XT2S-E1-1604 provides a 160 A, four-pole MCCB configuration with LS/I overcurrent protection for appropriately engineered low-voltage installations.
The LS/I protection designation identifies three overcurrent protection functions. Long-time (L) protection addresses sustained overload conditions, short-time (S) protection addresses short-circuit currents over a defined response period, and instantaneous (I) protection provides rapid operation for sufficiently high fault currents. The exact operating characteristics, available adjustments and protection curves must be confirmed using the relevant ABB product documentation.
The four-pole configuration is relevant to three-phase, four-wire electrical systems where the installation design requires a fourth switched pole. The precise neutral-pole switching and protection characteristics must be verified before selection. A four-pole designation does not, by itself, establish whether the neutral pole has identical protection characteristics to the phase poles.
The specified 50 kA breaking capacity is an important consideration when assessing suitability for an electrical distribution installation. The prospective short-circuit current at the point of installation must be established, and the applicable breaking-capacity rating must be checked against the intended operating voltage and ABB technical data. The stated 50 kA value should not be assumed to apply identically at every system voltage.
The EPX-XT2S-E1-1604 should be selected with consideration for conductor sizing, circuit loading, protective device coordination, installation conditions and the requirements of the complete distribution assembly. Applicable requirements of BS EN IEC 60947-2 should be considered for circuit breaker selection, while any relevant BS EN IEC 61439 compliance must be established for the complete verified switchgear assembly rather than assumed from an individual MCCB.
The ABB EPX-XT2S-E1-1604 is a 160 A, 4-pole moulded case circuit breaker designed for low-voltage electrical distribution applications. It provides LS/I overcurrent protection for appropriately designed electrical circuits within compatible distribution assemblies.
The EPX-XT2S-E1-1604 has a specified 160 A rated current. The breaker must be selected according to the circuit load, conductor characteristics, installation conditions and applicable ABB protection characteristics.
The 50 kA rating identifies the specified short-circuit breaking capacity of the MCCB. The applicable breaking capacity must be verified at the intended operating voltage and compared with the prospective fault current at the installation point using ABB technical documentation.
4P indicates a four-pole circuit breaker configuration. LS/I identifies long-time, short-time and instantaneous overcurrent protection functions. The precise neutral-pole characteristics, available settings and protection curves should be confirmed from the applicable ABB product documentation.
The official ABB order code is 1SDX255146R1. The manufacturer product designation is EPX-XT2S-E1-1604, identifying a 160 A, 4-pole, 50 kA MCCB with LS/I protection within the ABB Protecta Power Devices product group.
ABB Protecta Power Devices provide circuit protection solutions for professional low-voltage electrical distribution installations. The EPX-XT2S-E1-1604 combines a 160 A current rating, four-pole construction, specified 50 kA breaking capacity and LS/I overcurrent protection functions, supporting appropriately engineered industrial and commercial power distribution systems.