ABB EPX-XT2S-E1-1004 is a 100 A four-pole moulded case circuit breaker with a specified 50 kA short-circuit breaking capacity and an Ekip LS/I electronic trip unit. Part of the ABB Protecta Power Devices range, it provides adjustable long-time overload protection and selectable short-time delayed or instantaneous short-circuit protection for commercial and industrial low-voltage electrical distribution systems.
£901.19
The ABB EPX-XT2S-E1-1004 is a high-performance 100 A four-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Combining a 50 kA short-circuit breaking capacity with an advanced Ekip LS/I electronic trip unit, this ABB circuit breaker delivers configurable protection for installations requiring substantial fault-current interruption capability and effective protective-device coordination.
Part of the ABB Protecta Power Devices range, the EPX-XT2S-E1-1004 uses the established ABB SACE Tmax XT2S circuit breaker platform. Its electronic trip release provides long-time overload protection (L) together with a choice of short-time delayed (S) or instantaneous (I) short-circuit protection. This flexibility enables electrical designers to select a protection characteristic appropriate to the circuit, the connected equipment and the wider distribution system.
With its 100 A rated current, four-pole configuration and 50 kA breaking capacity, the ABB EPX-XT2S-E1-1004 is suitable for appropriately designed three-phase distribution circuits requiring four-pole switching. Its compact XT2S construction supports integration into compatible ABB Protecta Power distribution boards, commercial switchgear and industrial electrical panels. Identified by ABB order code 1SDX255145R1, this electronic MCCB offers a practical solution for professional electrical installations requiring reliable and adjustable overcurrent protection.
The ABB EPX-XT2S-E1-1004 combines the switching and fault-interruption capabilities of the ABB SACE Tmax XT2S platform with an Ekip LS/I electronic trip unit. This arrangement provides electronic overcurrent monitoring and configurable protection characteristics for electrical distribution circuits. Compared with a conventional thermal-magnetic release, electronic protection offers additional flexibility when selecting overload and short-circuit operating characteristics.
The long-time overload protection function (L) responds to sustained current levels above the selected protection threshold. It uses an inverse-time characteristic, meaning that higher overload currents generally produce shorter operating times. The long-time setting must be selected in accordance with conductor current-carrying capacity, expected circuit loading, installation conditions and the relevant ABB time-current characteristics.
For a 100 A rated electronic MCCB, the rated current identifies the nominal current of the protective configuration. It does not mean that every adjustable overload setting is fixed at 100 A. The available long-time adjustment positions depend on the exact Ekip LS/I release, and the selected protection threshold must be verified during circuit design and commissioning.
The short-time delayed protection function (S) provides short-circuit protection with a defined operating delay. This characteristic can help achieve coordination between upstream and downstream protective devices in suitable electrical distribution systems. By allowing a downstream protective device an opportunity to clear a fault, short-time delayed protection may reduce unnecessary interruption of unaffected circuits. Actual selectivity must be established using the relevant ABB coordination tables and time-current curves.
The alternative instantaneous protection function (I) provides rapid tripping when the detected current reaches the selected short-circuit threshold. This operating mode is appropriate where fast interruption of high fault currents is required. Its setting must take account of prospective short-circuit current, conductor protection, connected equipment and any permissible transient currents associated with the load.
An important feature of the Ekip LS/I trip unit is that the short-circuit protection characteristic is selectable between S and I. The release provides long-time overload protection together with either short-time delayed or instantaneous short-circuit protection. It should not be confused with an Ekip LSI trip unit, which provides separate L, S and I protection functions. Choosing between LS/I and LSI depends on the protection and coordination requirements of the installation.
The XT2S breaking-capacity classification provides a specified 50 kA short-circuit breaking capacity, making this MCCB suitable for consideration in installations with substantial prospective fault currents. The S classification offers a higher specified breaking capacity than corresponding XT2N configurations under the relevant reference conditions. However, the circuit breaker's actual short-circuit interruption capability must be checked at the intended operating voltage.
When selecting the EPX-XT2S-E1-1004, electrical designers must distinguish between the ultimate short-circuit breaking capacity (Icu) and the service short-circuit breaking capacity (Ics). These ratings describe different aspects of short-circuit interruption performance under IEC/EN 60947-2. The appropriate voltage-dependent values should be confirmed against ABB's technical documentation for the exact breaker configuration rather than assuming that the headline 50 kA rating applies under every operating condition.
The four-pole configuration enables coordinated switching of four conductors, typically the three phase conductors and a neutral conductor in an appropriately designed three-phase distribution system. This arrangement is useful where neutral isolation is required alongside phase switching. However, four-pole construction does not automatically establish the neutral conductor's overcurrent sensing or protection settings. The exact neutral arrangement must be checked against ABB's documentation and the applicable electrical installation requirements.
The ABB SACE Tmax XT2 160 A frame platform provides the mechanical foundation for the 100 A electronic protection configuration. Although the XT2 frame family accommodates higher current ratings, the EPX-XT2S-E1-1004 is specifically a 100 A rated protective device. The frame rating must not be confused with the rated current of the installed release or the permissible current-carrying capacity of the protected circuit.
As part of the ABB Protecta Power Devices range, the EPX-XT2S-E1-1004 is designed for integration into compatible distribution assemblies. Its compact four-pole format supports efficient panel layouts, while the electronic trip unit provides protection-setting flexibility for professional electrical applications. Correct mounting, electrical connections, protective settings and coordination with other devices must be confirmed using the manufacturer's installation instructions.
The standard Ekip LS/I electronic trip unit provides overload and short-circuit protection rather than dedicated residual-current or earth-leakage protection. Where earth-leakage protection is required, an appropriately specified additional protective device or compatible arrangement must be provided. Final circuit breaker selection should be supported by fault-level calculations, conductor sizing, protective-device coordination studies and the applicable electrical installation standards.
| Product group | Protecta Power Devices |
|---|---|
| Product reference | EPX-XT2S-E1-1004 |
| ABB order code | 1SDX255145R1 |
| Product category | Moulded case circuit breaker (MCCB) |
| Manufacturer series | SACE Tmax XT2 |
| Protecta Power designation | XT2S |
| Rated current (In) | 100 A |
| Number of poles | 4 |
| Pole configuration | 4P |
| Specified short-circuit breaking capacity | 50 kA |
| Breaking-capacity variant | S |
| Trip unit | Ekip LS/I |
| Trip technology | Electronic overcurrent protection |
| Long-time protection function | L |
| Long-time protection purpose | Overload protection |
| Long-time protection characteristic | Inverse-time |
| Long-time protection settings | Adjustable according to the fitted Ekip release |
| Short-time delayed protection function | S, selectable |
| Instantaneous protection function | I, selectable |
| Short-circuit protection selection | S or I |
| Simultaneous independent S and I functions | Not provided by the LS/I configuration |
| Short-circuit protection settings | According to the selected operating mode and ABB trip-unit data |
| Overcurrent sensing | Electronic |
| Frame family | XT2S |
| XT2 frame platform | 160 A |
| Rated protective current | 100 A |
| Nominal four-pole width | 120 mm |
| Operating mechanism | Manual circuit breaker mechanism |
| Switching arrangement | Four-pole operation |
| Neutral-pole protection | Verify the exact neutral sensing and protection arrangement against ABB documentation |
| Residual-current protection | Not a standard LS/I trip function |
| Applicable circuit breaker standard | IEC/EN 60947-2 |
| Typical application | Commercial and industrial low-voltage electrical distribution |
The ABB EPX-XT2S-E1-1004 is a 100 A four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It uses an Ekip LS/I electronic trip unit and is suitable for compatible commercial and industrial distribution assemblies, including ABB Protecta Power systems.
The EPX-XT2S-E1-1004 has a 100 A rated current. Its electronic long-time overload protection can be configured according to the available Ekip LS/I settings and the requirements of the protected circuit.
The ABB EPX-XT2S-E1-1004 has a specified 50 kA short-circuit breaking capacity. The applicable ultimate and service breaking capacities must be checked against the installation voltage and prospective fault current using ABB's technical documentation.
Ekip LS/I is an ABB electronic trip-unit configuration providing long-time overload protection (L) together with a selectable short-circuit protection characteristic. The short-circuit function can be configured for either short-time delayed protection (S) or instantaneous protection (I).
No. With Ekip LS/I, the short-circuit protection characteristic is selected between S and I. It does not provide independently configurable short-time delayed and instantaneous protection functions simultaneously. A suitable Ekip LSI release should be considered where all three L, S and I functions are required together.
An electronic trip unit uses electronic current sensing to provide configurable protection characteristics. This can offer greater flexibility when selecting overload and short-circuit settings and coordinating protective devices. The exact adjustment options depend on the Ekip release fitted to the circuit breaker.
XT2S and XT2N identify different breaking-capacity variants within the ABB SACE Tmax XT2 range. The XT2S Protecta Power configuration is specified at 50 kA, compared with 36 kA for corresponding XT2N configurations under the relevant reference conditions. The correct selection depends on the installation voltage and prospective short-circuit current.
The four-pole (4P) configuration supports coordinated switching of four conductors, typically three phase conductors and a neutral conductor in a three-phase electrical distribution system. It is useful where neutral isolation is required, subject to the manufacturer's neutral-pole arrangement and applicable electrical regulations.
The standard Ekip LS/I electronic trip unit provides overload and short-circuit protection rather than dedicated residual-current or earth-leakage protection. Where earth-leakage protection is required, an appropriately specified additional protective device or compatible arrangement must be provided.
The 100 A rating identifies the rated current of the installed electronic protection release, while the 160 A frame rating identifies the current rating of the XT2 mechanical platform. The EPX-XT2S-E1-1004 is a 100 A protective device and must not be treated as a 160 A rated circuit breaker.
The ABB manufacturer order code is 1SDX255145R1. The corresponding product reference is EPX-XT2S-E1-1004, identifying the 100 A, four-pole, 50 kA Ekip LS/I electronic MCCB within the ABB Protecta Power Devices range.
The ABB EPX-XT2S-E1-1004 combines a 100 A four-pole configuration, 50 kA short-circuit breaking capacity and configurable Ekip LS/I electronic protection in a compact SACE Tmax XT2S moulded case circuit breaker. Designed for compatible ABB Protecta Power assemblies, it provides dependable long-time overload protection and selectable short-time delayed or instantaneous short-circuit protection for professionally specified commercial and industrial low-voltage electrical distribution systems.