ABB EPX-XT2S-E1-0634 is a 63 A four-pole moulded case circuit breaker with 50 kA short-circuit breaking capacity and an Ekip LS/I electronic trip unit. Part of the ABB Protecta Power Devices range, it provides configurable long-time overload protection and selectable short-time delayed or instantaneous short-circuit protection for commercial and industrial low-voltage electrical distribution systems.
£901.19
The ABB EPX-XT2S-E1-0634 is a high-performance 63 A four-pole moulded case circuit breaker (MCCB) designed for dependable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Combining a 50 kA short-circuit breaking capacity with an advanced ABB Ekip LS/I electronic trip unit, this circuit breaker offers configurable protection for installations where reliable fault interruption and effective protective-device coordination are essential.
Part of the ABB Protecta Power Devices range, the EPX-XT2S-E1-0634 incorporates the established ABB SACE Tmax XT2S circuit breaker platform. Its electronic protection release provides adjustable long-time overload protection (L) together with a choice of short-time delayed (S) or instantaneous (I) short-circuit protection. This LS/I arrangement allows electrical designers to configure the circuit breaker for different protection requirements without relying on a conventional thermal-magnetic trip mechanism.
Featuring a 63 A rated current, four-pole configuration and 50 kA breaking capacity, the ABB EPX-XT2S-E1-0634 is suited to appropriately designed three-phase distribution circuits requiring four-pole switching. Its compact XT2S construction makes it particularly useful in compatible ABB Protecta Power distribution boards, commercial switchgear and industrial electrical panels. Identified by ABB order code 1SDX255144R1, this MCCB delivers advanced electronic circuit protection in a practical, space-efficient format.
The ABB EPX-XT2S-E1-0634 combines the switching and short-circuit interruption capabilities of the ABB SACE Tmax XT2S platform with an Ekip LS/I electronic trip unit. This electronic protection system monitors circuit current and operates the breaker when the selected protection conditions are met. Compared with a conventional thermal-magnetic release, electronic protection provides greater flexibility in setting overload thresholds and choosing the required short-circuit protection characteristic.
The long-time overload protection function (L) protects the connected circuit against sustained overcurrent conditions. It uses an inverse-time operating characteristic, meaning that larger overload currents generally produce shorter tripping times. The long-time protection threshold and associated settings must be selected according to the protected conductors, expected load, installation conditions and the applicable ABB Ekip LS/I trip curves.
The short-time delayed protection function (S) is designed to respond to short-circuit currents using a defined delay characteristic. Where suitable, this can help coordinate the upstream MCCB with downstream protective devices, allowing a downstream device an opportunity to clear a fault before the upstream breaker operates. Successful discrimination depends on the complete protective-device arrangement and must be confirmed using ABB's published coordination data.
The instantaneous protection function (I) provides rapid tripping when the detected current reaches the configured instantaneous threshold. This operating mode is useful where fast interruption of high fault currents is a priority. The threshold must be selected with regard to prospective short-circuit current, conductor protection, equipment characteristics and any permissible transient starting currents.
A key distinction of the Ekip LS/I release is that the short-circuit protection characteristic is selectable between S and I. The device provides long-time overload protection together with either short-time delayed or instantaneous short-circuit protection, depending on its configuration. It should not be described as providing independently adjustable S and I functions simultaneously. Installations requiring both functions together should be assessed for a suitable Ekip LSI configuration.
The XT2S breaking-capacity classification provides a specified 50 kA short-circuit breaking capacity. For the corresponding ABB XT2S IEC breaker, both the rated ultimate breaking capacity (Icu) and rated service breaking capacity (Ics) are 50 kA at 415 V AC. This provides substantial fault-current interruption capability for appropriately designed low-voltage installations, including distribution circuits with relatively high prospective short-circuit currents.
Short-circuit breaking capacity is dependent on operating voltage. For the corresponding XT2S electronic breaker configuration, the rated ultimate breaking capacity is 50 kA across 380–440 V AC, reducing to 36 kA at 500 V AC, 25 kA at 525 V AC and 12 kA at 690 V AC. Electrical designers must confirm the applicable rating for the intended system voltage and ensure that it is adequate for the calculated prospective fault current.
The four-pole construction supports coordinated switching of four conductors, typically three phase conductors and a neutral conductor in an appropriately designed three-phase distribution system. This arrangement can be useful where the installation requires neutral isolation alongside phase switching. However, the presence of four poles does not automatically establish the neutral conductor's protection settings or sensing arrangement. The precise neutral-pole configuration must be confirmed against the manufacturer's documentation.
The ABB SACE Tmax XT2S 160 A frame platform provides the mechanical foundation for the 63 A electronic protection configuration. Although the XT2 frame family supports higher current ratings, the EPX-XT2S-E1-0634 is specifically a 63 A rated protective device. The frame rating must not be confused with the rated current of the installed electronic release or the current-carrying capacity of the protected circuit.
As part of the ABB Protecta Power Devices range, the EPX-XT2S-E1-0634 is designed for integration into compatible distribution assemblies. The fixed-mounted XT2S platform and front-terminal arrangement support installation within suitable electrical panels. Correct mounting accessories, conductor terminations, protection settings and enclosure arrangements must be selected according to ABB's installation instructions.
The standard Ekip LS/I electronic trip unit provides overload and short-circuit protection rather than dedicated residual-current or earth-leakage protection. Where earth-leakage protection is required, a suitable additional protective device or compatible protection arrangement must be specified. Final selection should be supported by fault-level calculations, conductor sizing, protection coordination studies and the applicable electrical installation standards.
| Product group | Protecta Power Devices |
|---|---|
| Product reference | EPX-XT2S-E1-0634 |
| ABB order code | 1SDX255144R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Series | SACE Tmax XT2 / Protecta Power |
| Circuit breaker designation | XT2S |
| Rated current (In) | 63 A |
| Number of poles | 4 |
| Pole configuration | 4P |
| Specified short-circuit breaking capacity | 50 kA |
| Rated ultimate short-circuit breaking capacity (Icu) | 50 kA at 415 V AC for the corresponding XT2S IEC breaker |
| Rated service short-circuit breaking capacity (Ics) | 50 kA at 415 V AC for the corresponding XT2S IEC breaker |
| Breaking-capacity classification | S |
| Trip unit type | Ekip LS/I |
| Trip technology | Electronic overcurrent protection |
| Long-time overload protection | L |
| Short-time delayed short-circuit protection | S, selectable |
| Instantaneous short-circuit protection | I, selectable |
| Short-circuit protection configuration | S or I, according to the selected LS/I mode |
| Long-time protection adjustment | Configurable according to the Ekip LS/I release settings |
| Short-circuit protection adjustment | Configurable according to the selected S or I mode |
| Protection setting interface | Electronic trip-unit adjustment controls |
| Frame family | XT2S |
| Frame rating | 160 A |
| Rated protective current | 63 A |
| Nominal four-pole width | 120 mm |
| Rated operational voltage | Up to 690 V AC |
| Rated insulation voltage (Ui) | 1,000 V |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Rated frequency | 50/60 Hz |
| Current type | AC |
| Rated ultimate breaking capacity at 380–440 V AC | 50 kA for the corresponding XT2S IEC breaker |
| Rated ultimate breaking capacity at 500 V AC | 36 kA for the corresponding XT2S IEC breaker |
| Rated ultimate breaking capacity at 525 V AC | 25 kA for the corresponding XT2S IEC breaker |
| Rated ultimate breaking capacity at 690 V AC | 12 kA for the corresponding XT2S IEC breaker |
| Mounting configuration | Fixed |
| Terminal configuration | Front terminals |
| Operating mechanism | Manual toggle-operated circuit breaker |
| Switching arrangement | Four-pole operation |
| Neutral-pole protection | Verify the exact neutral protection configuration against ABB documentation |
| Applicable circuit breaker standard | IEC/EN 60947-2 |
| Typical application | Low-voltage three-phase electrical distribution |
The ABB EPX-XT2S-E1-0634 is a 63 A four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It uses an Ekip LS/I electronic trip unit and is suitable for compatible commercial and industrial distribution assemblies, including ABB Protecta Power systems.
The EPX-XT2S-E1-0634 has a 63 A rated current. Its electronic long-time overload protection can be configured according to the available trip-unit settings and the requirements of the protected electrical circuit.
The ABB EPX-XT2S-E1-0634 has a specified 50 kA short-circuit breaking capacity. The corresponding XT2S IEC electronic breaker configuration has rated ultimate and service breaking capacities of 50 kA at 415 V AC. The applicable rating must be checked against the installation voltage and prospective fault current.
Ekip LS/I is an ABB electronic trip-unit configuration providing long-time overload protection (L) together with a selectable short-circuit protection characteristic. The short-circuit function can be configured for either short-time delayed protection (S) or instantaneous protection (I).
No. With Ekip LS/I, the short-circuit protection characteristic is selected between S and I. It does not provide independently configurable short-time delayed and instantaneous protection functions simultaneously. A suitable Ekip LSI release should be considered where all three L, S and I functions are required together.
An electronic trip unit provides configurable protection characteristics using electronic current sensing. This can offer greater flexibility when selecting overload and short-circuit settings and coordinating protective devices. The exact adjustment options depend on the Ekip release fitted to the circuit breaker.
XT2S and XT2N identify different breaking-capacity variants within the ABB SACE Tmax XT2 range. Corresponding XT2S configurations provide a 50 kA breaking capacity at 415 V AC, compared with 36 kA for XT2N configurations. The correct selection depends on the installation voltage and prospective short-circuit current.
The four-pole (4P) configuration supports coordinated switching of four conductors, typically three phase conductors and a neutral conductor in a three-phase electrical distribution system. It is useful where neutral isolation is required, subject to the manufacturer's neutral-pole arrangement and applicable electrical regulations.
The standard Ekip LS/I electronic trip unit provides overload and short-circuit protection rather than dedicated residual-current or earth-leakage protection. Where earth-leakage protection is required, an appropriately specified additional protective device or compatible arrangement must be provided.
The 63 A rating identifies the rated current of the installed electronic protection release, while the 160 A frame rating identifies the current rating of the XT2 mechanical platform. The EPX-XT2S-E1-0634 is a 63 A protective device and must not be treated as a 160 A rated circuit breaker.
The ABB manufacturer order code is 1SDX255144R1. The corresponding product reference is EPX-XT2S-E1-0634, identifying the 63 A, four-pole, 50 kA Ekip LS/I electronic MCCB within the ABB Protecta Power Devices range.
The ABB EPX-XT2S-E1-0634 combines a 63 A four-pole configuration, 50 kA short-circuit breaking capacity and configurable Ekip LS/I electronic protection in a compact SACE Tmax XT2S moulded case circuit breaker. Designed for compatible ABB Protecta Power assemblies, it provides dependable overload protection and selectable short-time delayed or instantaneous short-circuit protection for professionally specified commercial and industrial low-voltage electrical distribution systems.