ABB EPX-XT2S-E1-0254 is a 25 A four-pole moulded case circuit breaker with 50 kA short-circuit breaking capacity and an Ekip LS/I electronic trip unit. Part of the ABB Protecta Power Devices range, it provides adjustable long-time overload protection with selectable short-time delayed or instantaneous short-circuit protection for commercial and industrial low-voltage electrical distribution.
£901.19
The ABB EPX-XT2S-E1-0254 is a high-performance 25 A four-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker combines a 50 kA short-circuit breaking capacity with an Ekip LS/I electronic trip unit, delivering flexible protection for three-phase and neutral electrical circuits.
Built around the established ABB SACE Tmax XT2S platform, the EPX-XT2S-E1-0254 incorporates electronic protection technology that allows its operating characteristics to be configured according to the electrical installation. Unlike conventional thermal-magnetic MCCBs, the electronic trip unit provides adjustable protection functions designed to support accurate overload protection and appropriate short-circuit response.
The LS/I protection arrangement provides long-time overload protection (L) together with a selectable short-circuit protection characteristic: short-time delayed protection (S) or instantaneous protection (I). This flexibility allows electrical designers to select a protection strategy suited to the conductor ratings, prospective fault currents and coordination requirements of the distribution system.
Its four-pole (4P) configuration supports coordinated switching of three phase conductors and a neutral conductor where required by the electrical installation design. This makes the circuit breaker particularly useful for appropriately designed three-phase and neutral distribution arrangements in commercial buildings, industrial facilities and electrical distribution assemblies.
With its 25 A rated current, 50 kA breaking capacity and compact 120 mm four-pole width, the ABB EPX-XT2S-E1-0254 offers a versatile circuit protection solution for compatible ABB Protecta Power panelboards. The product is identified by ABB order code 1SDX255143R1, supporting accurate specification, procurement, maintenance and replacement.
The ABB EPX-XT2S-E1-0254 provides advanced electronic protection for low-voltage electrical distribution systems where reliable overload protection, configurable short-circuit response and four-pole switching are required. Its Ekip LS/I electronic trip unit offers greater flexibility than a conventional fixed-characteristic circuit breaker, helping electrical designers match protective performance to the requirements of the installation.
The long-time protection function (L) provides overload protection for the connected electrical circuit. It responds when current exceeds the configured protection threshold for a sufficient period, helping prevent excessive heating of conductors and connected equipment. Correct adjustment of the long-time protection settings is essential to ensuring that the circuit breaker provides suitable protection for the conductor size, installation method and expected operating load.
The short-time protection function (S) provides a delayed response to short-circuit currents when this mode is selected. The delay can be useful in electrical distribution systems where coordination between upstream and downstream protective devices is required. By allowing a downstream device an opportunity to clear a fault first, a correctly designed protection arrangement may reduce unnecessary disconnection of unaffected circuits.
Alternatively, the instantaneous protection function (I) provides rapid operation when the fault current reaches the selected threshold. This mode is suitable where fast fault interruption is the priority and a short-time delay is not required. The appropriate choice depends on the prospective fault current, connected equipment, conductor withstand characteristics and overall protection strategy.
An important distinction is that LS/I protection does not mean that all three L, S and I functions operate independently at the same time. The ABB Ekip LS/I arrangement provides long-time overload protection together with a choice between short-time delayed and instantaneous short-circuit protection. Where independent L, S and I functions are required together, an LSI trip-unit configuration should be considered.
The 25 A rated current makes the EPX-XT2S-E1-0254 suitable for appropriately designed lower-current distribution feeders and outgoing circuits. Its electronic protection settings allow the MCCB to be configured for the application within the manufacturer's specified adjustment limits. This flexibility is particularly valuable where protection coordination must be considered alongside conductor protection and operational continuity.
The four-pole construction is an important feature of this MCCB. Unlike a three-pole circuit breaker, a four-pole device can provide coordinated switching of the neutral conductor alongside the three phase conductors. This may be necessary for certain electrical distribution arrangements, isolation requirements and installation designs. The suitability of neutral switching must be assessed against the earthing system, applicable electrical standards and the specific circuit configuration.
It is also important to distinguish between neutral switching and neutral overcurrent protection. A four-pole circuit breaker includes an additional switched pole, but the protection characteristics of that pole depend on the specific device construction and electronic trip-unit configuration. Electrical designers should verify the manufacturer's neutral pole arrangements and applicable protection characteristics before specifying the MCCB for a particular installation.
The 50 kA short-circuit breaking capacity is a key characteristic of the XT2S platform. Electrical distribution systems can experience prospective short-circuit currents considerably higher than their normal operating currents. The selected MCCB must therefore be capable of interrupting the maximum prospective fault current at its installation point. Breaking-capacity ratings are voltage-dependent, so the applicable ABB technical data should be checked against the actual system operating voltage.
The ABB SACE Tmax XT2S platform combines electronic protection capability with compact mechanical construction. Its 120 mm four-pole width supports efficient integration into compatible electrical distribution assemblies, while the XT2 160 frame family provides a practical solution for professional low-voltage power distribution.
As part of the ABB Protecta Power Devices range, the EPX-XT2S-E1-0254 is intended for installation in compatible panelboards and distribution assemblies using the correct mounting and connection components. Before commissioning, electrical designers and installers should verify the prospective fault current, operating voltage, conductor ratings, electronic trip settings, neutral requirements, discrimination requirements and compatibility with the selected distribution assembly.
| Product group | Protecta Power Devices |
|---|---|
| Product range | Protecta Power |
| Circuit breaker platform | ABB SACE Tmax XT2S |
| ABB order code | 1SDX255143R1 |
| Corresponding ABB XT2S breaker reference | 1SDA067834R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 25 A |
| Number of poles | 4 |
| Electrical configuration | Three-phase and neutral |
| Specified short-circuit breaking capacity | 50 kA |
| Trip unit designation | E1 |
| Trip unit type | Ekip LS/I |
| Protection technology | Electronic |
| Long-time overload protection | L |
| Short-time delayed short-circuit protection | S, selectable |
| Instantaneous short-circuit protection | I, selectable |
| LS/I protection arrangement | Long-time protection with selection between short-time delayed and instantaneous short-circuit protection |
| Protection settings | Adjustable within the manufacturer's specified limits |
| Frame family | XT2 |
| Frame designation | XT2S |
| Frame current class | 160 A |
| Breaking-capacity classification | S |
| Four-pole device width | 120 mm |
| Operating mechanism | Manual switching with automatic electronic protective tripping |
| Applicable circuit breaker standard | IEC 60947-2 |
| Application category | Low-voltage electrical power distribution |
| Mounting application | Compatible electrical distribution assemblies |
| Typical installation | ABB Protecta Power panelboards and compatible distribution equipment |
| Neutral switching | Four-pole configuration; neutral protection characteristics must be confirmed against the applicable ABB documentation |
| Protection coordination | Verify electronic trip settings and selectivity using ABB technical documentation |
The ABB EPX-XT2S-E1-0254 is a four-pole electronic moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for appropriately designed commercial and industrial installations, including compatible ABB Protecta Power distribution assemblies.
The ABB EPX-XT2S-E1-0254 has a 25 A rated current and a specified 50 kA short-circuit breaking capacity. Its suitability must be assessed against the installation's operating voltage, prospective fault current and applicable protection requirements.
LS/I refers to an electronic protection arrangement providing long-time overload protection (L) with a selectable short-circuit protection mode: short-time delayed protection (S) or instantaneous protection (I). The selected mode should be configured according to the electrical installation's protection requirements.
An LS/I trip unit provides long-time overload protection together with a choice between short-time and instantaneous short-circuit protection. An LSI trip unit provides long-time, short-time and instantaneous protection functions independently, offering additional flexibility for protection coordination.
The four-pole configuration allows coordinated switching of three phase conductors and a neutral conductor where required by the electrical installation design. This can be useful in three-phase and neutral distribution systems, subject to the installation's earthing arrangements, neutral protection requirements and applicable electrical standards.
ABB Protecta Power protective devices combine established circuit protection engineering with practical low-voltage distribution solutions. The EPX-XT2S-E1-0254 offers a compact 25 A, four-pole XT2S MCCB configuration with Ekip LS/I electronic protection and a 50 kA breaking capacity, supporting flexible and dependable circuit protection in appropriately designed commercial and industrial electrical installations.