1SDX255142R1 ABB EPX-XT2S-E1-1603 160A 3-Pole 50kA MCCB LS/I

1SDX255142R1 ABB EPX-XT2S-E1-1603 160A 3-Pole 50kA MCCB LS/I

ABB EPX-XT2S-E1-1603 is a 160 A three-pole moulded case circuit breaker with 50 kA short-circuit breaking capacity and an Ekip LS/I electronic trip unit. Part of the ABB Protecta Power Devices range, it provides adjustable long-time overload protection with selectable short-time delayed or instantaneous short-circuit protection for commercial and industrial low-voltage electrical distribution.

SKU: 1SDX255142R1Alt SKU: EPX-XT2S-E1-1603MPN: 1SDX255142R1
Price
List Price £888.88 ex VAT
Your Price (ex VAT)
£888.88
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £888.88
Trade pricing is personalised to your account

Manufacturer Lead Time

£888.88

Why Choose the ABB EPX-XT2S-E1-1603 160A 3-Pole 50kA MCCB?

The ABB EPX-XT2S-E1-1603 is a high-performance 160 A three-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker combines a 50 kA short-circuit breaking capacity with an electronic Ekip LS/I trip unit, offering flexible protection for demanding three-phase electrical installations.

Built around the established ABB SACE Tmax XT2S platform, the EPX-XT2S-E1-1603 incorporates electronic protection technology that allows its operating characteristics to be configured to suit the electrical installation. Unlike conventional thermal-magnetic MCCBs, the electronic trip unit uses electronic sensing and protection logic to provide adjustable overload and short-circuit protection functions.

The LS/I protection arrangement provides long-time overload protection (L) together with a selectable short-circuit protection characteristic: short-time delayed protection (S) or instantaneous protection (I). This enables electrical designers to select an appropriate short-circuit response according to the protection coordination requirements of the distribution system.

With its 160 A rated current, three-pole configuration, 50 kA breaking capacity and compact 100 mm three-pole width, the ABB EPX-XT2S-E1-1603 provides a versatile protection solution for compatible ABB Protecta Power panelboards and electrical distribution assemblies.

The product is identified by ABB order code 1SDX255142R1, supporting accurate specification, procurement, maintenance and replacement.

Key Advantages

  • 160 A rated current for appropriately designed three-phase electrical distribution circuits.
  • Three-pole (3P) configuration for coordinated switching and protection of three-phase conductors.
  • 50 kA short-circuit breaking capacity for installations requiring substantial fault-interruption performance.
  • Electronic Ekip LS/I trip unit provides configurable overload and short-circuit protection.
  • Long-time overload protection (L) helps safeguard conductors and connected equipment against sustained excessive current.
  • Selectable short-time or instantaneous protection supports different short-circuit protection strategies.
  • Adjustable electronic protection characteristics help match the MCCB to the electrical circuit.
  • Short-time delayed protection option can assist with coordination between upstream and downstream protective devices.
  • Instantaneous protection option provides rapid tripping when the selected short-circuit threshold is reached.
  • Electronic protection technology offers precise configuration of the available protection functions.
  • Compact 100 mm three-pole width supports efficient use of space within compatible distribution equipment.
  • ABB SACE Tmax XT2S construction combines robust mechanical design with established electronic circuit protection technology.
  • ABB Protecta Power compatibility supports integration into appropriately configured distribution assemblies.
  • ABB order code identification simplifies product selection, procurement and maintenance documentation.

Key Features

  • ABB Protecta Power Devices product group.
  • EPX-XT2S-E1-1603 product designation.
  • 160 A rated current for low-voltage electrical distribution.
  • Three-pole (3P) construction for three-phase circuits.
  • 50 kA specified short-circuit breaking capacity.
  • Electronic Ekip LS/I trip unit for advanced circuit protection.
  • Long-time protection (L) for sustained overload conditions.
  • Short-time protection (S) option for delayed short-circuit tripping.
  • Instantaneous protection (I) option for rapid short-circuit tripping.
  • Selectable S or I protection mode alongside the long-time protection function.
  • Adjustable overload protection characteristics within the manufacturer's specified settings.
  • Configurable short-circuit protection to support installation requirements.
  • Electronic current sensing for protective trip operation.
  • ABB SACE Tmax XT2S platform with S short-circuit performance classification.
  • XT2 160 frame family for professional low-voltage distribution applications.
  • 100 mm three-pole device width for compact installation.
  • Manual switching mechanism with automatic electronic protective tripping.
  • Robust moulded case construction suitable for commercial and industrial distribution systems.
  • Compatible ABB Protecta Power installation using the appropriate mounting and connection components.
  • ABB order code 1SDX255142R1 for accurate product identification.

Advanced Electronic LS/I Protection for Three-Phase Power Distribution

The ABB EPX-XT2S-E1-1603 provides advanced electronic protection for low-voltage electrical distribution systems where reliable overload protection, configurable short-circuit response and substantial fault-interruption capability are required. Its Ekip LS/I electronic trip unit offers greater flexibility than a conventional fixed-characteristic circuit breaker, helping electrical designers match protective performance to the requirements of the installation.

The long-time protection function (L) provides overload protection for the connected electrical circuit. It responds when current exceeds the configured protection threshold for a sufficient period, helping prevent excessive heating of conductors and connected equipment. Correct adjustment of the long-time protection settings is essential to ensuring that the circuit breaker provides suitable protection for the conductor size, installation method and expected operating load.

The short-time protection function (S) provides a delayed response to short-circuit currents when this mode is selected. The delay can be useful in electrical distribution systems where coordination between upstream and downstream protective devices is required. By allowing a downstream device an opportunity to clear a fault first, a correctly designed protection arrangement may reduce unnecessary disconnection of unaffected circuits.

Alternatively, the instantaneous protection function (I) provides rapid operation when the fault current reaches the selected threshold. This mode is suitable where fast fault interruption is the priority and a short-time delay is not required. The appropriate choice depends on the prospective fault current, connected equipment, conductor withstand characteristics and overall protection strategy.

An important distinction is that LS/I protection does not mean that all three L, S and I functions operate independently at the same time. The ABB Ekip LS/I arrangement provides long-time overload protection together with a choice between short-time delayed and instantaneous short-circuit protection. Where independent L, S and I functions are required together, an LSI trip-unit configuration should be considered.

The 160 A rated current makes the EPX-XT2S-E1-1603 suitable for appropriately designed distribution feeders and outgoing circuits serving substantial electrical loads. Its electronic protection settings allow the MCCB to be configured for the application within the manufacturer's specified adjustment limits. This flexibility is particularly valuable where protection coordination must be considered alongside conductor protection and operational continuity.

The 50 kA short-circuit breaking capacity is a key characteristic of the XT2S platform. Electrical distribution systems can experience prospective short-circuit currents considerably higher than their normal operating currents. The selected MCCB must therefore be capable of interrupting the maximum prospective fault current at its installation point. Breaking-capacity ratings are voltage-dependent, so the applicable ABB technical data should be checked against the actual system operating voltage.

The three-pole construction provides coordinated switching and protection of the three phase conductors. This makes the breaker suitable for three-phase distribution applications where a separately switched neutral pole is not required. For circuits requiring neutral switching, an appropriate four-pole MCCB should be selected instead.

The ABB SACE Tmax XT2S platform combines electronic protection capability with compact mechanical construction. Its 100 mm three-pole width supports efficient integration into compatible electrical distribution assemblies, while the XT2 160 frame family provides a practical solution for professional low-voltage power distribution.

As part of the ABB Protecta Power Devices range, the EPX-XT2S-E1-1603 is intended for installation in compatible panelboards and distribution assemblies using the correct mounting and connection components. Before commissioning, electrical designers and installers should verify the prospective fault current, operating voltage, conductor ratings, electronic trip settings, discrimination requirements and compatibility with the selected distribution assembly.

Typical Applications

  • Commercial and industrial low-voltage electrical distribution systems.
  • ABB Protecta Power panelboards and compatible distribution assemblies.
  • Three-phase outgoing circuit protection.
  • Industrial switchboards and sub-distribution panels.
  • Manufacturing and production facilities.
  • Commercial offices and business premises.
  • Retail buildings and hospitality facilities.
  • Warehouses and logistics centres.
  • Building services electrical distribution.
  • Mechanical plant and appropriately designed three-phase feeder circuits.
  • Distribution circuits requiring electronic overload protection.
  • Installations requiring selectable short-time or instantaneous short-circuit protection.
  • Electrical distribution systems where protection coordination is important.
  • Installations requiring a 50 kA short-circuit breaking capacity.
  • Electrical infrastructure upgrades, maintenance and replacement projects.

Technical Specifications

Product group Protecta Power Devices
Product range Protecta Power
Circuit breaker platform ABB SACE Tmax XT2S
ABB order code 1SDX255142R1
Corresponding ABB XT2S breaker reference 1SDA067804R1
Product type Moulded case circuit breaker (MCCB)
Rated current 160 A
Number of poles 3
Electrical configuration Three-phase
Specified short-circuit breaking capacity 50 kA
Trip unit designation E1
Trip unit type Ekip LS/I
Protection technology Electronic
Long-time overload protection L
Short-time delayed short-circuit protection S, selectable
Instantaneous short-circuit protection I, selectable
LS/I protection arrangement Long-time protection with selection between short-time and instantaneous short-circuit protection
Protection settings Adjustable within the manufacturer's specified limits
Frame family XT2
Frame designation XT2S
Frame current class 160 A
Breaking-capacity classification S
Three-pole device width 100 mm
Operating mechanism Manual switching with automatic electronic protective tripping
Applicable circuit breaker standard IEC 60947-2
Application category Low-voltage electrical power distribution
Mounting application Compatible electrical distribution assemblies
Typical installation ABB Protecta Power panelboards and compatible distribution equipment
Breaking-capacity verification Confirm the applicable short-circuit rating at the installation operating voltage
Protection coordination Verify trip settings and selectivity using ABB technical documentation
Installation requirements Confirm prospective fault current, conductor ratings, operating voltage, protection settings and assembly compatibility before installation

Frequently Asked Questions

What is the ABB EPX-XT2S-E1-1603 used for?

The ABB EPX-XT2S-E1-1603 is a three-pole electronic moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for appropriately designed commercial and industrial installations, including compatible ABB Protecta Power distribution assemblies.

What is the rated current and breaking capacity of this MCCB?

The ABB EPX-XT2S-E1-1603 has a 160 A rated current and a specified 50 kA short-circuit breaking capacity. Its suitability must be assessed against the installation's operating voltage, prospective fault current and applicable protection requirements.

What does LS/I mean on the ABB Ekip electronic trip unit?

LS/I refers to an electronic protection arrangement providing long-time overload protection (L) with a selectable short-circuit protection mode: short-time delayed protection (S) or instantaneous protection (I). The selected mode should be configured according to the electrical installation's protection requirements.

What is the difference between ABB LS/I and LSI protection?

An LS/I trip unit provides long-time overload protection together with a choice between short-time and instantaneous short-circuit protection. An LSI trip unit provides long-time, short-time and instantaneous protection functions independently, offering additional flexibility for protection coordination.

What are the advantages of an electronic MCCB over a thermal-magnetic MCCB?

An electronic MCCB offers configurable protection characteristics that can support more detailed adjustment and coordination of electrical protection. The ABB EPX-XT2S-E1-1603 uses an Ekip LS/I electronic trip unit, providing adjustable long-time protection and selectable short-circuit protection characteristics within the manufacturer's specified limits.

Trusted by Electrical Professionals Worldwide

ABB Protecta Power protective devices combine established circuit protection engineering with practical low-voltage distribution solutions. The EPX-XT2S-E1-1603 offers a compact 160 A, three-pole XT2S MCCB configuration with Ekip LS/I electronic protection and a 50 kA breaking capacity, supporting flexible and dependable circuit protection in appropriately designed commercial and industrial electrical installations.