1SDX255140R1 ABB EPX-XT2S-E1-0633 63A 3-Pole 50kA Ekip LS/I Electronic MCCB

1SDX255140R1 ABB EPX-XT2S-E1-0633 63A 3-Pole 50kA Ekip LS/I Electronic MCCB

ABB EPX-XT2S-E1-0633 is a 63 A three-pole electronic moulded case circuit breaker from the Protecta Power Devices range, featuring a 50 kA breaking capacity at 415 V AC and an Ekip Dip LS/I electronic trip unit with configurable overload and short-circuit protection for low-voltage electrical distribution systems.

SKU: 1SDX255140R1Alt SKU: EPX-XT2S-E1-0633MPN: 1SDX255140R1
Price
List Price £661.37 ex VAT
Your Price (ex VAT)
£661.37
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £661.37
Trade pricing is personalised to your account

Manufacturer Lead Time

£661.37

Why Choose the ABB EPX-XT2S-E1-0633 63A 3-Pole 50kA Electronic MCCB?

The ABB EPX-XT2S-E1-0633 is a high-performance 63 A three-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker incorporates the established ABB SACE Tmax XT2S160 platform, offering electronic protection technology for commercial buildings, industrial facilities and electrical infrastructure.

Equipped with an ABB Ekip Dip LS/I electronic trip unit, the EPX-XT2S-E1-0633 provides configurable protection characteristics for electrical distribution circuits. Its electronic release incorporates long-time overload protection (L) and a selectable short-circuit protection function, allowing the use of short-time delayed protection (S) or instantaneous protection (I) according to the selected configuration. This flexibility supports electrical protection coordination and helps safeguard cables, switchgear and connected equipment against damaging fault conditions.

With a 63 A rated current, three-pole construction and 50 kA short-circuit breaking capacity, this MCCB is suitable for demanding three-phase electrical distribution applications. Its compact XT2S160 frame, electronic trip technology and fixed-mounted construction make it a practical choice for compatible ABB Protecta Power distribution boards and low-voltage switchgear assemblies where reliable circuit protection and adjustable trip characteristics are required.

Key Advantages

  • 63 A rated current for commercial and industrial electrical distribution circuits.
  • Three-pole configuration suitable for three-phase low-voltage electrical systems.
  • 50 kA short-circuit breaking capacity provides substantial fault-interruption capability.
  • ABB Ekip Dip LS/I electronic trip unit delivers configurable overload and short-circuit protection.
  • Long-time overload protection (L) helps protect electrical conductors against sustained excessive current.
  • Selectable short-time (S) or instantaneous (I) protection provides flexibility when configuring short-circuit response.
  • Electronic trip technology supports precise protection settings and repeatable tripping characteristics.
  • Adjustable protection parameters help engineers coordinate circuit protection with other protective devices.
  • ABB SACE Tmax XT2S160 platform combines robust construction with compact dimensions.
  • Fixed-mounted design supports secure installation in compatible distribution assemblies.
  • Front terminal connections provide a practical conductor termination arrangement.
  • Electronic protection without a separate external control supply simplifies circuit breaker integration.
  • Designed for integration into compatible ABB Protecta Power distribution systems.

Key Features

  • ABB Protecta Power Devices product range.
  • ABB SACE Tmax XT2S160 moulded case circuit breaker platform.
  • 63 A rated current.
  • Three-pole (3P) construction.
  • 50 kA short-circuit breaking capacity.
  • Ekip Dip LS/I electronic trip unit.
  • Long-time overload protection (L).
  • Short-time delayed short-circuit protection (S) when selected.
  • Instantaneous short-circuit protection (I) when selected.
  • Configurable electronic protection settings for circuit requirements.
  • XT2S160 frame with a maximum frame rating of 160 A.
  • Fixed-mounted construction for compatible switchboards.
  • Front terminal connections for electrical conductor termination.
  • Manual operating mechanism with trip indication and reset capability.
  • Three-pole switching and protection for three-phase electrical circuits.
  • Designed for low-voltage electrical distribution applications.
  • Compatible with appropriately selected ABB Tmax XT2 accessories.

Electronic LS/I Protection for Industrial Electrical Distribution

Moulded case circuit breakers such as the ABB EPX-XT2S-E1-0633 protect electrical installations by automatically interrupting current during overload and short-circuit conditions. Unlike conventional thermal-magnetic circuit breakers, this model uses an ABB Ekip Dip electronic trip unit to evaluate electrical current and initiate tripping according to its configured protection settings. Its LS/I functionality provides long-time overload protection together with a selectable short-time delayed or instantaneous short-circuit protection function, allowing protection characteristics to be matched to the requirements of the electrical installation.

The ABB SACE Tmax XT2 circuit breaker family is engineered for dependable protection in modern low-voltage electrical distribution assemblies. The EPX-XT2S-E1-0633 is particularly suitable for installations requiring 63 A three-pole electronic circuit protection and a 50 kA breaking capacity at 415 V AC. Its configurable electronic release supports protection coordination between upstream and downstream devices, subject to the selected settings and ABB coordination data. Circuit breaker selection should consider operating voltage, prospective fault current, conductor characteristics, load requirements and the applicable protection study. Where the MCCB supplies a motor circuit, dedicated motor overload protection may also be necessary depending on the installation design.

Typical Applications

  • Commercial and industrial electrical distribution boards.
  • ABB Protecta Power distribution assemblies.
  • Three-phase low-voltage electrical distribution systems.
  • Main and sub-distribution switchboards.
  • Industrial machinery supply circuits and electrical feeders.
  • Manufacturing facilities and industrial workshops.
  • Building services and commercial electrical infrastructure.
  • Warehouses, logistics centres and production facilities.
  • Industrial control panels requiring electronic circuit protection.
  • Electrical installations requiring configurable overload and short-circuit protection.
  • Distribution systems requiring coordination between upstream and downstream protective devices.
  • Low-voltage switchgear assemblies requiring high short-circuit breaking capacity.

Technical Specifications

Product group Protecta Power Devices
Product series SACE Tmax XT
Frame designation XT2S160
ABB order code 1SDX255140R1
ABB base circuit breaker reference 1SDA067802R1
Product type Moulded case circuit breaker (MCCB)
Rated current (In) 63 A
Number of poles 3
Rated ultimate short-circuit breaking capacity (Icu) 50 kA at 415 V AC
Rated service short-circuit breaking capacity (Ics) 50 kA at 415 V AC
Trip unit Ekip Dip LS/I
Trip unit technology Electronic
Long-time protection L – overload protection
Short-time protection S – delayed short-circuit protection, selectable
Instantaneous protection I – instantaneous short-circuit protection, selectable
Protection configuration LS/I
Frame family XT2S160
Maximum frame rating 160 A
Rated operational voltage Up to 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Mounting type Fixed mounting
Terminal arrangement Front terminals
Operating mechanism Manual operation
Application Low-voltage three-phase electrical distribution
Installation Compatible electrical distribution boards and switchgear assemblies
Applicable circuit breaker standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB EPX-XT2S-E1-0633 used for?

The ABB EPX-XT2S-E1-0633 is a three-pole electronic moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for appropriately designed commercial and industrial installations requiring configurable electronic protection.

What is the rated current of the EPX-XT2S-E1-0633?

The circuit breaker has a 63 A rated current and uses the ABB Tmax XT2S160 frame, which has a maximum frame rating of 160 A. The rated current of this specific MCCB is 63 A, not the maximum rating of its frame.

What is the breaking capacity of the ABB EPX-XT2S-E1-0633?

The EPX-XT2S-E1-0633 has a rated ultimate short-circuit breaking capacity of 50 kA at 415 V AC. The corresponding ABB XT2S electronic breaker also has a rated service short-circuit breaking capacity of 50 kA at 415 V AC. The applicable ratings must be checked against the installation voltage and prospective fault current before selection.

What does LS/I mean on the ABB Ekip electronic trip unit?

LS/I identifies an electronic trip unit providing long-time overload protection (L) together with a selectable short-circuit protection function. The unit can be configured to use short-time delayed protection (S) or instantaneous protection (I). Unlike an LSI trip unit, LS/I does not provide independently active S and I functions simultaneously.

What is the difference between an Ekip LS/I electronic MCCB and a TMA thermal-magnetic MCCB?

An Ekip LS/I electronic MCCB uses an electronic release to evaluate current and apply configurable overload and short-circuit protection settings. A TMA thermal-magnetic MCCB uses thermal and magnetic trip elements to respond to electrical faults. Electronic protection provides additional flexibility when configuring trip characteristics and coordinating protective devices within an electrical distribution system.

Trusted by Electrical Engineers and Industrial Installers Worldwide

ABB SACE Tmax XT moulded case circuit breakers are engineered to deliver dependable overload and short-circuit protection in modern electrical distribution systems. The ABB EPX-XT2S-E1-0633 combines a 63 A rating, three-pole construction, 50 kA breaking capacity at 415 V AC and configurable Ekip Dip LS/I electronic protection in a compact circuit breaker suitable for commercial, industrial and infrastructure power distribution applications.