ABB EPX-XT5S-TM3204 (1SDX255134R1) is a Protecta Power Devices 320 A, 4-pole moulded case circuit breaker with a specified 50 kA breaking capacity and TMA thermal-magnetic protection for compatible low-voltage electrical distribution systems.
£1,881.25
The ABB EPX-XT5S-TM3204 is a 320 A, 4-pole moulded case circuit breaker (MCCB) with a specified 50 kA breaking capacity and TMA thermal-magnetic protection. Belonging to the ABB Protecta Power Devices product group, this circuit breaker is designed for low-voltage electrical distribution applications requiring overload and short-circuit protection.
The EPX-XT5S-TM3204 combines a 320 A current rating with a four-pole configuration, making it suitable for appropriately designed three-phase, four-wire distribution systems. Its TMA thermal-magnetic protection arrangement combines thermal overload protection with magnetic short-circuit protection, supporting the protection of electrical circuits and connected equipment.
With its specified 50 kA breaking capacity, the EPX-XT5S-TM3204 is intended for applications where the prospective fault current and operating conditions are compatible with the circuit breaker's verified performance. Identified by ABB order code 1SDX255134R1, it provides a manufacturer-specific MCCB solution for electrical contractors, panel builders, consulting engineers and maintenance professionals working with compatible ABB Protecta Power distribution equipment.
Industrial and commercial electrical distribution systems require circuit breakers capable of protecting electrical conductors and equipment against abnormal current conditions. The ABB EPX-XT5S-TM3204 provides a 320 A, four-pole MCCB configuration with TMA thermal-magnetic protection for appropriately engineered low-voltage installations.
The thermal protection element responds to sustained overload currents that can cause excessive heating of electrical conductors and connected equipment. The magnetic protection element responds to short-circuit conditions involving high fault currents. Together, these protection functions provide overcurrent protection according to the circuit breaker's applicable operating characteristics.
The four-pole configuration is relevant to three-phase, four-wire distribution arrangements where a fourth switched pole is required. The precise neutral-pole protection and switching characteristics must be verified from the applicable ABB technical documentation. A four-pole designation alone does not establish the neutral protection settings or suitability for every earthing arrangement.
The specified 50 kA breaking capacity is a critical consideration when selecting the MCCB for an electrical distribution system. The prospective short-circuit current at the installation point must be calculated or otherwise established, and the relevant breaking-capacity rating must be checked against the system operating voltage and ABB product data. The stated 50 kA value should not be assumed to apply identically at every voltage or under every installation condition.
The EPX-XT5S-TM3204 should be selected with consideration for conductor sizing, continuous load, installation conditions, protective device coordination and the electrical characteristics of the complete distribution assembly. Relevant requirements of BS EN IEC 60947-2 should be considered for circuit breaker selection, while any applicable BS EN IEC 61439 compliance must be established for the complete verified switchgear assembly rather than assumed from the individual MCCB.
The ABB EPX-XT5S-TM3204 is a 320 A, 4-pole moulded case circuit breaker designed for low-voltage electrical distribution applications. It provides TMA thermal-magnetic overload and short-circuit protection for appropriately designed electrical circuits.
The EPX-XT5S-TM3204 has a specified 320 A rated current. The breaker must be selected according to the circuit load, conductor characteristics, installation conditions and applicable ABB protection characteristics.
The 50 kA rating identifies the specified short-circuit breaking capacity of the MCCB. The applicable breaking capacity must be verified at the intended operating voltage and compared with the prospective fault current at the installation point using ABB technical documentation.
4P indicates a four-pole circuit breaker configuration, while TMA identifies thermal-magnetic protection for overload and short-circuit conditions. The precise neutral-pole characteristics, protection settings and adjustment capabilities should be confirmed from the applicable ABB product documentation.
The official ABB order code is 1SDX255134R1. The manufacturer product designation is EPX-XT5S-TM3204, identifying a 320 A, 4-pole, 50 kA thermal-magnetic MCCB within the ABB Protecta Power Devices product group.
ABB Protecta Power Devices provide circuit protection solutions for professional low-voltage electrical distribution installations. The EPX-XT5S-TM3204 combines a 320 A current rating, four-pole construction, specified 50 kA breaking capacity and TMA thermal-magnetic protection, supporting appropriately engineered industrial and commercial power distribution systems.