ABB EPX-XT4S-TM2504 is a 250 A four-pole moulded case circuit breaker with 50 kA breaking capacity at 415 V AC, adjustable thermal-magnetic overload and short-circuit protection and a fully rated neutral, designed for commercial and industrial low-voltage electrical distribution systems.
£1,546.11
The ABB EPX-XT4S-TM2504 is a robust, high-performance 250 A four-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in commercial and industrial electrical distribution systems. Featuring a 50 kA short-circuit breaking capacity at 415 V AC and thermal-magnetic (TMA) protection, this circuit breaker belongs to the ABB Protecta Power Devices range and is based on the established ABB SACE Tmax XT4S250 circuit breaker platform.
Engineered for dependable low-voltage electrical protection, the EPX-XT4S-TM2504 combines adjustable thermal overload protection with adjustable magnetic short-circuit protection to help safeguard electrical cables, distribution circuits and connected equipment. Its four-pole construction provides simultaneous switching of three phase conductors and a neutral conductor, making it particularly suitable for three-phase electrical distribution systems requiring four-pole switching and isolation.
With a 250 A rated current, four-pole (4P) configuration and 50 kA breaking capacity, the ABB EPX-XT4S-TM2504 provides an effective solution for higher-current outgoing circuits, electrical sub-distribution systems and industrial power distribution installations. Its 250 A frame class, adjustable protection settings and fully rated neutral support reliable operation within compatible ABB Protecta Power assemblies. The product is identified by ABB order code 1SDX255133R1.
Moulded case circuit breakers such as the ABB EPX-XT4S-TM2504 protect low-voltage electrical installations by automatically interrupting current when an overload or short-circuit fault occurs. By combining circuit switching with protective tripping functions, an MCCB helps reduce the risk of damage to electrical cables, distribution equipment and connected electrical loads.
The thermal-magnetic (TMA) protection system uses two complementary operating principles. The thermal element responds to sustained overcurrent conditions that may cause excessive heating, while the magnetic element provides rapid operation when a significant short-circuit fault occurs. The adjustable trip settings allow the protective response to be configured within the manufacturer's specified ranges to suit the electrical installation.
The EPX-XT4S-TM2504 features an adjustable thermal overload setting of 175–250 A and an adjustable magnetic trip setting of 1,250–2,500 A. These settings provide flexibility when coordinating the circuit breaker with cable capacities, connected loads and other protective devices. Appropriate settings must be determined according to the installation design and applicable electrical standards.
The four-pole configuration makes the EPX-XT4S-TM2504 particularly useful in three-phase electrical distribution systems requiring switching of the neutral conductor alongside the three phase conductors. Its fully rated neutral provides a neutral current rating equal to the phase current rating, supporting applications where full neutral protection is specified.
As part of the ABB Protecta Power Devices range, this MCCB is designed for integration into compatible electrical distribution equipment. The XT4S250 platform provides robust circuit breaker construction, while the 250 A current rating and 50 kA breaking capacity at 415 V AC make the device suitable for higher-current circuits requiring substantial short-circuit protection capability.
The ABB SACE Tmax XT4S platform is designed for professional electrical distribution applications where reliability, maintainability and protective device coordination are essential. Correct circuit breaker selection should account for the electrical system voltage, prospective short-circuit current, cable ratings, load characteristics and coordination with upstream and downstream protective devices. Breaking capacity varies with operating voltage and must be verified against the installation's fault level.
| Product group | Protecta Power Devices |
|---|---|
| Series | SACE Tmax XT4S |
| Circuit breaker platform | XT4S250 |
| ABB order code | 1SDX255133R1 |
| Corresponding ABB circuit breaker reference | 1SDA068331R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 250 A |
| Number of poles | 4 |
| Pole configuration | Four-pole (3-phase + neutral) |
| Neutral rating | 100% of phase current rating |
| Short-circuit breaking capacity | 50 kA at 415 V AC |
| Rated service short-circuit breaking capacity (Ics) | 50 kA at 380–440 V AC |
| Trip unit type | Thermal-magnetic (TMA) |
| Overload protection | Adjustable thermal trip mechanism |
| Thermal overload adjustment range | 175–250 A |
| Short-circuit protection | Adjustable magnetic trip mechanism |
| Magnetic trip adjustment range | 1,250–2,500 A |
| Frame family | XT4S250 |
| Frame current class | 250 A |
| Rated operational voltage (Ue), XT4S platform | Up to 690 V AC |
| Rated insulation voltage (Ui) | 1,000 V |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Mounting arrangement | Fixed installation |
| Terminal arrangement | Front terminals |
| Switching operation | Manual lever operation with automatic protective tripping |
| Applicable product standard | IEC 60947-2 |
| Electrical system | Low-voltage AC distribution |
| Application | Commercial and industrial electrical circuit protection |
| Installation type | Compatible electrical distribution boards and switchgear assemblies |
| Product construction | Moulded case circuit breaker |
The ABB EPX-XT4S-TM2504 is a four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for commercial and industrial installations, including compatible ABB Protecta Power distribution boards and higher-current outgoing circuits.
The circuit breaker has a rated current of 250 A and uses the 250 A XT4S frame class. It is designed to protect appropriately rated electrical circuits, subject to correct cable sizing, load assessment and protective device coordination.
The ABB EPX-XT4S-TM2504 has a specified 50 kA short-circuit breaking capacity at 415 V AC. The corresponding XT4S250 circuit breaker also has a rated service short-circuit breaking capacity of 50 kA at 380–440 V AC. Breaking capacity varies with operating voltage, so suitability must be verified against the installation's prospective fault current.
TMA refers to thermal-magnetic protection. The thermal element provides protection against sustained overload conditions, while the magnetic element provides rapid tripping during short-circuit faults. The TMA trip unit offers adjustable protection settings for appropriate circuit coordination.
Yes. The thermal-magnetic TMA trip unit provides adjustable overload and short-circuit protection. The corresponding XT4S250 250 A TMA configuration has a thermal adjustment range of 175–250 A and a magnetic adjustment range of 1,250–2,500 A.
A four-pole MCCB enables simultaneous switching of three phase conductors and a neutral conductor. The EPX-XT4S-TM2504 uses a 100% rated neutral, providing a neutral current rating equal to the phase current rating for appropriately designed three-phase distribution systems.
The ABB Protecta Power manufacturer order code is 1SDX255133R1. The corresponding ABB XT4S250 circuit breaker reference is 1SDA068331R1. The product reference EPX-XT4S-TM2504 identifies the 250 A, four-pole, 50 kA thermal-magnetic MCCB.
The product belongs to the ABB SACE Tmax XT4S series and uses the XT4S250 circuit breaker platform. The XT4S250 designation identifies the 250 A frame class, and this particular MCCB also has a rated current of 250 A.
The corresponding ABB XT4S250 circuit breaker platform supports a rated operational voltage of up to 690 V AC, with a rated insulation voltage of 1,000 V and a rated impulse withstand voltage of 8 kV. The available short-circuit breaking capacity depends on the operating voltage.
This MCCB is typically installed within compatible electrical distribution boards, low-voltage switchgear assemblies and power distribution panels. Its four-pole configuration and XT4S250 construction support integration into suitably configured ABB Protecta Power equipment.
ABB is an established manufacturer of electrical protection and power distribution equipment. The ABB Protecta Power Devices range, including the EPX-XT4S-TM2504 four-pole thermal-magnetic MCCB, provides electrical contractors, panel builders and facilities engineers with dependable circuit protection solutions for commercial and industrial low-voltage distribution systems.