ABB EPX-XT4S-TM2004 is a 200 A four-pole moulded case circuit breaker with 50 kA breaking capacity, adjustable thermal-magnetic overload and short-circuit protection and a fully rated neutral, designed for commercial and industrial low-voltage electrical distribution systems.
£1,287.84
The ABB EPX-XT4S-TM2004 is a robust, high-performance 200 A four-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in commercial and industrial electrical distribution systems. Featuring a 50 kA short-circuit breaking capacity and thermal-magnetic (TMA) protection, this circuit breaker belongs to the ABB Protecta Power Devices range and uses the established ABB SACE Tmax XT4S250 circuit breaker platform.
Engineered for reliable low-voltage electrical protection, the EPX-XT4S-TM2004 combines adjustable thermal overload protection with magnetic short-circuit protection to help safeguard distribution circuits, electrical cables and connected equipment. Its four-pole configuration provides simultaneous switching of three phase conductors and a neutral conductor, making it particularly suitable for three-phase electrical distribution systems where four-pole switching and isolation are required.
With a 200 A rated current, four-pole (4P) configuration and 50 kA breaking capacity, the ABB EPX-XT4S-TM2004 provides an effective solution for higher-current outgoing circuits, sub-distribution systems and industrial power distribution installations. Its 250 A frame class, adjustable thermal-magnetic protection and compact moulded case construction support reliable operation within compatible ABB Protecta Power assemblies. The product is identified by ABB order code 1SDX255132R1.
Moulded case circuit breakers such as the ABB EPX-XT4S-TM2004 protect low-voltage electrical installations by automatically interrupting current when an overload or short-circuit fault occurs. By combining circuit switching with protective tripping functions, an MCCB helps reduce the risk of damage to electrical cables, distribution equipment and connected electrical loads.
The thermal-magnetic (TMA) protection system uses two complementary operating principles. The thermal element responds to sustained overcurrent conditions that may cause excessive heating, while the magnetic element provides rapid operation when a significant short-circuit fault occurs. The adjustable trip settings allow the protective response to be configured within the manufacturer's specified ranges to suit the electrical installation.
The four-pole configuration makes the EPX-XT4S-TM2004 particularly useful in three-phase electrical distribution systems requiring switching of the neutral conductor alongside the three phase conductors. Its fully rated neutral provides a neutral current rating equal to the phase current rating, making the device suitable for appropriately designed installations where full neutral protection is specified.
As part of the ABB Protecta Power Devices range, this MCCB is designed for integration into compatible electrical distribution equipment. The XT4S250 platform provides robust circuit breaker construction, while the 200 A current rating and 50 kA breaking capacity make the device suitable for higher-current distribution circuits requiring substantial short-circuit protection capability.
The ABB SACE Tmax XT4S platform is designed for professional electrical distribution applications where reliability, maintainability and protective device coordination are important. Correct circuit breaker selection should account for the electrical system voltage, prospective short-circuit current, cable ratings, load characteristics and coordination with upstream and downstream protective devices. The stated breaking capacity must be assessed against the applicable operating voltage and installation conditions.
| Product group | Protecta Power Devices |
|---|---|
| Series | SACE Tmax XT4S |
| Circuit breaker platform | XT4S250 |
| ABB order code | 1SDX255132R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 200 A |
| Number of poles | 4 |
| Pole configuration | Four-pole (3-phase + neutral) |
| Neutral rating | 100% of phase current rating |
| Short-circuit breaking capacity | 50 kA |
| Trip unit type | Thermal-magnetic (TMA) |
| Overload protection | Adjustable thermal trip mechanism |
| Thermal overload adjustment range | 140–200 A |
| Short-circuit protection | Adjustable magnetic trip mechanism |
| Magnetic trip adjustment range | 1,000–2,000 A |
| Frame family | XT4S250 |
| Frame current class | 250 A |
| Four-pole device width | 140 mm |
| Rated operational voltage, XT4S platform | Up to 690 V AC |
| Protection rating | IP20 |
| Mounting arrangement | Fixed installation |
| Terminal arrangement | Front terminals |
| Switching operation | Manual toggle operation with automatic protective tripping |
| Electrical system | Low-voltage AC distribution |
| Application | Commercial and industrial electrical circuit protection |
| Installation type | Compatible electrical distribution boards and switchgear assemblies |
| Product construction | Moulded case circuit breaker |
The ABB EPX-XT4S-TM2004 is a four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for commercial and industrial installations, including compatible ABB Protecta Power distribution boards and higher-current outgoing circuits.
The circuit breaker has a rated current of 200 A and uses the 250 A XT4S frame class. It is designed to protect appropriately rated electrical circuits, subject to correct cable sizing, load assessment and protective device coordination.
The ABB EPX-XT4S-TM2004 has a specified 50 kA short-circuit breaking capacity. The suitability of this rating must be verified against the installation's operating voltage and prospective short-circuit current.
TMA refers to thermal-magnetic protection. The thermal element provides protection against sustained overload conditions, while the magnetic element provides rapid tripping during short-circuit faults. The TMA trip unit offers adjustable protection settings for appropriate circuit coordination.
Yes. The thermal-magnetic TMA trip unit provides adjustable overload and short-circuit protection. The corresponding XT4S250 200 A TMA configuration has a thermal adjustment range of 140–200 A and a magnetic adjustment range of 1,000–2,000 A.
A four-pole MCCB enables simultaneous switching of three phase conductors and a neutral conductor. The EPX-XT4S-TM2004 uses a 100% rated neutral, providing a neutral current rating equal to the phase current rating for appropriately designed three-phase distribution systems.
The ABB manufacturer order code is 1SDX255132R1. The corresponding product reference is EPX-XT4S-TM2004, identifying the 200 A, four-pole, 50 kA thermal-magnetic MCCB within the ABB Protecta Power Devices range.
The product belongs to the ABB SACE Tmax XT4S series and uses the XT4S250 circuit breaker platform. The XT4S250 designation identifies the 250 A frame class, while this particular MCCB has a rated current of 200 A.
The ABB EPX-XT4S-TM2004 uses the 140 mm wide four-pole XT4S format. This compact construction supports efficient use of space within compatible electrical distribution boards and switchgear assemblies.
This MCCB is typically installed within compatible electrical distribution boards, low-voltage switchgear assemblies and power distribution panels. Its four-pole configuration and XT4S250 construction support integration into suitably configured ABB Protecta Power equipment.
ABB is an established manufacturer of electrical protection and power distribution equipment. The ABB Protecta Power Devices range, including the EPX-XT4S-TM2004 four-pole thermal-magnetic MCCB, provides electrical contractors, panel builders and facilities engineers with dependable circuit protection solutions for commercial and industrial low-voltage distribution systems.