1SDX255132R1 ABB EPX-XT4S-TM2004 200A 4-Pole 50kA Thermal-Magnetic MCCB

1SDX255132R1 ABB EPX-XT4S-TM2004 200A 4-Pole 50kA Thermal-Magnetic MCCB

ABB EPX-XT4S-TM2004 is a 200 A four-pole moulded case circuit breaker with 50 kA breaking capacity, adjustable thermal-magnetic overload and short-circuit protection and a fully rated neutral, designed for commercial and industrial low-voltage electrical distribution systems.

SKU: 1SDX255132R1Alt SKU: EPX-XT4S-TM2004MPN: 1SDX255132R1
Price
List Price £1,287.84 ex VAT
Your Price (ex VAT)
£1,287.84
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,287.84
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,287.84

Why Choose the ABB EPX-XT4S-TM2004 200A 4-Pole MCCB?

The ABB EPX-XT4S-TM2004 is a robust, high-performance 200 A four-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in commercial and industrial electrical distribution systems. Featuring a 50 kA short-circuit breaking capacity and thermal-magnetic (TMA) protection, this circuit breaker belongs to the ABB Protecta Power Devices range and uses the established ABB SACE Tmax XT4S250 circuit breaker platform.

Engineered for reliable low-voltage electrical protection, the EPX-XT4S-TM2004 combines adjustable thermal overload protection with magnetic short-circuit protection to help safeguard distribution circuits, electrical cables and connected equipment. Its four-pole configuration provides simultaneous switching of three phase conductors and a neutral conductor, making it particularly suitable for three-phase electrical distribution systems where four-pole switching and isolation are required.

With a 200 A rated current, four-pole (4P) configuration and 50 kA breaking capacity, the ABB EPX-XT4S-TM2004 provides an effective solution for higher-current outgoing circuits, sub-distribution systems and industrial power distribution installations. Its 250 A frame class, adjustable thermal-magnetic protection and compact moulded case construction support reliable operation within compatible ABB Protecta Power assemblies. The product is identified by ABB order code 1SDX255132R1.

Key Advantages

  • Robust 200 A moulded case circuit breaker designed for commercial and industrial low-voltage distribution.
  • 50 kA short-circuit breaking capacity provides high fault-interruption capability for demanding electrical installations.
  • Four-pole configuration enables simultaneous switching of three phases and neutral.
  • Thermal-magnetic (TMA) protection provides dependable overload and short-circuit protection.
  • Adjustable thermal overload protection allows protective settings to be matched to appropriately designed circuits.
  • Adjustable magnetic short-circuit protection supports coordination with electrical distribution requirements.
  • Based on the ABB SACE Tmax XT4S250 platform with a 250 A frame class.
  • Fully rated neutral protection provides a neutral current rating equal to the phase current rating.
  • Compact 140 mm four-pole format supports efficient integration into compatible distribution equipment.
  • Designed for use with compatible ABB Protecta Power distribution boards and switchgear assemblies.

Key Features

  • ABB Protecta Power Devices product group.
  • ABB SACE Tmax XT4S250 moulded case circuit breaker platform.
  • 200 A rated current for appropriately designed electrical distribution circuits.
  • 50 kA short-circuit breaking capacity.
  • Four-pole (4P) construction for three-phase and neutral switching.
  • Thermal-magnetic (TMA) trip unit for combined overload and short-circuit protection.
  • Adjustable thermal overload setting for circuit protection flexibility.
  • Adjustable magnetic trip setting for short-circuit protection coordination.
  • 100% rated neutral for the four-pole configuration.
  • 250 A frame class with a 200 A rated trip unit.
  • Compact 140 mm four-pole width for space-efficient panel installation.
  • Manual operating mechanism with automatic protective tripping.
  • Fixed-mounted circuit breaker construction with front electrical terminals.
  • Suitable for compatible ABB Protecta Power electrical distribution assemblies.
  • ABB manufacturer order code: 1SDX255132R1.

Reliable Four-Pole Circuit Protection for Industrial Power Distribution

Moulded case circuit breakers such as the ABB EPX-XT4S-TM2004 protect low-voltage electrical installations by automatically interrupting current when an overload or short-circuit fault occurs. By combining circuit switching with protective tripping functions, an MCCB helps reduce the risk of damage to electrical cables, distribution equipment and connected electrical loads.

The thermal-magnetic (TMA) protection system uses two complementary operating principles. The thermal element responds to sustained overcurrent conditions that may cause excessive heating, while the magnetic element provides rapid operation when a significant short-circuit fault occurs. The adjustable trip settings allow the protective response to be configured within the manufacturer's specified ranges to suit the electrical installation.

The four-pole configuration makes the EPX-XT4S-TM2004 particularly useful in three-phase electrical distribution systems requiring switching of the neutral conductor alongside the three phase conductors. Its fully rated neutral provides a neutral current rating equal to the phase current rating, making the device suitable for appropriately designed installations where full neutral protection is specified.

As part of the ABB Protecta Power Devices range, this MCCB is designed for integration into compatible electrical distribution equipment. The XT4S250 platform provides robust circuit breaker construction, while the 200 A current rating and 50 kA breaking capacity make the device suitable for higher-current distribution circuits requiring substantial short-circuit protection capability.

The ABB SACE Tmax XT4S platform is designed for professional electrical distribution applications where reliability, maintainability and protective device coordination are important. Correct circuit breaker selection should account for the electrical system voltage, prospective short-circuit current, cable ratings, load characteristics and coordination with upstream and downstream protective devices. The stated breaking capacity must be assessed against the applicable operating voltage and installation conditions.

Typical Applications

  • Commercial building electrical distribution systems.
  • ABB Protecta Power distribution board installations.
  • Three-phase and neutral outgoing circuit protection.
  • Industrial electrical distribution panels.
  • Low-voltage switchgear and power distribution assemblies.
  • Commercial premises, offices, retail buildings and warehouses.
  • Building services and mechanical equipment distribution circuits.
  • Industrial manufacturing and production facilities.
  • Electrical sub-distribution boards and appropriately rated feeder circuits.
  • Power distribution systems requiring high short-circuit interruption capability.
  • Three-phase distribution circuits requiring a fully rated neutral.
  • Electrical infrastructure requiring adjustable thermal-magnetic protection.
  • Distribution board upgrades and replacement installations where electrical and mechanical compatibility has been verified.

Technical Specifications

Product group Protecta Power Devices
Series SACE Tmax XT4S
Circuit breaker platform XT4S250
ABB order code 1SDX255132R1
Product type Moulded case circuit breaker (MCCB)
Rated current 200 A
Number of poles 4
Pole configuration Four-pole (3-phase + neutral)
Neutral rating 100% of phase current rating
Short-circuit breaking capacity 50 kA
Trip unit type Thermal-magnetic (TMA)
Overload protection Adjustable thermal trip mechanism
Thermal overload adjustment range 140–200 A
Short-circuit protection Adjustable magnetic trip mechanism
Magnetic trip adjustment range 1,000–2,000 A
Frame family XT4S250
Frame current class 250 A
Four-pole device width 140 mm
Rated operational voltage, XT4S platform Up to 690 V AC
Protection rating IP20
Mounting arrangement Fixed installation
Terminal arrangement Front terminals
Switching operation Manual toggle operation with automatic protective tripping
Electrical system Low-voltage AC distribution
Application Commercial and industrial electrical circuit protection
Installation type Compatible electrical distribution boards and switchgear assemblies
Product construction Moulded case circuit breaker

Frequently Asked Questions

What is the ABB EPX-XT4S-TM2004 used for?

The ABB EPX-XT4S-TM2004 is a four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for commercial and industrial installations, including compatible ABB Protecta Power distribution boards and higher-current outgoing circuits.

What is the rated current of the ABB EPX-XT4S-TM2004?

The circuit breaker has a rated current of 200 A and uses the 250 A XT4S frame class. It is designed to protect appropriately rated electrical circuits, subject to correct cable sizing, load assessment and protective device coordination.

What is the breaking capacity of this MCCB?

The ABB EPX-XT4S-TM2004 has a specified 50 kA short-circuit breaking capacity. The suitability of this rating must be verified against the installation's operating voltage and prospective short-circuit current.

What does TMA mean on the ABB EPX-XT4S-TM2004?

TMA refers to thermal-magnetic protection. The thermal element provides protection against sustained overload conditions, while the magnetic element provides rapid tripping during short-circuit faults. The TMA trip unit offers adjustable protection settings for appropriate circuit coordination.

Are the protection settings adjustable on the ABB EPX-XT4S-TM2004?

Yes. The thermal-magnetic TMA trip unit provides adjustable overload and short-circuit protection. The corresponding XT4S250 200 A TMA configuration has a thermal adjustment range of 140–200 A and a magnetic adjustment range of 1,000–2,000 A.

What is the advantage of a four-pole MCCB with a fully rated neutral?

A four-pole MCCB enables simultaneous switching of three phase conductors and a neutral conductor. The EPX-XT4S-TM2004 uses a 100% rated neutral, providing a neutral current rating equal to the phase current rating for appropriately designed three-phase distribution systems.

What is the ABB order code for the EPX-XT4S-TM2004?

The ABB manufacturer order code is 1SDX255132R1. The corresponding product reference is EPX-XT4S-TM2004, identifying the 200 A, four-pole, 50 kA thermal-magnetic MCCB within the ABB Protecta Power Devices range.

What circuit breaker series does the EPX-XT4S-TM2004 belong to?

The product belongs to the ABB SACE Tmax XT4S series and uses the XT4S250 circuit breaker platform. The XT4S250 designation identifies the 250 A frame class, while this particular MCCB has a rated current of 200 A.

What is the width of the ABB EPX-XT4S-TM2004?

The ABB EPX-XT4S-TM2004 uses the 140 mm wide four-pole XT4S format. This compact construction supports efficient use of space within compatible electrical distribution boards and switchgear assemblies.

Where is the ABB EPX-XT4S-TM2004 typically installed?

This MCCB is typically installed within compatible electrical distribution boards, low-voltage switchgear assemblies and power distribution panels. Its four-pole configuration and XT4S250 construction support integration into suitably configured ABB Protecta Power equipment.

Trusted by Electrical Professionals Worldwide

ABB is an established manufacturer of electrical protection and power distribution equipment. The ABB Protecta Power Devices range, including the EPX-XT4S-TM2004 four-pole thermal-magnetic MCCB, provides electrical contractors, panel builders and facilities engineers with dependable circuit protection solutions for commercial and industrial low-voltage distribution systems.