Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB EPX-XT4S-TM1254 is a 125 A four-pole moulded case circuit breaker with 50 kA breaking capacity and an adjustable thermal-magnetic trip unit, designed for overload and short-circuit protection in low-voltage electrical distribution systems.
£1,137.76
The ABB EPX-XT4S-TM1254 is a high-performance 125 A, 4-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. Featuring a 50 kA breaking capacity and a thermal-magnetic adjustable (TMA) trip unit, this circuit breaker delivers dependable electrical protection for commercial, industrial and building services installations.
As part of the ABB Protecta Power Devices range, the EPX-XT4S-TM1254 incorporates proven ABB SACE Tmax XT4S circuit breaker technology. Its thermal-magnetic protection system combines adjustable thermal overload protection with magnetic short-circuit protection, helping safeguard electrical cables, distribution equipment and connected installations against damaging fault conditions.
With a 125 A rated current, four-pole configuration and 50 kA short-circuit breaking capacity at 415 V AC, the EPX-XT4S-TM1254 is suitable for three-phase electrical distribution systems requiring neutral conductor switching. Its compact XT4S160 frame design supports efficient integration into ABB Protecta Power distribution boards, electrical switchboards and compatible low-voltage switchgear assemblies.
The ABB EPX-XT4S-TM1254 provides effective electrical protection through its thermal-magnetic adjustable trip mechanism. The thermal protection element responds to sustained overload conditions, while the magnetic protection element provides rapid tripping during high-current short-circuit faults. These complementary protection functions help minimise the risk of damage to electrical conductors, connected equipment and distribution infrastructure.
The ABB SACE Tmax XT4S160 platform is designed for reliable operation in low-voltage electrical networks. Its four-pole configuration enables coordinated switching of three phase conductors and the neutral conductor, while adjustable protection settings support coordination with upstream and downstream electrical equipment. Combined with its 125 A rated current and 50 kA breaking capacity, this MCCB provides dependable protection for commercial and industrial electrical distribution systems.
| Product range | Protecta Power Devices |
|---|---|
| Series | SACE Tmax XT4S |
| ABB order code | 1SDX255130R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 125 A |
| Number of poles | 4 |
| Rated ultimate short-circuit breaking capacity (Icu) | 50 kA at 415 V AC |
| Trip unit type | TMA – thermal-magnetic adjustable |
| Thermal adjustment range | 87.5–125 A |
| Magnetic trip adjustment range | 625–1250 A |
| Protection functions | Thermal overload and magnetic short-circuit protection |
| Frame designation | XT4S160 |
| Frame rated current | 160 A |
| Rated operational voltage | Up to 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Electrical system | Three-phase with neutral |
| Operating mechanism | Mechanical toggle operation |
| Application | Low-voltage electrical distribution |
| Applicable standard | IEC 60947-2 |
| Product group | Protecta Power Devices |
The ABB EPX-XT4S-TM1254 is a four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits in commercial and industrial installations.
The circuit breaker has a 125 A rated current and belongs to the ABB SACE Tmax XT4S160 frame family, which has a frame current rating of 160 A.
The EPX-XT4S-TM1254 has a 50 kA rated ultimate short-circuit breaking capacity at 415 V AC. The prospective fault current and applicable operating conditions must be considered when selecting the circuit breaker.
TMA stands for thermal-magnetic adjustable. The trip unit provides adjustable thermal overload protection and magnetic short-circuit protection. The corresponding XT4 TMA 125 A release has a thermal adjustment range of 87.5–125 A and a magnetic trip adjustment range of 625–1250 A.
The four-pole design allows coordinated switching of all three phase conductors and the neutral conductor, making the MCCB suitable for electrical distribution systems requiring four-pole switching and isolation.
ABB SACE Tmax XT moulded case circuit breakers are engineered to deliver dependable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. The EPX-XT4S-TM1254 combines a 125 A rated current, four-pole construction, 50 kA breaking capacity and adjustable thermal-magnetic protection in a robust XT4S160 frame for reliable electrical distribution applications.