ABB EPX-XT4S-TM1004 is a 100 A four-pole 50 kA moulded case circuit breaker from the Protecta Power Devices range, featuring TMA thermal-magnetic overload and short-circuit protection for low-voltage three-phase electrical distribution systems.
£1,010.94
The ABB EPX-XT4S-TM1004 is a high-performance 100 A four-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker combines the established ABB SACE Tmax XT4S platform with TMA thermal-magnetic protection and a specified 50 kA short-circuit breaking capacity.
Designed for three-phase electrical distribution applications requiring four-pole switching, the EPX-XT4S-TM1004 provides coordinated operation of three phase conductors and a neutral conductor. Its 100 A rated current makes it suitable for appropriately designed outgoing feeders, distribution circuits and equipment supplies, while the XT4S performance designation identifies a higher short-circuit performance version within the ABB Tmax XT4 family.
The TMA thermal-magnetic protection system combines thermal overload protection with magnetic short-circuit protection. The thermal element responds to sustained excessive current, helping protect conductors and connected equipment against overheating, while the magnetic element provides rapid tripping during short-circuit conditions. This established protection technology operates without requiring an external electronic trip power supply, making the breaker a practical choice for commercial installations, industrial switchboards and compatible ABB Protecta Power distribution assemblies.
The ABB EPX-XT4S-TM1004 provides circuit protection through the combined operation of thermal and magnetic trip mechanisms. The thermal protection element responds to sustained overload conditions according to its time-current characteristics, helping reduce the risk of excessive heating in electrical conductors, terminals and connected equipment. This is particularly important in commercial and industrial installations where distribution circuits must be protected against abnormal operating currents.
The magnetic protection element provides rapid response to short-circuit conditions. When fault current reaches the applicable magnetic trip threshold, the breaker initiates interruption of the affected circuit. The TMA protection arrangement offers conventional thermal-magnetic characteristics, with the exact available adjustments determined by the supplied trip unit. Electrical engineers should confirm the device's thermal and magnetic settings against its markings and manufacturer documentation to ensure suitable cable protection and coordination with other protective devices.
The ABB SACE Tmax XT4S platform combines this protection technology with a specified 50 kA short-circuit breaking capacity, providing a practical solution for electrical installations requiring substantial fault interruption capability. Its four-pole design allows coordinated switching of the three phase conductors and neutral, supporting applications where four-pole isolation is required. The prospective short-circuit current, operating voltage, neutral conductor arrangement and protection coordination should be verified before installation and commissioning.
| Product group | Protecta Power Devices |
|---|---|
| Product family | SACE Tmax XT |
| Product series | XT4S |
| Product model | EPX-XT4S-TM1004 |
| ABB order code | 1SDX255129R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current (In) | 100 A |
| Number of poles | 4 |
| Specified short-circuit breaking capacity | 50 kA |
| Trip unit designation | TMA |
| Trip unit technology | Thermal-magnetic |
| Overload protection | Thermal trip mechanism |
| Short-circuit protection | Magnetic trip mechanism |
| Thermal adjustment | According to the supplied trip unit setting range |
| Magnetic adjustment | According to the supplied trip unit configuration |
| Electrical system | Low-voltage AC distribution |
| Phase configuration | Three-phase with neutral |
| Switching configuration | Four-pole |
| Operating method | Manual circuit breaker operation |
| Primary protection functions | Overload and short-circuit protection |
| Additional function | Circuit switching and isolation in accordance with manufacturer requirements |
| Product family standard | IEC/EN 60947-2 |
The ABB EPX-XT4S-TM1004 is a 100 A four-pole thermal-magnetic moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for compatible ABB Protecta Power distribution boards and commercial or industrial electrical panels.
The EPX-XT4S-TM1004 has a rated current of 100 A. This is the nominal current rating of the circuit breaker and should be considered alongside its thermal protection characteristics, conductor ratings and installation conditions.
The EPX-XT4S-TM1004 has a specified 50 kA short-circuit breaking capacity. The applicable operating voltage and manufacturer short-circuit performance conditions must be checked against the prospective fault current at the installation location.
TMA identifies a thermal-magnetic trip unit combining thermal overload protection with magnetic short-circuit protection. The thermal mechanism responds to sustained excessive current, while the magnetic mechanism provides rapid interruption during short-circuit conditions.
ABB TMA thermal-magnetic circuit breakers provide protection adjustment facilities according to their specific trip unit configurations. The exact thermal and magnetic adjustment ranges for the EPX-XT4S-TM1004 should be confirmed from the supplied device's markings and manufacturer technical documentation before commissioning.
The four-pole configuration allows coordinated switching of three phase conductors and a neutral conductor. It is suitable for appropriately designed three-phase electrical distribution systems requiring four-pole switching and isolation. The neutral pole's protection characteristics should be verified for the supplied breaker configuration.
XT4N and XT4S identify different short-circuit performance versions within the ABB SACE Tmax XT4 family. The corresponding ABB Protecta Power XT4N devices are specified at 36 kA, while XT4S versions are specified at 50 kA. Selection should be based on the prospective fault current and applicable operating voltage.
Yes. The EPX-XT4S-TM1004 belongs to the ABB Protecta Power Devices range and is intended for integration into compatible distribution assemblies. The correct XT4 mounting arrangement, electrical connections, enclosure compatibility and protection settings should be verified before installation.
ABB SACE Tmax XT moulded case circuit breakers provide established protection technology for commercial and industrial electrical distribution, combining robust construction, dependable thermal-magnetic operation and substantial short-circuit interruption capability for modern low-voltage power systems.